If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX E36DF76PSS INSTALL. We hope that this AEG-ELECTROLUX E36DF76PSS INSTALL user guide will be useful to you.
Manual abstract: user guide AEG-ELECTROLUX E36DF76PSS INSTALL
Detailed instructions for use are in the User's Guide.
[. . . ] Installation Instructions
Dual Fuel Ranges
E30DF74EPS
E36DF76EPS
E48DF76EPS
5995447082
2 Safety
IMPORTANT SAFETY INSTRUCTIONS
Safety Precautions
Do not attempt to install or operate your unit until you have read the safety precautions in this manual. Safety items throughout this manual are labeled with a Warning or Caution based on the risk type.
Definitions
This is the safety alert symbol. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION CA UTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION CA UTION
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
IMPORT IMPOR TANT
Indicates installation, operation or maintenance information which is important but not hazard related.
Safety
SAFETY PRECAUTIONS
WARNING
· · Read all instructions before using the appliance. Improper installation, adjustment, alteration, service, or maintenance can cause personal injury or property damage. [. . . ] Such use may result in fire, electrical shock, or other personal injury. A fuse in the neutral or ground circuit may result in an electrical shock hazard.
19
· ·
Grounding Instructions
This appliance must be electrically grounded. With the range positioned directly in front of the cabinet cutout, feed the appliance conduit to the electrical junction box. Then, depending upon local codes, utilize one of the following techniques to connect the appliance to the electrical power supply: Connecting to a Four-Wire Electrical System 1. Connect the white appliance wire to the neutral (white) supply wire in the junction Figure 14 box. Connect the black appliance wire to the black (L1) power supply wire in the junction box. Connect the red appliance wire to the red (L2) power supply wire in the junction box. Connect the green appliance wire to the green house grounding wire in the junction box.
Cable from power supply Junction box
RED RED GREEN GREEN
WHITE WHITE BLACK BLACK Wire nut (4 places)
Conduit from appliance
Connecting the appliance to a four-wire power supply
20 Installation
WARNING
Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.
Connecting the Green Appliance Wire to the Neutral (White) Supply Wire Where Local Codes Permit
1 2 3 Connect the green and white appliance wires to the neutral (white) supply wire in the junction box. Connect the black appliance wire to the black (L1) power supply wire in the junction box. Connect the red appliance wire to the red (L2) power supply wire in the junction box.
Figure 15
Cable from power supply Junction box
RED RED
GREEN WHITE WHITE BLACK BLACK Wire nut (3 places)
Conduit from appliance
Connecting the appliance to a three-wire power supply
Installation
21
Connecting the Green Appliance Wire to a Grounded Supply Wire or a Grounded Cold Water Pipe Where Local Codes Permit.
1 2 3 4 5 6 Separate the green and white appliance wires. Connect the white appliance wire to the neutral (white) supply wire in the junction box. Connect the black appliance wire to the black (L1) power supply wire in the junction box. Connect the red appliance wire to the red (L2) power supply wire in the junction box. Connect the green appliance wire to a grounded supply wire in the junction box or to a grounded cold water pipe. If connecting to a grounded cold water pipe, a separate copper grounding wire (No. 10 minimum) must be connected to a grounded cold water pipe by means of a clamp and then to an external grounding connector screw.
WARNING
· · · Do not ground the appliance to a gas supply pipe or hot water pipe. Do not turn on power to the appliance until the range is permanently grounded. A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. 4 copper wire securely clamped to bare metal at both ends.
Figure 16
Cable from power supply Junction box Separate No. 4 copper wire
Meter
RED RED GREEN GREEN
WHITE WHITE BLACK BLACK
Clamp must be tight on pipe Wire nut (4 places)
Metal water pipe
Clamps Bare metal
Conduit from appliance
Connecting the appliance ground to a grounded junction box wire or grounded cold water pipe
22 Installation
MAKING THE GAS CONNECTION
Before sliding the range into the cabinet, connect a flexible gas connector to the gas shut-off valve previously installed on the stub out. Connect the flex connector to the pipe fitting at the right rear of the range.
WARNING
· · · Do not apply excessive pressure when tightening gas connections and fittings. Do not use teflon tape or plumber's putty on gas flex line connections. [. . . ] 8-8 Turn off the burner and the gas supply valve.
8-1 Connect the U-tube manometer to the LPG supply line. 8-2 With electrical power to the range disconnected, open the LPG supply valve. 8-3 Verify that the pressure is above 11 inches water column (WC) and below ½ PSI. Connect the range to the LPG supply line.
Place end of tube over main orifice
Figure 8-1 Pressure Test Set-up
STEP 9
Adjust Air Shutter Gaps
9-6 Hold the shutter connector with the 8" adjustable wrench. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX E36DF76PSS INSTALL
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX E36DF76PSS INSTALL will begin.