User manual DYNACORD S 1200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DYNACORD S 1200. We hope that this DYNACORD S 1200 user guide will be useful to you.


DYNACORD S 1200 : Download the complete user guide (614 Ko)

Manual abstract: user guide DYNACORD S 1200

Detailed instructions for use are in the User's Guide.

[. . . ] The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times. Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts. Altering the circuitry without prior consent or advice is not legitimate. [. . . ] No V/I-Foldback-Limiter circuits are employed within the power amplifiers, making it possible to operate the amps on complex loads up to ±90° phase angles without a problem. The input facilities are carried out as balanced XLRF-type sockets while the Direct-Outs ­ on which the carried-through signals are present ­ come as XLRM-type connectors. Using the Input Routing-switches lets you determine if the STANDARD PRECISION SERIES amplifiers are operated in DUAL (stereo) or PARALLEL (monaural) mode; "mono-bridged" operation is also possible. These detented potentiometers guarantee precise and reliable operation. The easy readable LED display offers quick optical information on the power amplifiers' momentary operational mode. For each channel individually the display shows whether they are operational, a signal is present at the outputs, when the limiters are activated, and whether one of the protection circuits has been engaged or not. The power outputs CANNEL A, CHANNEL B and BRIDGED OUT are carried out as Speakon connectors. A ground-lift switch that separates the enclosure from the appliance's ground potential and therefore helps to eliminate ground noise loops and the mono bridged mode switch are also located on the rear panel. In normal operation all STANDARD PRECISION SERIES power amplifiers can be used to drive loads down to 2 ohms; in bridged mode the minimal load is 4 ohms. All amps are equipped with extremely silent running fans providing front-to-rear air circulation, guaranteeing trouble-free operation even in smaller power amplifier rack systems. Studying this owner's manual carefully will provide you with further and more detailed information about the STANDARD PRECISION SERIES power amplifiers. Thus we recommend to keep on reading, assuring you that the DYNACORD STANDARD PRECISION SERIES power amplifiers will provide you with a lot of fun and satisfaction in your work. 9 FRONT PANEL 1. LEVEL Detented potentiometers with a dB-scaling to adjust the overall amplification of the power amplifier. These controls should be set between 0 dB and ­6 dB, depending on the output of the connected equipment ­ e. The printed scale shows the actual amount of damping in the amplification of the power amplifier. 2. LIMIT This indicator lights when the amplifier enters clipping and the internal limiter is activated. Anyway, if this indicator lights continuously, reducing the overall volume is recommended to avoid that the connected loudspeaker systems are getting damaged from overload. 3. SIGNAL INDICATOR This indicator lights when an output signal is present. In case of short-circuited speaker cabling or one of the amplifier's protection functions is engaged the indicator is off, showing that there is no signal outputted. 4. PROTECT If this indicator lights during operation, one of the amp's internal protection functions against thermal overload, short-circuit, occurrence of HF or DC at the output . . . [. . . ] The regular output voltages of the power amplifiers A and B are still present at the individual output connectors CHANNEL A and CHANNEL B but in respect to the inverted phase, using these signals is not recommendable. Bridged mode operation on loads of 2 ohms is not admissible. GROUND-LIFT SWITCH The ground-lift switch is meant to help you in avoiding ground noise loops. Whenever the power amplifier is installed in a 19" rack system being operated together with other equipment, the recommended setting of the switch is the GROUNDED position. In case the power amplifier is used together with appliances that are connected to different ground potentials, the recommended setting is UNGROUNDED. 12 SPECIFICATIONS Technical Specifications: S900, S1200 Amplifier at rated conditions, both channels driven with 8 ohms loads, unless otherwise specified. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNACORD S 1200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNACORD S 1200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.