User manual GAGGENAU VG 232 AU

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAGGENAU VG 232 AU. We hope that this GAGGENAU VG 232 AU user guide will be useful to you.


GAGGENAU VG 232 AU : Download the complete user guide (703 Ko)

Manual abstract: user guide GAGGENAU VG 232 AU

Detailed instructions for use are in the User's Guide.

[. . . ] Important notes Page 5-6 1. 1 For your safety Page 5 1. 2 Operating for the first time Page 5 1. 3 About use Page 6 2. Structure and operating principle Page 7-8 2. 1 Structure Page 7 2. 2 Special accessories Page 7 2. 3 Operating principle Page 8 3. Maintenance Page 11 5. 1 General Page 11 5. 2 Remedying slight malfunctions yourself Page 11 6. Assembly instructions Page 13-18 7. 1 Important notes Page 13 7. 2 Electrical connection/gas connection Page 14-15 7. 3 Nozzle replacement Page 16-17 7. 4 Installing the appliance Page 18 1 FOR YOUR SAFETY WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. [. . . ] Tip: When buying pots, pay attention to the fact that the manufacturer frequently specifies the top pot diameter, which is generally larger than the diameter of the base. Use cooking utensils that the manufacturer states as being "suitable for gas". Preferably use the larger cooking zone for brief cooking, deep fat frying and brief frying of large quantities. Preferably use the smaller ring for soaking, warming up and keeping warm, even when large quantities are involved. 6 2. Structure and operating principle 2. 1 Structure 1 High-power burner B 10 MJ (2. 8 kW) 1 2 3 4 2 Normal burner A 6. 5 MJ (1. 8 kW) 3 Pot support 4 Control knob for the front cooking position 5 Control knob for the rear cooking position 5 Fig. 2 6 Burner cover 6 7 Burner head 8 Spark plug for automatic ignition 9 Thermal sensor for flame monitor 7 8 Fig. 3 9 2. 2 Special accessories You can order the following special accessories: ­ VV 200-000: Connecting strip ­ VD 201-010: Appliance cover (If an appliance cover is fitted, the pot support must be removed when closing. ) 7 2. 3 Operating principle The appliance features one-hand operation. That is to say, the ignition is activated when the control knob is pressed briefly. After igniting, keep the control knob pressed for around 5-8 seconds more because the heat sensor that opens the gas valve has to warm up first. The gas hob has 1 normal burner (front burner) and 1 high-intensity burner (rear burner). All burners have a thermal protection device that prevents unburned gas from escaping in the open position. Off The total rated thermal load amounts to: 16. 5 MJ (4. 6 kW) The specified rated load is defined by installation of the fixed nozzles. The gas hob is converted to a different gas type by nozzle replacement (full and low-burning nozzles) (see nozzle table on p. The symbols on the control panel mean: 0 Off High setting Low setting The flame is infinitely variable between high and low-setting. Maintenance Instructions ­ Keep appliance area clean and free from combustible materials, gasoline and other inflammable vapors and liquids. ­ Do not obstruct the flow of combustion and ventilation air. Low High Fig. 4 ­ Visually check burner flames with this pictorial representation (see figure 4). 8 3. Operation The cooking positions must only be ignited when all burner parts are fitted. Switching on: ­ Place a pot or a pan on the corresponding cooking position. ­ Fully press in the control knob for the corresponding cooking position. ­ Turn the control knob to the left to the "high" position. If the flame should not ignite within 2 to 4 seconds, turn the control knob further to the left to the "low" position and then back to the "high" position after ignition. It is often faster to ignite in the low position because the various gases have a differing ignition response. After igniting, keep the control knob pressed for around 5 - 8 seconds more because the heat sensor that opens the gas valve has to warm up first. [. . . ] For Natural Gas the regulator must be connected. 40 mm Seal A flexible connection is not permitted. Fig. 9 1/ 2" 15 7. 3 Nozzle replacement Changing over to a different gas type Only authorised specialists are permitted to change over to a different gas type. The nozzles needed for the gas type to be set are available as a conversion kit. Loads for all gases For all gas types and pressures, the rated load is achieved by installing the high and low setting nozzles for the required gas type (see nozzle table). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAGGENAU VG 232 AU




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GAGGENAU VG 232 AU will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.