User manual BENSHAW 15KV MVRSM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BENSHAW 15KV MVRSM. We hope that this BENSHAW 15KV MVRSM user guide will be useful to you.


BENSHAW 15KV MVRSM : Download the complete user guide (855 Ko)

Manual abstract: user guide BENSHAW 15KV MVRSM

Detailed instructions for use are in the User's Guide.

[. . . ] BENSHAW REDISTART MICRO II INSTRUCTION MANUAL 15kV SERIES Solid State Motor Control Technology Publication #: 890015-06-01 The Leader In TABLE OF CONTENTS Table of Contents 1. 47 47 47 48 48 49 49 49 49 50 50 4. 5 PROGRAMMING: Starter Setup - Forward2 Profile . Ovr Cur Dl (TruTorque overcurrent trip delay) TT DCL Tim (TruTorque deceleration time) . 52 52 52 53 53 53 54 54 54 4. 8 PROGRAMMING: Motor Protection - Overload . [. . . ] This parameter should be set to a level that allows the motor to begin acceleration with a few seconds of a start command being received. The default value for initial torque is 20%. Values Default Max Torque (maximum torque) Description The maximum torque parameter sets the final level of torque that is supplied to the motor during starting. For a loaded motor, the maximum torque parameter initially should be set to 100% or greater. If the maximum torque value is set too low, the motor may not produce enough torque to reach full speed (UTS). On a lightly loaded motor this parameter may be reduced below 100% to provide for smoother starts. The default value for the maximum torque parameter is 105%. Values Default 52 4. 7 PROGRAMMING: Starter Setup - TruTorque Ramp Ramp Time Description The ramp time parameter sets the time it takes for the commanded torque to go from the Initial Torque Setting to the Maximum Torque Setting. If the ramp time expires before the motor reaches full speed the starter will maintain the set Maximum Torque level until either the motor reaches full speed, the stall (UTS) timer expires, or the motor thermal overload trips. It is not the same ramp time parameter that is used for current ramp profile starts. Note: Setting the ramp time to a specific value does not necessarily mean that the motor will take this time to accelerate to full speed. The motor and load may achieve full speed before the ramp time expires if the application does not require the set ramp time and maximum torque to reach full speed. Alternatively, the motor and load may take longer than the set ramp time to achieve full speed. Values Default The TruTorque ramp time is adjustable from 0 to 120 seconds in 1 second intervals. The default value for the TruTorque ramp time is 15 seconds. TT Over Cu (TruTorque overcurrent trip) Description The TruTorque overcurrent trip parameter is set as a percentage of FLA. If the motor current remains above this level for longer than the delay time the starter will trip. In order to protect applications such as pumps from water hammer when a fault does occur a normal deceleration profile will occur to "gracefully" shut down the system before the TruTorque Overcurrent Fault is displayed and the starter is disabled. Note: The TruTorque Overcurrent Trip only operates during TruTorque ramping before the starter has indicated an up-to-speed condition. If overcurrent protection is desired after the motor has come up to speed the Over Current parameter under the Motor Protection menu must be used. Values The TruTorque overcurrent can be set to Off or from 100% to 800% of FLA in 1% increments. The default value for the TruTorque Overcurrent parameter is Off Default Ovr Cur Dl (TruTorque overcurrent trip delay) Description The TruTorque overcurrent trip delay parameter sets the time that the motor current must exceed the TruTorque Overcurrent Trip setting, while the starter is ramping, before a trip will occur. The TruTorque overcurrent delay parameter can be set from 0. 1 to 90. 0 seconds in 0. 1 second intervals. The default value for the TruTorque overcurrent delay parameter is 0. 1 seconds. Values Default 53 4. 7 PROGRAMMING: Starter Setup - TruTorque Ramp TT DCL Tim (TruTorque deceleration time) Description The TruTorque deceleration time sets how quickly the motor decelerates. To make the motor decelerate at a slower rate increase this time or to make the motor stop quicker decrease this time. [. . . ] ONLY) 1 2 3 4 5 6 7 8 1 2 SW1 SW2 (RIGHT - ON) TBP12 SCR GATE 6 TBP4 CURRENT TRANSFORMERS 1 2 3 TBP13 TACH. INPUT 105 5. 1 DRAWINGS RediStart Micro II Four (4) Relay Card Layout TB2 RELAY OUTPUTS 1 24 TB1 CARD POWER 1 2 J1 RIBBON CABLE CONNECTOR RediStart Micro II Seven (7) Relay Card Layout K1 Relay 1 2 3 K2 Relay 4 5 6 K3 Relay 7 8 9 K4 Relay 10 11 12 K5 Relay 13 14 15 K6 Relay 16 17 18 K7 Relay 19 20 21 K1 K2 K3 K4 K5 K6 K7 HOT 1 2 3 4 NEUTRAL FU1 J1 TB3 120Vac Connector J1 Ribbon Cable Connector 106 5. 1 DRAWINGS RediStart Micro II RS-232 Communications Card Layout RECEIVE TRANSMIT DEVICE ENABLE RIBBON CABLE CONNECTOR LED4 LED3 SP DE LED2 TXD LED1 RXD RS-232 IC RS232 CARD BENSHAW INC. PC-1362 REV 1 BIPCMCOMS J2 TB1 TX/RXGND TX/RX+ RS-232 CONNECTORS RediStart Micro II RS-485 Communications Card Layout RECEIVE TRANSMIT DEVICE ENABLE RIBBON CABLE CONNECTOR LED3 DE LED2 TXD LED1 RXD RS485 CARD RS-485 IC BENSHAW INC. PC-1362 REV 1 BIPCMCOMS TB1 J3 TX/RX+ GND TX/RXRS-485 CONNECTORS 107 5. 1 DRAWINGS RediStart Micro II Reversing Card Layout TB3 SCR GATE 1A 1 2 TB4 SCR GATE 4A 1 2 TB5 SCR GATE 3A 1 2 TB6 SCR GATE 6A 1 2 TB2 GATE POWER 1 2 4 3 2 1 TB1 GATE SIGNALS Modbus Master Card (for Remote RTD Module) 24VDC FROM POWER CARD J3 Gnd+24V 24VDC POWER SUPPLY Com +24V J8 DE TxD RxD REMOTE RTD MODULE CONNECTOR A B Com Shield J6 D4 D5 D6 J7 CPU J1 Display J2 U3 RECEIVE TRANSMIT DEVICE ENABLE U6 CPU RIBBON CABLE CONNECTOR J5 U5 U7 DISPLAY RIBBON CABLE CONNECTOR 810007 02-00 U1 U4 D3 LED1 D2 LED2 UJ1 UJ2 VALID SLAVE RESPONSE STATUS 108 5. 1 DRAWINGS RediStart Micro II Display Cut-out MICRO DISPLAY CUT-OUT TEMPLATE (ACTUAL SIZE) CUT-OUT SIZE: 5-3/8" x 2-5/8" HOLE PATTERN: 5-11/16" x 2-15/16" HOLE SIZE: 3/16" 109 5. 1 DRAWINGS 110 6. PARAMETER LIST 6. 1 Parameter List RediStart Micro II Parameter List General The following pages list the menu parameters for the RediStart Micro II. The list gives the page number where information on the parameter can be found. The list can also be used to record the values that are programmed into the RediStart Micro II for the installation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW 15KV MVRSM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW 15KV MVRSM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.