User manual FALMEC STELLA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FALMEC STELLA. We hope that this FALMEC STELLA user guide will be useful to you.


FALMEC STELLA : Download the complete user guide (9149 Ko)

Manual abstract: user guide FALMEC STELLA

Detailed instructions for use are in the User's Guide.

[. . . ] EN - Preliminary operations: Cutting the plasterboard (1), inserting the supporting frame (2). EN - Preliminary operations: fixing the mandatory safety chains to the ceiling. EN - Final operations: Passing the chains through, passing the control cable through. EN - Fixing the motor (or rectangular connection) (3), electrical connection and tensioning the safety chains (4). [. . . ] Generally, when the hood is placed over gas cookers, the distance must be at least 65 cm (25. However, according to an interpretation of standard EN60335-2-31 dated 11-07-2002 of TC61 (sub-clause 7. 11), the minimum distance between the cooker and lower part of the hood can be reduced to the quota reported in the installation instructions. Should the instructions for the gas cooker specify a greater distance, this must be taken into consideration. Do not install the hood outdoors and do not expose it to outdoor environment (rain, wind, etc. Disconnect the equipment from electrical mains power supply before carrying out any operations on the hood. Ensure that the wires inside the hood are not disconnected or cut: in the event of damage, contact your nearest Servicing Department. Connection must be carried out in compliance with the provisions of law in force. Before connecting the hood to the electrical mains power supply, check that: · Voltage supply corresponds with what is reported on the data plate located inside the hood; · The electrical system is compliant and can withstand the load (see the technical specifications located inside the hood); · The power supply plug and cable do not come into contact with temperatures exceeding 70 °C; · The power supply system is effectively and properly connected to earth in compliance with regulations in force; · The socket used to connect the hood is within reach. in case of: · Devices fitted with cables without a plug: the type of plug to use is a ''stand- ardised'' one. The wires must be connected as follows: yellow-green for earthing, blue for neutral and brown for the phase. Fixed equipment not provided with a power supply cable and plug, or any other device that ensures disconnection from the electrical mains, with an opening gap of the contacts that enables total disconnection in overvoltage category III conditions. Said disconnection devices must be provided in the mains power supply in compliance with installation regulations. The Manufacturer declines all responsibility for failure to comply with the safety regulations. In this version the fumes and vapours are discharged outside through the exhaust pipe. To this end, the hood outlet fitting must be connected via a pipe, to an external output. The outlet pipe must have: · A diameter not less than that of the hood fitting. The minimum required length to avoid vibrations and reduce the suction per- formance of the hood. You are required to insulate the pipes if it passes through cold environments. In the presence of motors with 800m3/h or higher, a check valve is present to prevent external air flowing back. Deviation for Germany: when the kitchen hood is used at the same time as appliances that are powered by energy other than electricity, the negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar). hOOD WITH INTERNAL RECIRCULATION (FILTERING) In this model, the air passes through an optional filter unit in the ceiling to be purified and recycled in the environment. [. . . ] Printing, translation and reproduction, even partial, of this manual are bound by the Manufacturer's authorisation. Technical information, graphic representations and specifications in this manual are for information purposes and cannot be divulged. The Manufacturer is not responsible for any transcription or translation errors. The glass panels can only be cleaned with specific, non-corrosive or non-abrasive detergents using a soft cloth. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FALMEC STELLA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FALMEC STELLA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.