User manual FLUKE SPLT
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE SPLT. We hope that this FLUKE SPLT user guide will be useful to you.
Manual abstract: user guide FLUKE SPLT
Detailed instructions for use are in the User's Guide.
[. . . ] 100521
3152142 REV 103
Printed in the USA.
© 1998-2009 DH Instruments, a Fluke Company
TABLE OF CONTENTS
TABLE OF CONTENTS
TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II ABOUT THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 8 PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Page I
© 1998-2009 DH Instruments, a Fluke Company
SPLTTM USER'S MANUAL
TABLES
Table 1. Parts Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPLT (Overall View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PPC with SPLT and DUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Front View (Left) and Side View (Right). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
© 1998-2009 DH Instruments, a Fluke Company
Page II
ABOUT THIS MANUAL
ABOUT THIS MANUAL
Manual Conventions
(CAUTION) is used in manual to identify user warnings and cautions.
(NOTE) is used in the manual to identify operating and applications advice and additional explanations.
Page III
© 1998-2009 DH Instruments, a Fluke Company
SPLTTM USER'S MANUAL
NOTES
© 1998-2009 DH Instruments, a Fluke Company
Page IV
1. INTRODUCTION
1.
1. 1
INTRODUCTION
PRODUCT OVERVIEW
The SPLT is a free standing accessory designed to protect the PPC from liquid contamination returning from the system or device under test. The SPLT is made up of a stainless steel body with an internal X-Type coalescing filter and a bottom drain port fitting with an electrically actuated purge valve. The filter and valve assembly is installed in a mounting stand.
1. 2
SUBASSEMBLY DESCRIPTION AND LOCATION
1. Electrical Connection - Terminal block connections to PPC valve driver for activation of exhaust valve
Figure 1. SPLT (Overall View)
Page 1
© 1998-2009 DH Instruments, a Fluke Company
SPLTTM USER'S MANUAL
1. 3
SPECIFICATIONS
Pressure Connections Power Requirements Weight Dimensions Maximum Working Pressure Maximum Differential Across Filter Operational Capacity of Filter Body 1/4 in. NPT F Apply 12 V to actuate valve, 6 watts 1. 7 kg (3. 8 lb) 10 cm H x 10 cm W x 17. 5 cm D (3. 9 in. x 6. 9 in. ) 2 000 psi 80 psi 10 cc
© 1998-2009 DH Instruments, a Fluke Company
Page 2
2. PPC with SPLT and DUT
Be sure SPLT is at low point of pneumatic system. The SPLT is intended to collect and exhaust liquid contaminants that may be present in the device or system under test so that they do NOT return to the PPC. The SPLT is installed in the test connection line at a low point between PPC and the device or system under test. TeflonTM tape or another sealing material should be used to assure leak free connection of adaptors installed in the SPLT pressure connections. Proper SPLT operation is dependent on the gas flowing through it in the correct direction. Make sure to connect the SPLT to the device or system under test and the PPC following the connector port labels on the SPLT. [. . . ] Leak Check.
Page 7
© 1998-2009 DH Instruments, a Fluke Company
SPLTTM USER'S MANUAL
4. 3
· · · · · · ·
SPLT EXHAUST VALVE REMOVAL AND REPLACEMENT
See Section 4. 5. Remove fittings (3137066, 3133040) and drain tube (3232357) from exhaust valve. Install fittings (3137066, 3133040) and drain tube (3232357) onto the new exhaust valve. Leak check assembly.
Any or all of the following items may be included as part of SPLT maintenance and overhaul: · · · · · Clean or change filter (see Section 4. 1). [. . . ]