User manual FALMEC LUMEN ILOT 120

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FALMEC LUMEN ILOT 120. We hope that this FALMEC LUMEN ILOT 120 user guide will be useful to you.


FALMEC LUMEN ILOT 120 : Download the complete user guide (1370 Ko)

Manual abstract: user guide FALMEC LUMEN ILOT 120

Detailed instructions for use are in the User's Guide.

[. . . ] For best results, we suggest that you carefully follow the operating and maintenance instructions provided in this booklet; in addition, to order spare charcoal filters, use the special coupon on the cover. 12 GB INSTRUCTIONS BOOKLET WARNINGS This instruction booklet must be kept together with the appliance for future reference. If the appliance is sold or consigned to other parties, check that the booklet is supplied with it, to ensure that the new user has the correct information on the operation of the range hood and is aware of the warnings. These warnings have been provided for the your safety and the safety of others. [. . . ] The range hood should be switched on when starting to cook, and left on until the odours disappear. FIVE BUTTON CONTROL PANEL LIGHT- button Pressed: the light is on Released: the light is off MOTOR button - 1, 2, 3, OFF 1: starts the motor at minimum speed 2: starts the motor at medium speed 3: starts the motor at maximum speed OFF: stops the motor 15 2. ELECTRONIC CONTROL PANEL Light pushbutton - ON: light on (the pushbutton is lit); - OFF: light off; Pushbutton Press to reduce motor speed Speed 1, 2 and 3 are indicated by the number of LEDs that light up (excluding the light and the timer LEDs). Pushbutton + Press to increase motor speed Speed 1, 2 and 3 are indicated by the number of LEDs that light up (excluding the light and the timer LEDs). The function “desired speed” enables to start the motor at the speed that was selected before the hood was last turned off. WARNING: Install the hood away from sources of electromagnetic waves, as these could affect the correct operation of the electronic system. The maximum operating distance could be less than 5 metres in case of electromagnetic interference by other equipment. € and + pushbutton: increase/decrease speed (to start the motor press either the + or the – pushbutton). Timer and ‘filter clogged’ alarm pushbutton - This function allows the automatic turning off of the hood after running for 15 minutes at the speed previously set (the pushbutton shows a flickering light). - After about 30 hours of running the pushbutton indicates the need for washing the metal filters (the pushbutton shows a solid red light). To disable the alarm press the pushbutton for a few seconds until the red light turns off. Then turn the hood off and on again to check that the alarm has disappeared. ELECTRONIC CONTROL PANEL 1: Timer/Alarm filters The steady RED light indicates that the fat filter alarm is activated (after 30 hours), to deactivate this alarm and zero the meters, maintain the Key pressed for 3 seconds. This function can only be activated if the motor is activated and running at any velocity when the Key is pressed (either prolonged or not). This function will cause the automatic switch-off of the hood after 15 minutes. With the Timer function activated, the hood can be switched-off by the operator in any case and the function will be deactivated. A change in the velocity, with the Timer function activated, will deactivate it. 2: 1st Velocity When the LED is switched-off, non-prolonged pressing of the key will switch-on the hood at the 1st velocity and illuminate the respective LED. When the LED is switched-off and another velocity is activated, pressing the Key will imply selection of the 1st velocity, switching-on of the respective LED and switching-off of the LED associated with the velocity that was previously selected. When the LED is on, pressing the Key will imply the switching-off the LED and MOTOR. When the LED is switched-off, prolonged pressing (at least 3 seconds) of the Key will cause activation of the recirculation function. During the recirculation function (with a duration of 24 hours), the LED will flash. [. . . ] In case of fingerprint-less finish (fasteel) clean only with water and neutral soap using clean with a soft cloth, rinse and wipe dry thoroughly. Do not use products that contain abrasive substances, rough cloths or cloths specifically designed for cleaning steel. Using abrasive substances or rough cloths will inevitably damage the finish of steel. The steel surface will be irrevocably damaged if the instructions above are not complied with. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FALMEC LUMEN ILOT 120




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FALMEC LUMEN ILOT 120 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.