User manual ARTHUR MARTIN 34942G-M
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ARTHUR MARTIN 34942G-M. We hope that this ARTHUR MARTIN 34942G-M user guide will be useful to you.
Manual abstract: user guide ARTHUR MARTIN 34942G-M
Detailed instructions for use are in the User's Guide.
[. . . ] 34942G
Gas hob
Operating Instructions
GB
Important Safety Information
You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 350 350
Installation
This hob must be installed by qualified personnel, according to the manufacturer's instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. Ensure that the gas and electrical supply complies with the type stated on the rating plate, located near the gas supply pipe. [. . . ] Should the hob top become heavily soiled, it is recommended that a cleaning product such as Hob Brite or Bar Keepers Friend is used.
Pan Supports
When washing the pan supports by hand, take care when drying them as the enamelling process occasionally leaves rough edges. If necessary, remove stubborn stains using a paste cleaner.
The Burners
The burner caps and crowns can be removed for cleaning. Wash the burner caps and crowns using hot soapy water, and remove marks with a mild paste cleaner. A well moistened soap impregnated steel wool pad can be used with caution, if the marks are particularly difficult to remove. After cleaning, be sure to wipe dry with a soft cloth.
8
Something Not Working?
If the hob is not working correctly, please carry out the following checks before contacting your local Service Force Centre. SYMPTOM There is no spark when lighting the gas SOLUTION Check that the unit is plugged in and the electrical supply is switched on Check that the RCCB has not tripped (if fitted) Check the mains fuse has not blown Check the burner cap and crown have been replaced correctly, e. g. Check the main jet is not blocked and the burner crown is clear of food particles. after cleaning.
The gas ring burns unevenly
If after all these checks, your hob still does not operate correctly, contact your local Service Force Centre. Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.
9
Service and Spare Parts
If you require spare parts or an engineer contact your local Service Force Centre by telephoning:
0870 5 929 929
Your call will be routed to your local Service Force Centre. For the address of your local Service Force Centre and further information about Service Force, please visit the website at www. serviceforce. co. uk When you contact the Service Centre, they will need the following information: 1. · Appliances found to be in use within a commercial environment, plus those which are subject to rental agreements. · Products of AEG-Electrolux manufacture which are not marketed by AEG-Electrolux.
European Guarantee
If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications:
· · · · · ·
The guarantee starts from the date you first purchased your product. The guarantee is for the same period and to the same extent for labour and parts as exists in the new country of use for this brand or range of products. This guarantee relates to you and cannot be transferred to another user. Your new home is within the European Community (EC) or European Free Trade Area. The product is installed and used in accordance with our instructions and is only used domestically, i. e. The product is installed taking into account regulations in your new country.
Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Germany Italy Sweden UK Senlis Nürnberg Pordenone Stockholm Slough +33 +49 +39 +46 +44 (0)3 44 62 29 29 (0)800 234 7378 (0)800 117511 (0)8 672 53 60 (0)1753 219899
11
Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS Width: Depth: Height: Weight: 860 mm 500 mm 88 mm 16 Kg
CUT OUT DIMENSIONS
Width: 830 mm Depth: 470 mm Thickness: 30 mm
SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V 50 Hz, 220 V 60 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. HEAT INPUT Rear Left Burner (semi rapid) Front Left Burner (rapid) Central Burner (triple-crown) 2. 0 kW (6824 BTU/HR) 3. 0 kW Natural Gas (10236 BTU/HR) 2. 8 kW L. P. G. (9554 BTU/HR) 4, 0 kW (13652 BTU/HR)
Rear Right Burner (semi rapid) 2. 0 kW (6824 BTU/HR) Front Right Burner (auxiliary) APPLIANCE CLASS APPLIANCE CATEGORY GAS SUPPLY 1. 0 kW (3412 BTU/HR) 3 II2H3+ Natural gas G20 / 20 mbar
12
Instructions for the Installer
BURNER
TYPE OF GAS
POSITION NOMINAL THERMAL POWER (kW)
RAPID (large) MAX MIN
SEMI-RAPID A U X I L I A R Y (medium) (small) MAX MIN MAX MIN
TRIPLE CROWN MAX MIN
NATURAL GAS NOMINAL FLOW 20 mbar VALUE = RATE (m3/h) 37. 78 MJ/m3 Ws - 50. 7 MJ/ m3 NOZZLE REFERENCE (1/100 mm)
3. 0
0. 65
2. 0
0. 45
1. 0
0. 33
4. 0
1. 2
0. 286 0. 057 119 Adjust.
0. 190 0. 038 0. 095 0. 028 0. 381 0. 114 96 Adjust. [. . . ] longer than the phase wires.
Wiring diagram
L
220 240 1 2 3 4 0 5
1
2
N
1. IGNITOR UNIT 21
Fault Finding
Preliminary Electrical Systems Check
START Isolate appliance and carry out: A: Earth Continuity check.
Brown
Blue
Green Yellow
Blue Brown Green Yellow
NO
YES
Carry out: C: Polarity check.
Carry out: D: Resistance to Earth check.
Has inlet fuse blown?
NO
YES
Electricity supply should now be satisfactory.
PLUG (with cover removed)
Inlet wiring faulty. Rectify any fault.
SOCKET (face view)
Earth Wire Green/Yellow Neutral Wire Blue
()
FUSE
E( )
N
L
Isolate appliance and carry out: B: Insulation check. Rectify any fault including replacing fuses as necessary.
22
Fault finding
A. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ARTHUR MARTIN 34942G-M
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ARTHUR MARTIN 34942G-M will begin.