User manual AMX MVP-WDS WALL DOCKING STATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AMX MVP-WDS WALL DOCKING STATION. We hope that this AMX MVP-WDS WALL DOCKING STATION user guide will be useful to you.


AMX MVP-WDS WALL DOCKING STATION : Download the complete user guide (1197 Ko)

Manual abstract: user guide AMX MVP-WDS WALL DOCKING STATION

Detailed instructions for use are in the User's Guide.

[. . . ] Operation/Reference Guide MVP-WDS Wall Docking Station for MVP-7500/8400 Modero® ViewPoint® Wireless Touch Panels Touch Panels & Accessories Last Revised: 10/06/2006 AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] Carefully insert the main unit into the cutout until the Mounting Tabs on the MVP-WDS lie flush against the wall (FIG. Insert and secure four #4-40 Mounting Screws (not included) into their corresponding holes located along the sides of the WDS (using a grounded Phillips-head screwdriver) until the WDS is secured and is flush against the wall. Follow the steps outlined in the Replacing the Faceplate on the MVP-WDS section on page 13 to angle the MVP Support Cradle forward and re-install the faceplate. Flat surface (can include a wall, podium, or other level surface) Install the four #4-40 mounting screws into the four holes (screws not included) Attachment is done along the edges of the cutout Faceplate security screws (2) Die Cut Foam covers (2) Mounting Tab A - Faceplate (bezel) FIG. 13 MVP-WDS installation configuration for solid surfaces B - MVP-WDS (Main unit) 12 MVP-WDS Wall Docking Station for MVP Panels MVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box Replacing the Faceplate on the MVP-WDS 1. Temporarily apply power to the MVP-WDS by connecting the terminal end of the power cable to the power supply. Press the Cradle Activation Pushbutton (located inside the MVP-WDS battery compartment, next to the battery pins in Battery Slot #2 - see FIG. Temporarily remove power from the MVP-WDS to maintain the support cradle at this angle and keep it from retracting back into the MVP-WDS. Slide the Faceplate over the angled Support Cradle, toward the Security Release pushbutton's circuit board on the MVP-WDS (FIG. Gently press the faceplate down and under the Security Latch until it rests against the Mounting Tabs of the MVP-WDS main unit. Be sure to snap the Faceplate Connectors back into their respective Latches (located along the bottom rim of the faceplate - see FIG. Verify that the Security Release Pushbutton is properly aligned over it's LEDs and circuit board on the MVP-WDS main unit. Verify that the two faceplate security screw holes on both the Faceplate and the main MVP-WDS unit are properly aligned. 6. Insert and secure the two #6-32 Faceplate Security Screws into the top rim of the Faceplate using a grounded Phillips-head screwdriver. Apply power to the MVP-WDS by connecting the terminal end of the power cable to the power supply. Press the Cradle Activation pushbutton to cause the MVP Support Cradle to angle backwards and lie flush against the main unit. Remove the two adhesive plastic Die Cut Foam covers (60-5965-47) from the strip included within the Installation Kit bag. Adhere these two plastic Die Cut Foam covers into the two notches where the Faceplate Security Screws are located. Refer to the Securing an MVP Panel to an MVP-WDS section on page 15 and Removing an MVP Panel from an MVP-WDS section on page 16. Connecting a Power Supply The MVP-WDS Docking Station receives power from a 12-VDC compliant power supply using a 2-pin 3. 5 mm mini-Phoenix connector. Static electricity can damage electronic circuitry. Before touching the unit, discharge any accumulated static electricity from your body by touching a grounded metal object. Powering the MVP-WDS The MVP-WDS uses a 12-VDC compliant power supply (not included) to provide power to the MVP panel, while charging internal batteries. Once MVP batteries are fully charged, the MVP-WDS begins charging MVP-BP batteries inserted within its battery compartments. 1. Connect the terminal end of the power supply to the rear PWR connector on the WDS. Provide power to the MVP-WDS by connecting the AC power cord to an external power source. MVP-WDS Wall Docking Station for MVP Panels 13 MVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box Initially, both blue LEDs illuminate and remain dim (indicating that the power is being supplied to the MVP-WDS). Using the 3. 5mm mini-Phoenix Connector for Power To use the 2-pin 3. 5 mm mini-Phoenix connector for use with a 12 VDC-compliant power supply, the incoming PWR and GND wires from the external source must be connected to their corresponding locations on the connector (FIG. 14 NetLinx power connector wiring diagram PWR + GND Power Supply Verify that the power supply is not receiving power. 1. Insert the PWR and GND wires on the terminal end of the 2-pin 3. 5 mm mini-Phoenix cable. [. . . ] Verify you have downloaded the latest firmware file from www. amx. com and then save the Kit file to your computer. Step 2: Upgrade the Docking Station firmware via USB 1. Prepare NetLinx Studio for communication to the panel via a Virtual Master. Refer to the MVP-7500/8400 Operation/Reference Guide (available online at www. amx. com) for information on configuring communications on the panel. 3. After the Communication Verification dialog window verifies active communication between the Virtual Master and the panel, click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. Right-click on the System entry and select Refresh System to re-populate the list. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX MVP-WDS WALL DOCKING STATION




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX MVP-WDS WALL DOCKING STATION will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.