User manual FALMEC MIRA FASTEEL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FALMEC MIRA FASTEEL. We hope that this FALMEC MIRA FASTEEL user guide will be useful to you.


FALMEC MIRA FASTEEL : Download the complete user guide (20083 Ko)

Manual abstract: user guide FALMEC MIRA FASTEEL

Detailed instructions for use are in the User's Guide.

[. . . ] The installation kit (screws and plugs) supplied with the hood is only to be used on masonry walls: in case of installation on walls of a different material, assess other installation options keeping in mind the type of wall surface and the weight of the hood (indicated on page 2). Keep in mind that installations with different types of fastening systems from those supplied, or which are not compliant, can cause electrical and mechanical seal danger. Do not install the hood outdoors and do not expose it to atmospheric elements (rain, wind, etc. The electrical system to which the hood is to be connected must be in accordance with local standards and supplied with earthed connection in compliance with safety regulations in the country of use. [. . . ] pOSITIONING The minimum distance between the highest part of the cooking equipment and the lowest part of the hood is indicated in the installation instructions. Generally, when the hood is placed over gas cookers, the distance must be at least 65 cm (25. However, according to standard EN60335-2-31, the minimum distance between the cooker and lower part of the hood can be reduced to the quota reported in the installation instructions. Should the instructions for the gas cooker specify a greater distance, this must be taken into consideration. Do not install the hood outdoors and do not expose it to outdoor environment (rain, wind, etc. In this version the fumes and vapours are discharged outside through the exhaust pipe. To this end, the hood outlet fitting must be connected via a pipe, to an external output. The outlet pipe must have: · A diameter not less than that of the hood fitting. The minimum required length to avoid vibrations and reduce the suction performance of the hood. You are required to insulate the pipes if it passes through cold environments. In the presence of motors with 800m3/h or higher, a check valve is present to prevent external air flowing back. Deviation for Germany: when the kitchen hood is used at the same time as appliances that are powered by energy other than electricity, the negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar). Disconnect the equipment from electrical mains power supply before carrying out any operations on the hood. Ensure that the wires inside the hood are not disconnected or cut: in the event of damage, contact your nearest Servicing Department. Connection must be carried out in compliance with the provisions of law in force. Before connecting the hood to the electrical mains power supply, check that: · Voltage supply corresponds with what is reported on the data plate located inside the hood; · The electrical system is compliant and can withstand the load (see the technical specifications located inside the hood); · The power supply plug and cable do not come into contact with temperatures exceeding 70 °C; · The power supply system is effectively and properly connected to earth in compliance with regulations in force; · The socket used to connect the hood is within reach. in case of: · Devices fitted with cables without a plug: the type of plug to use is a ''standardised'' one. The wires must be connected as follows: yellow-green for earthing, blue for neutral and brown for the phase. Fixed equipment not provided with a power supply cable and plug, or any other device that ensures disconnection from the electrical mains, with an opening gap of the contacts that enables total disconnection in overvoltage category III conditions. Said disconnection devices must be provided in the mains power supply in compliance with installation regulations. The Manufacturer declines all responsibility for failure to comply with the safety regulations. In this model, the air passes through the charcoal filters to be purified and recycled in the environment. [. . . ] Symbolet med den overstregede affaldsspand, der er gengivet på deres apparat, betyder at produktet indgår i kategorien WEEE, dvs, "Waste Electrical and Electronic Equipment" (affald af elektriske og elektroniske produkter) hvorfor det ikke må bortskaffes sammen med dagrenovationen som almindeligt affald, men skal behandles særskilt for at kunne genanvendes, eller undergå særlig behandling for udskillelse af eventuelt skadelige dele/stoffer, der bortskaffes med respekt for miljøet. Korrekt bortskaffelse af dette produkt medvirker til at spare værdifulde resurser og undgå potentielle negative påvirkninger for folkesundheden og omgivelserne, som omvendt kan forårsages af en ukorrekt bortskaffelse af affaldet. kontakt venligst de lokale myndigheder , for at indhente yderligere oplysninger om det nærmeste indsamlingspunkt. Der kan være fastsat bøder for ukorrekt bortskaffelse af denne type affald i den nationale lovgivning. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FALMEC MIRA FASTEEL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FALMEC MIRA FASTEEL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.