User manual GAGGENAU AI201100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAGGENAU AI201100. We hope that this GAGGENAU AI201100 user guide will be useful to you.


GAGGENAU AI201100 : Download the complete user guide (824 Ko)

You may also download the following manuals related to this product:

   GAGGENAU AI201100 (826 ko)
   GAGGENAU AI201100 (825 ko)
   GAGGENAU AI201100 (828 ko)
   GAGGENAU AI201100 (827 ko)
   GAGGENAU AI201100 (830 ko)
   GAGGENAU AI201100 (835 ko)
   GAGGENAU AI201100 (827 ko)
   GAGGENAU AI201100 (826 ko)
   GAGGENAU AI201100 (831 ko)
   GAGGENAU AI201100 (825 ko)
   GAGGENAU AI201100 annexe 1 (826 ko)
   GAGGENAU AI201100 annexe 2 (826 ko)

Manual abstract: user guide GAGGENAU AI201100

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and Assembly Instructions AI 200 AI 201 AI 202 AI 203 Extractor Hood AI 200 AI 201 AI 202 AI 203 Preface 1. Important notes 1. 1 For your safety 1. 2 Operating for the first time 1. 3 About use 2. Assembly instructions 6. 1 Technical data 6. 2 Installation Page 3-4 Page 3 Page 4 Page 4 Page 5 Page 6-8 Page 9-10 Page 11 Page 12-17 Page 12 Page 12-17 1 Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: ­ a good extraction capacity with low noise values, ­ a large number of control functions, ­ optimum illumination of the cooking surface by a dimmable halogen light. [. . . ] 8 7 Special functions: Intensive time: You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting (see Fig. First press the required key 1, 2, 3 or Int and then press the key (see Fig. After these ten minutes, the ventilation switches off, but the lighting stays on. or or or Fig. 11 or or Interval ventilation: Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour. You can activate this function by simultaneously pressing the 0 key and, depending on the required extraction capacity, the 1, 2 or 3 key (see Fig. This mode of operation is indicated by alternating illumination of the key together with the corresponding fan level indicator. You can switch off interval ventilation by pressing the 0 key (see Fig. Cleaning and care Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see Fig. The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash. The stainless steel grease filters can be removed easily for cleaning (see Fig. Then pull the grease filter downwards out of the holder; repeat the operation for the other grease filters. You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65°C, where it should be supported vertically to allow food or rinsing residues to drain off. If possible, the inner parts of the housing should be wiped out in hot rinsing water when replacing the filters. Caution: when cleaning the inside of the housing, beware of protruding parts. Fig. 13 After having cleaned them, re-insert the grease filters in the extractor hood in reverse order. Important: the handles of both grease filters must be visible after assembly. Fig. Flashing of the indicating lamp goes off. 9 Cleaning the extractor hood Clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Clean the stainless-steel extractor hood (AI 200/AI 202) with stainless steel cleaner. ceramic cups) on the hood. Circulating air mode The activated charcoal filter eliminates kitchen smells in the circulating air mode. In normal use (1 to 2 hours daily), the activated charcoal filter must be replaced approximately once a year. If no activated charcoal filter is installed, kitchen smells will not be eliminated. The activated charcoal filter (KF 001-010) is available through your specialist dealer. [. . . ] Before marking the securing holes, make sure that no electricity wires or water pipes or other wires/ pipes are laid at the drilling points in the ceiling. Before installation check the enclosed wall plugs and screws are suitable for your ceiling. Using the drilling template mark the position of the screws on the ceiling. Both screws are placed in a position, in which at a later stage of the installation the key-holes of the supporting frame are found (namely back left and front right from the control panel of the hood). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAGGENAU AI201100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GAGGENAU AI201100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.