User manual GAGGENAU VL431707

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAGGENAU VL431707. We hope that this GAGGENAU VL431707 user guide will be useful to you.


GAGGENAU VL431707 : Download the complete user guide (277 Ko)

You may also download the following manuals related to this product:

   GAGGENAU VL431707 (278 ko)

Manual abstract: user guide GAGGENAU VL431707

Detailed instructions for use are in the User's Guide.

[. . . ] When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: a. ) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. c. ) DO NOT USE WATER, including wet dishcloth or towels - a violent steam explosion will result. You know you have Class ABC extinguisher, and you already know how to operate it. [. . . ] If you have installed the hob extractor only on one side of the gas appliance, it is sufficient to fit one air baffle LS 330 on the side facing the extractor. No warranty claims can be lodged in the event of damage caused by failure to observe these instructions. Technical modifications reserved. 4 Operating for the first time Before operating the appliance for the first time, please pay attention to the following notes: Conscientiously read through the operating and assembly instructions before operating the appliance for the first time. Pay attention to the fact that there are accessories in the packaging!(see chapter entitled "Cleaning and care") Before operating the appliance for the first time, check that the mains connection is in proper working order. Maintenance The appliance must be disconnected from the power supply during all repair work. If the power supply is functioning correctly, but your appliance still does not work, please contact your Gaggenau dealer who will provide you with the address and telephone number of your nearest manufacturer's authorized service agent or contact Gaggenau USA on (800) 828-9165. Repairs may only be carried out by authorised technicians, in order to guarantee the safety of the appliance. Unauthorised tampering with the appliance will invalidate any warranty claims. Features Features 1 2 3 4 5 Ventilation flaps Metal grease filter Membrane key pad (VL 431 only) Clamping screw Suction extraction connection 1 2 3 4 5 Special accessories AL 400-000 Edge trim RV 050-150 Bifurcated pipe for joining 2 x DN 125 into DN 150 LS 330-000 Air baffle 6 3. Operation Note: VL 430 can only be operated in combination with VL 431. That is to say: if you press the key for level 1, both hob ventilators are operated at level 1. Switching on Press the corresponding membrane key for the required level. 1 = Low speed, the flaps open 2 = High speed = Approximately 20 minutes run-on time on level 1. Then, the hob ventilator switches off automatically and the flaps shut. Ideal for ventilating the kitchen after cooking. Switching off Press the 0 membrane key. Cleaning and care The grease filters must be cleaned on a regular basis (at the latest after 30 hours of operation). · Push the flaps towards the front and carefully lift them up on the rear. · Turn the two retaining hooks on the sides up, slightly push them together and remove the metal grease filter. You can clean the metal grease filter in a dishwasher at a maximum temperature of 130°F / 55°C. Place the grease filter in the dishwasher with the opening pointing down to ensure that no food remainders will stay on it. Insert the flap pins on the front into the hole and hook in at the rear at the correct angle. Cleaning the frame and the membrane key pad Apply commercially available window cleaning agent with a soft, moist cloth. Assembly instructions Important notes on installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. ) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. [. . . ] It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to the Installing the appliance ' 3 11/16' 1 ' 20 /16' 6 3/8' 51/2' min. 2 ' 5 6' 19 /1 ' 3 3 /16 3 ' 17 /4 5 ' 6 32 /1 7 6' 50 /1 If two Vario appliances are used, the hob ventilator must be installed between the appliances. If 4-plate hobs are used, it is recommended to place two ventilators to the left and right of the hob. If you have installed a gas appliance between the hob extractors VL 430/431, the gas hob has to be fitted with two air baffles LS 330 on the side of the hob while cooking. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAGGENAU VL431707




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GAGGENAU VL431707 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.