User manual GAGGENAU AH530790

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAGGENAU AH530790. We hope that this GAGGENAU AH530790 user guide will be useful to you.


GAGGENAU AH530790 : Download the complete user guide (800 Ko)

You may also download the following manuals related to this product:

   GAGGENAU AH530790 (818 ko)
   GAGGENAU AH530790 (819 ko)

Manual abstract: user guide GAGGENAU AH530790

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and assembly instructions AH 530-790 AH 530-720 Extractor hood AH 530-790 AH 530-720 Preface Safety notes 1. Important notes 1. 1 For your safety 1. 2 Operating for the first time 1. 3 About use 2. Assembly instructions 6. 1 Technical data 6. 2 Installation Page 3 Page 4-5 Page 4 Page 5 Page 5 Page 6 Page 7-9 Page 10-11 Page 12 Page13-17 Page 13 Page 14-17 1 Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: ­ A good extraction capacity with low noise values, ­ a large number of control functions, ­ optimum illumination of the cooking surface by a dimmable halogen light. [. . . ] Operation The AH 530-790 is 35 3/8 ´ ´ / 90 cm wide, and the AH 530-720 is 47 3/16 ´ ´ / 120 cm wide. After they have been pressed, all functions selection keys except 0 ("Motor off") are backlit in green. Light The lighting can be switched on or off, regardless of whether the wall extractor is in operation, by pressing the key (see Fig. When you briefly press the key, the lighting is increased up to the maximum level. You can dim the lighting to the required level by keeping the key pressed. Fig. 4 Fan levels Three fan speeds and one intensive speed are available (see Fig. You set the fan level required for each respective cooking situation by pressing the function selector keys 1, 2, 3 or Int. or or or Fig. 5 7 The Int key for the intensive level should be pressed when browning and frying in an open pan (see Fig. If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. Fig. 6 If you press the Int key while the hood is running at fan level 1, 2 or 3, the electronic control will switch back automatically to the previously selected fan level after 5 minutes (see Fig. 7 If you would like to end the intensive level before the five minutes have elapsed, press the 0 key ("Motor off") or select a different level (see Fig. You can of course switch off the hood's extraction function at any time by pressing the 0 key ("Motor off"). Fig. . 8 8 Special functions: Intensive time: You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting (see Fig. First press the required key 1, 2, 3 or Int and then press the key (see Fig. After these ten minutes, the ventilation switches off, but the lighting stays on. or or or Fig. 11 or or Interval ventilation: Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour. You can activate this function by simultaneously pressing the 0 key and, depending on the required extraction capacity, the 1, 2 or 3 key (see Fig. This mode of operation is indicated by alternating illumination of the key together with the corresponding fan level indicator. You can switch off interval ventilation by pressing the 0 key (see Fig. Cleaning and care Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to indicate that you should clean the grease filter (see Fig. The grease filter can of course be cleaned at any time, even if the grease filter saturation display should not start to flash. The stainless steel grease filters can be removed easily for cleaning (see Fig. [. . . ] Pay particular attention to ensuring that ­ the exhaust air ducts and pipes are kept as short as possible ­ the pipes are not laid at an acute angle, but as bends and that they are inserted into the shaft at an inclined upward angle and ­ there are no cross-sectional constrictions in the upward direction (this reduces the volume flow). As standard, the blow-out opening of the wall hood is in the upward direction. To pass exhaust air through the outer wall, we recommend the use of our telescopic wall box TM 150-045 (Ø 6 ´ ´ / 150 mm). condensate or rain water from an uncovered exhaust air shaft, our condensate separator RV 060-150 must be installed in the exhaust air line. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAGGENAU AH530790




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GAGGENAU AH530790 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.