User manual DOMETIC NDR1062 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DOMETIC NDR1062. We hope that this DOMETIC NDR1062 user guide will be useful to you.


DOMETIC NDR1062 INSTALLATION: Download the complete user guide (380 Ko)

You may also download the following manuals related to this product:

   DOMETIC NDR1062 PARTS LIST (205 ko)

Manual abstract: user guide DOMETIC NDR1062INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] ® INSTALLATION AND OPERATING INSTRUCTIONS REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION NDR1062 Contents: Installation Operating Instructions Maintenance & Service Page 4 8 12 FOR YOUR SAFETY If you smell gas: 1. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information consult a qualified installer, service agency or the gas supplier. Pour votre sécurité Si vous sentez une odeur de gaz: 1. [. . . ] GAS operation may be reset by pressing the main power ON/OFF button (1) to the OFF then ON position. Press the TEMPERATURE SELECTOR button (3) until the lamp at the desired position is illuminated. TO SHUT OFF THE REFRIGERATOR The refrigerator may be shut off while in any mode of operation by pressing the main power ON/OFF button to the UP (OFF) position. This shuts off all DC power to the refrigerator, including the interior light. GAS MODE 1. Press the AUTO/GAS mode selector button (2) to turn OFF the Auto lamp (A). Within 45 seconds the burner should be ignited and operating normally. On the initial refrigerator start-up it may take longer than 45 seconds to allow air to be purged from the gas line. If the gas does not ignite within 45 seconds the CHECK indicator lamp (D) will illuminate and the GAS mode indicator lamp (C) will go off. To reset when the CHECK indicator lamp (D) is illuminated, press the main power ON/OFF button (1) to the OFF and then ON position. NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminated after several tries. Press the TEMPERATURE SELECTOR button (3) until the lamp at the desired position is illuminated. 9 DISPLAY PANEL A ON OFF AUTO AC GAS D COLD CHECK 1 2 3 4 5 COLDEST 1 2 3 B C E DESCRIPTION OF OPERATING MODES AUTO MODE When operating in the AUTO mode, the AUTO mode indicator lamp (A) will illuminate. The control system will automatically select between AC and GAS operation with AC having priority over GAS. Either the AC indicator lamp (B) or the GAS indicator lamp (C) will illuminate depending on the energy source selected by the control system. If the control system is operating with AC energy and it then becomes unavailable, the system will automatically switch to GAS. As soon as AC becomes available again the control will switch back to AC regardless of the status of GAS operation. LIMP MODE OF OPERATION This control system contains a feature where it will continue to operate the cooling system in the event of a failure of a major operating component. If for some reason the display module becomes non functional, the control system will revert to full automatic operation selecting the best energy source available with AC, GAS priority. The temperature of the refrigerator will be maintained at the MID position within normal temperature tolerances. The power module will continually attempt to reestablish operation of the display module. The second limp mode of operation will execute when a failure of the temperature sensing device or associated electronic circuitry occurs. If this should occur, the control system will operate on the energy source selected via the control panel. The refrigerator will continue to operate in this mode indefinitely or until a new sensor is installed and the system is reset. GAS MODE When operating in the GAS mode, the AUTO mode indicator lamp (A) will be off and the GAS mode indicator lamp (C) will be illuminated. The control system will activate the ignition system and will make three attempt to light the burner for a period of approximately 45 seconds with two minutes interval. If unsuccessful, the CHECK indicator lamp (D) will illuminate and the GAS mode indicator lamp (C) will turn off. [. . . ] Turn on manual gas shutoff valve and check all fittings for leaks with soapy water. Connect 120 volt power cord to the outlet and reconnect or turn on the 12 volt DC power. Wear gloves as protection against hot lamp, broken glass and as protection of the new lamp. Refrigerator The lamp is located at the top of the refrigerator compartment. To replace the lamp proceed as follows: · remove the lamp cover by pressing in with the thumb on the side of the lamp cover. Clear blue color of flame · with gloves, pull out the lamp from the socket and FIG. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC NDR1062




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC NDR1062 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.