If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HASSELBLAD FLEXTIGHT 949. We hope that this HASSELBLAD FLEXTIGHT 949 user guide will be useful to you.
You may also download the following manuals related to this product:
HASSELBLAD FLEXTIGHT 949 (1488 ko)
HASSELBLAD FLEXTIGHT 949 (1485 ko)
HASSELBLAD FLEXTIGHT 949 (1477 ko)
HASSELBLAD FLEXTIGHT 949 (1461 ko)
HASSELBLAD FLEXTIGHT 949 DATASHEET (648 ko)
Manual abstract: user guide HASSELBLAD FLEXTIGHT 949
Detailed instructions for use are in the User's Guide.
[. . . ] is connected to power.
· Do not place your fingers or any other object into the scanner while it · Before servicing or opening the scanner, the power supply must be · Install the scanner in a location where children can not get to it. It is not sufficient simply to press the on/off button.
User's Guide - Flextight 949
Hardware Reference - Flextight 949 System Requirements
7
System Requirements
Below are the basic hardware requirements for the PC or Macintosh system to which the scanner is to be connected. For information about the processor, operating system, RAM and harddisk requirements please refer to the "Software Reference" manual, that comes with the FlexColor software.
· Screen resolution of 800 x 600 pixels with true colors (24-bits). · FireWire interface.
User's Guide - Flextight 949
English
8
Hardware Reference - Flextight 949
English
User's Guide - Flextight 949
Hardware Reference - Flextight 949 Front Panel
9
Front Panel
A
D
E F B C
Figure 1: Front panel features of Flextight 949 A Feed Table: must be in lower position for normal scanning. [. . . ] Also, no edges of the original must extend past the outer edges of the holder. · For reflectives, select the large A4/letter-size holder with the clear plastic layer. · For 35 mm slide frames use the optional 35 mm slide mount holder. This is obtained by lifting the table slightly upwards while pushing it gently into the scanner. Please note that when scanning 35 mm slide frames in the 35 mm slide mount holder it is recommended to use autofocus. continues. . .
4.
5.
User's Guide - Flextight 949
English
16
Hardware Reference - Flextight 949 Operating Instructions
English
CLOSED
HORIZONTAL
NORMAL
D A E
F G
FLEX TIG HT
à
H J
OR IGINA L HO LD ER
PATE NT
PE ND
ING
à
L
K
B
C
Figure 4: Operating the Flextight 949 scanner
User's Guide - Flextight 949
Hardware Reference - Flextight 949 Operating Instructions
17
. . . continued NOTE!Each original holder has it's own unique identification code (a combination of small rectangular holes at the holder's leading edge). These codes, combined with the scanner's ability to detect the feed table position, ensure that the scanner will not operate unless the feed table position matches the selected original holder. Place the original holder (K) with the slotted tab facing into the scanner. resolutions (in ppi) available with each of the original holders when scanning in True Resolutions mode. Original 35 mm Portrait 35 mm Landscape 45 x 60 mm Portrait 60 x 60 - 60 x 70 mm 4" x 5" Portrait A4 Portrait Table 1: True Resolutions Max. 8000 5000 4000 3200 2040 960
User's Guide - Flextight 949
English
20
Hardware Reference - Flextight 949 Calibrating the Scanner
Calibrating the Scanner
English
The scanner requires two types of calibration:
· Focus calibration adjusts the positioning of the scanners optics for
each zoom level. If your scans are coming out unfocused or at slightly the wrong size, then you may need to make a new focus calibration to adjust the zoom mechanism. The focus calibration is stored in the scanners flash PROM, so it is preserved when you move the scanner to a new computer. During calibration, the scanner scans a white target to establish the white point along the full length of the scanners CCD. The results of the white calibration scan are saved on your computers hard disk, so you must make a new white calibration if you move the scanner to a new computer. See "White Calibration for Reflectives" on page 22 for more information.
· White calibration is only required for reflective scans (it is done
Both of the calibration procedures are simple and are initiated from the FlexColor program.
User's Guide - Flextight 949
Hardware Reference - Flextight 949 Calibrating the Scanner
21
Focus Calibration
The Flextight 949 scanner uses an adjustable zoom and focus mechanism to optimize its scanning resolution for each of the original formats it can handle. If you suspect your scans are not as sharp as they should be, then you may need to calibrate your scanner. It is intended that the scanner is calibrated not more than once every three months. It is a 8 x 9 cm (3" x 3. 5") square of transparent film with a black image on it.
Focus sheet
PN:40900026, rev. 1. 10
2.
Load the sheet into the 6 x 6 original holder with the lines pointing towards the scanner (vertically). Use the scanners light table grid and the corners marked on the sheet to help align it. [. . . ] 18635445
www. hasselblad. com
Declaration of conformity
Application of Council Directives: . . . . . . . . . . . . . . . . . Standards to which Conformity is declared: EN61000-6-1 2001, EN61000-6-3 2001 and EN60950:2000.
Manufacturer: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hasselblad A/S Hejrevej 30 DK-2400 Copenhagen NV/ Denmark Type of Equipment: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Desktop CCD scanner Model name: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HASSELBLAD FLEXTIGHT 949
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HASSELBLAD FLEXTIGHT 949 will begin.