User manual KRANZLE K1050P

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KRANZLE K1050P. We hope that this KRANZLE K1050P user guide will be useful to you.


KRANZLE K1050P : Download the complete user guide (4620 Ko)

Manual abstract: user guide KRANZLE K1050P

Detailed instructions for use are in the User's Guide.

[. . . ] 2 Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description of high pressure cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Explanatory symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 General rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] A brief connection however is permissible according to DVGW (German Association for Gas and Water Affairs) if a non-return valve with tube ventilator (Kränzle order no. Once the water has passed through the non-return valve it is no longer considered as drinking water. Also indirect connection to the public drinking water supply lines is permissible by way of free emission in accordance with EN 61 770; e. g. Direct connection to a non-drinking water supply line is permissible. 11 Functional details Insufficient quantity of electricity Kränzle 1050 P: 230 Volt / 50 Hz If there are too many collectors in your proximity connected to the network at the same time, the available voltage and the current intensity may decline. Consequently the motor of the high pressure cleaner does not start or even blows. The power supply may also be insufficient if the power cable is too long or too thin. If extension cables are too long, this may lead to a voltage drop causing malfunctions or start-up difficulties. Check the line fusing and have the voltage and the available current intensity checked by an expert in case of uncertainty. Electrical connection The machine is supplied with a 5 meter electrical power cable with plug. The mains plug must be fitted to a standard grounded socket with a 30 mA residual current operated device. When using an extension cable, this must have an earthed lead which is properly connected to the socket. The conductors in the extension cable must have a minimum cross section of 1. 5 mm². Plug connections must be of a spray-proof design, and may not be located on a wet floor. When using a cable drum, always keep the cable wound as far as possible. 12 Functional details Water and cleaning / care products system Water can be connected at mains pressure to the high pressure pump. The water is then forced under pressure by the high pressure pump to the lance. The high pressure jet is formed by the nozzle at the end of the lance. Environmental, refuse disposal and water protection regulations must be observed! Lance with trigger gun with safety catch The machine can only be operated when the trigger of the trigger gun with safety catch is pulled. The spray pressure increases and quickly reaches the selected operating pressure. When the trigger is released, the trigger gun closes and any further spraying of liquid from the lance is stopped. The pressure thrust serves to close the start/stop system, thus causing interruption of the energy supply to the motor. Owing to this innovative system the high pressure hose is relieved and enables higher durability of the hose. Opening the gun causes the start/stop system to open, the electric motor is automatically restarted and the pump starts to transfer the water on to the high pressure jet where the cleaning jet is generated. The trigger gun with safety catch is a safety device. Should replacement parts be required, use only components authorized by the manufacturer. Replacements, repairs, new adjustments and sealing should only be performed by qualified persons. [. . . ] The high pressure cleaner is designed for private purposes only; no warranty shall be provided in case of industrial use. In case of any modifications on the safety installations or in case of exceeding the temperature and speed limit, any warranty claims shall become invalid - this shall also apply to undervoltage, lack of water and use of wastewater as well as any other faulty or inappropriate operation of the machine. Pressure gauge, nozzle, valves, sleeves, high pressure hose and spray equipment are wear parts and are not covered by the Warranty obligation. 26 Notes 27 Spare parts list complete assembly 40 41 30 42 10 1 14 13 11 3 4 6 28 K 1050 P Pos. 1 3 4 6 10 11 13 14 30 40 41 42 Bezeichnung Seitenschale Abdeckung Gummi-Metall-Anschlagpuffer 25 x 30 Ø5, 2 Kunststoffschraube 5x14 Kunststoffschraube 5x30 Kunststoffschraube 5x20 Kabelklemme Schraube 3, 5 x 14 Schlauch NW 6 8 m Pistole M2000 mit Stecksystem DN10 Lanze mit Flachstrahldüse Lanze mit Schmutzkillerdüse (optional) Stück 1 1 4 4 5 4 1 2 1 1 1 1 Art. -Nr. 49. 170 49. 171 49. 010 43. 426 43. 418 50. 157 43. 431 44. 525 41. 054 1 12. 475 12. 900-03 42. 403-03 29 Spare parts list motor 14 27 41 25 19 26 18 22 15 15 21 12 13 30 29 28 11 24 6 7 9 10 8 4 5 17 1 30 K 1050 P Pos. 1 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 19. 1 19. 2 19. 3 21 22 24 25 26 27 28 29 30 41 Bezeichnung Motor 230V / 50 Hz komplett ohne Elektrik Haube Luftführung Motor-Lager B-Seite 6203 Motor-Lager A-Seite 7304 Öldichtung 25 x 35 x 7 Lüfterrad Wellensicherungsring 17 x 1 Lagerbolzen Stator Gummidichtung Lüfterklemme 3-pol. Schaltkasten Unterteil Ein-Aus-Schalter Durchführungstülle Druckschalter- und Netzkabel Gummilager Stator Kondensator 35µF Netzanschlusskabel für 3 x 1, 0 mm² (EU) Netzanschlusskabel für 3 x 1, 0 mm² (GB) Netzanschlusskabel für 3 x 1, 0 mm² (CH) Netzanschlusskabel für 3 x 1, 0 mm² (SA) Schraube 3, 5 x 20 Innensechskantschraube M6 x 16 Erdungsschraube kpl. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KRANZLE K1050P




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KRANZLE K1050P will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.