User manual DSC PC1000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DSC PC1000. We hope that this DSC PC1000 user guide will be useful to you.


DSC PC1000 : Download the complete user guide (1196 Ko)

Manual abstract: user guide DSC PC1000

Detailed instructions for use are in the User's Guide.

[. . . ] This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Re-orient the receiving antenna. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. [. . . ] However, these codes can only program additional codes which have equal or lesser attributes. Once programmed, the Supervisor Codes receive the Master Code's attributes. Duress Codes (Access Codes 33 & 34) - Duress codes 33 and 34 are standard User Codes that will transmit the Duress Reporting Code whenever the code is entered to perform any function on the system. NOTE: Duress codes are not valid when entering [, ][5], [, ][6] or [, ][8] sections. NOTE: Duress codes cannot be programmed as a duplicate or as a "Code + 1". User Code Attributes 1. The default attributes of a new code will be the attributes of the code used to enter whether it is a new code or an existing code being programmed. System Master (Code 40) has Partition Access for all partitions, as well as Attributes 3-4 ON by default. Inherent Attributes (all codes except installer and maintenance) Arm / Disarm - Any Access Code with Partition Access enabled will be valid for arming and disarming that partition. Command Outputs ([, ][7][1], [, ][7][2], [, ][7][3], and [, ][7][4]) - If these outputs require Access Code entry, any Access Code with Partition Access will be valid for performing the [, ][7][1-4][Access Code] functions on that partition. Programmable Attributes ([, ][5][Master/Supervisor Code][9][Code]) 1. 8. For Future Use For Future Use Zone Bypassing Enabled ESCORT Access Downlook Remote Trigger to Phone Number 1 Downlook Remote Trigger to Phone Number 2 Bell Squawk upon Arming/Disarming One Time Use Code NOTE: Attributes 5 and 6 cannot be enabled on the same access code. 12 Bell Squawk Attribute This attribute is used to determine whether an access code should generate an arming/disarming Bell Squawk upon entry of the code for Away arming. The Wireless Keys with access codes associated with them may generate Arming/Disarming Bell squawks. If desired, this option may be used with codes that are manually entered. [5] Enable DLS / Allow System Service If enabled, the installer will be able to access Installer Programming by DLS. In case of DLS access this provides a window where rings will be detected by the panel. The DLS window will remain open for 6hrs, during which time the installer will be able to enter DLS an unlimited number of times. After the 6-hr window has expired, Installer's Programming will be unavailable again until the window is re-opened. [6] User Call-up If enabled by the Installer, the panel will make 1 attempt to call the downloading computer. The downloading computer must be waiting for the panel to call before downloading can be performed. [7] Music Input On/Off If enabled on the PC5936 Audio Interface Module, the user can turn Background Music on or off. [8] User Walk Test (For Europe only) This test allows the user to verify operation of system detectors and notifies the central station that a Walk Test is in progress. Note: Fire zones, the 'F' key, and 2-wire Smoke detectors are excluded from this test. Violation of these zones will cause the system to exit the walk test then generate and transmit alarm condition to the central station. The system will notify the Central Station that a walk test has begun. [. . . ] This system has been carefully designed to be as effective as possible. There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection. Any alarm system of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons. Some but not all of these reasons may be: Inadequate Installation A security system must be installed properly in order to provide adequate protection. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC1000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC1000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.