User manual ACR ELECTRONICS RCL-100 SEARCHLIGHT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACR ELECTRONICS RCL-100 SEARCHLIGHT. We hope that this ACR ELECTRONICS RCL-100 SEARCHLIGHT user guide will be useful to you.


ACR ELECTRONICS RCL-100 SEARCHLIGHT : Download the complete user guide (529 Ko)

Manual abstract: user guide ACR ELECTRONICS RCL-100 SEARCHLIGHT

Detailed instructions for use are in the User's Guide.

[. . . ] The RCL-100D Searchlight System contains a narrow beam searchlight that produces 200, 000 peak candle power by combining two 55W halogen lamps with our unique optical quality parabolic reflectors. All functions of the Searchlight can be electrically operated by remote control from the pilot area of the vessel using the URP-102 Point PadTM, URC-102 Master Controller, and interconnect cable supplied with the RCL-100D. Searchlights equipped with the URC-102 Master Controller now have ACR's unique XRCiZ feature. The XRCiZ feature routinely operates all moving parts in the Searchlight to keep the motors and drive mechanism freely running. 3. 0 SEARCHLIGHT The sleek design and modern construction of the Searchlight body makes it attractive for recreational and commercial vessels. [. . . ] NOTE: The URP-102 Point PadTM is not recommended for use with the first generation URC100 Master Controllers. 3 Y1-03-0138 Rev. K URC-102 Master Controller Unit RG-59 Coaxial Cable Fuse URC-102 Master Controller Unit RG-59 Coaxial Cable Fuse URP-102 Point Pad "T" Conn. or Splitter RG-59 Coaxial Cable Power Source Power Source RG-59 Coaxial Cable URP-102 Point Pad URP-102 Point Pad Single Point PadTM Multiple Point PadsTM FIGURE 2: POINT PADTM CONNECTION BLOCK DIAGRAM 4 Y1-03-0138 Rev. K URP-102 Point Pad Functions · · · · · · · Press the ON/OFF button to turn the lights ON or OFF. Press the SPEED button to toggle between High and Low rotation speeds. Press the Right or Left Arrows to rotate the Searchlight in that direction. To activate the XRCiZ feature, press and hold the ON/OFF button for greater than 5 seconds. To deactivate the XRCiZ feature, Press and hold the ON/OFF button for greater than 5 seconds. An LED blinking Red / Green indicates that the XRCiZ feature is now "exercising" the Searchlight. NOTE: XRCiZ Feature is only available when paired with a URC-102 Master Controller. FIGURE 3: URP-102 POINT PADTM FUNCTIONS 5 Y1-03-0138 Rev. K FIGURE 4: URP-102 POINT PADTM SURFACE MOUNT CASE 6 Y1-03-0138 Rev. J FIGURE 5: URP-102 POINT PADTM FLUSH MOUNT CASE 7 Y1-03-0138 Rev. J FIGURE 6: URP-102 POINT PADTM Surface Mount Case with gasket and Flush Mount Case with gasket 8 Y1-03-0138 Rev. J 6. 0 URC-102 MASTER CONTROLLER Mounting The Master Controller can be mounted in any position near the Searchlight that is protected from the weather. Check in advance that the coax cable from the Point PadTM and the wiring harness from the Searchlight can be routed to this location. The Master Controller is supplied with an in-line fuseholder on the Orange power lead. Master Controller Wire Orange Blue Yellow Green Red White Black Brown Searchlight Cable Wire Power Source Lead +12 VDC or +24 VDC** Ground Yellow Green Red White Black Brown Table 1 ** NOTE: This wire MUST be fused with a 15 amp fuse in the Master Controller's in-line fuseholder. Wiring to Searchlight The RCL-100 Searchlight is supplied with a 15 foot integral wire harness. This wire harness is cut to this length specifically to allow for a voltage drop. Any extra length of wire harness should be loosely coiled in a convenient place. For best performance, the controller should be attached to the end of the 15' Searchlight wire harness. If you must lengthen the wire harness, use heavy duty wire to minimize the voltage drop. [. . . ] 1930. 3 - RCL-100D 12 V Searchlight Installation Kit includes: Description Searchlight, RCL-100D, 12 V Kit, Nylon Washers (4) Connector, "F" Cable, Coaxial Master Controller, URC-102 Connector, "In-Line" Point PadTM, URP-102 with Surface Mount Case Case, Flush Mount Gasket, Surface Mount Gasket, Flush Mount U Clamp Nuts, Nylon-lock Washers Warranty Card Product Support Manual Mounting Templates Quantity 1 1 2 15' 1 8 1 1 1 1 2 2 2 1 1 1 ACR Part Number A3-06-1106-3 A3-06-1940 A1-03-0220 A2-07-0002-6 A3-06-2231 A1-03-0222 A3-06-2230 A1-18-1875-2 A1-25-0140-1 A1-25-0140-2 A1-17-1366 A1-05-0776 A1-05-0777 A1-20-1019 Y1-03-0138 Y1-03-0138-1 PRODUCT NO. 1931. 3 - RCL-100D 24 V Searchlight Installation Kit includes: 15 Y1-03-0138 Rev. K Description Searchlight, RCL-100D, 24 V Kit, Nylon Washers (4) Connector, "F" Cable, Coaxial Master Controller, URC-102 Connector, "In-Line" Point PadTM, URP-102 with Surface Mount Case Case, Flush Mount Gasket, Surface Mount Gasket, Flush Mount U Clamp Nuts, Nylon-lock Washers Warranty Card Product Support Manual Mounting Templates Quantity 1 1 2 15' 1 8 1 1 1 1 2 2 2 1 1 1 ACR Part Number A3-06-1106-4 A3-06-1940 A1-03-0220 A2-07-0002-6 A3-06-2231 A1-03-0222 A3-06-2230 A1-18-1875-2 A1-25-0140-1 A1-25-0140-2 A1-17-1366 A1-05-0776 A1-05-0777 A1-20-1019 Y1-03-0138 Y1-03-0138-1 10. 0 REMOTE CONTROL SYSTEM COMPONENTS PRODUCT NO. 1927. 3 - URC-102 Master Controller Installation Kit includes: Description Master Controller, URC-102 Connector, "In-Line" Instruction Sheet, Master Controller Quantity 1 8 1 ACR Part Number A3-06-2231 A1-03-0222 Y1-06-0178 PRODUCT NO. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACR ELECTRONICS RCL-100 SEARCHLIGHT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ACR ELECTRONICS RCL-100 SEARCHLIGHT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.