User manual LA CROSSE TECHNOLOGY WS7018

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS7018. We hope that this LA CROSSE TECHNOLOGY WS7018 user guide will be useful to you.


LA CROSSE TECHNOLOGY WS7018 : Download the complete user guide (459 Ko)

You may also download the following manuals related to this product:

   LA CROSSE TECHNOLOGY WS7018 (476 ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY WS7018

Detailed instructions for use are in the User's Guide.

[. . . ] WIRELESS 868 MHz WEATHER STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this Weather Station with wireless 868MHz transmission of outdoor temperature and humidity and display of indoor temperature and humidity. It is further featuring a DCF-77 radio controlled clock with date display and two alarms. With eight easy to use function keys, this innovative product is ideal for use in the home or office. « Instant Transmission+» is the up and coming state-of-the-art new wireless transmission technology, exclusively designed and developed by LA CROSSE TECHNOLOGY. "IT +" offers you an immediate update of all your outdoor data measured from the transmitters: follow your climatic variations in real-time! 32 FEATURES: The Weather Station Hanging Hole LCD Display Battery cover Function Keys Detachable stand · · · · · · · · · · DCF-77 Radio controlled time with manual setting options Time reception ON/OFF 12/24 hour display Hour and minute display, seconds indicated by flashing dot Time zone option ±12hours Features 2 alarms with snooze function Snooze setting Date and month / weekday and date calendar display selectable Weather forecasting with 3 weather icons and weather tendency indicator Weather forecasting icon sensitivity setting 33 · · · · · · · · · · · · Temperature display in degrees Celsius (° or Fahr enheit (° selectable C) F) Indoor and outdoor temperature display with MIN/MAX recording Indoor and outdoor humidity reading displayed as RH% with MIN/MAX recordings All MIN/MAX temperature recordings show date and time received All MIN/MAX recordings can be reset Indoor comfort level indicator - happy or sad face icons Can take up to three outdoor transmitters LCD contrast setting Low battery indicator Wireless transmission at 868 MHz Signal reception intervals at 4 seconds Wall mounting or table standing · · · · The Thermo-Hygro Outdoor Transmitter Remote transmission of outdoor temperature and humidity to Weather Station by 868 MHz Display alternately the outdoor temperature and humidity readings on LCD Shower proof casing Wall mounting case (Mounting at a sheltered place. [. . . ] Confirm with the SET key and enter the "Calendar Setting" or exit the setting mode by pressing the CH or SNZ key Note: The unit will still try and receive the signal despite it being manually set. When it does receive the signal, it will change the manually set time into the received time. If reception has been unsuccessful, then the DCF tower icon will not appear but reception will still be attempted the following day. CALENDAR SETTING Year (flashing) Date (flashing) Month (flashing) The date default of the Weather station is 1. Once the radio-controlled time signals are received, the date is automatically updated. However, if the signals are not received, the date can also be set manually. Press the SET key to enter the month and date setting mode. 47 3. 4. Press the IN (or OUT) key to set the date and the OUT (or IN) key to set the month required. Confirm with the SET key and enter the "Snooze setting " or exit the setting mode by pressing the CH or SNZ key. SNOOZE SETTING: Snooze time The snooze time can be set OFF to a maximum time of 30 minutes (default is 10 minutes): 1. The snooze can also be set OFF when the "OFF" digit is being displayed. Confirm with the SET key and enter the "ºC / ºF temperature display setting" or exit the manual setting mode by pressing the CH or SNZ key. Note: If the snooze time has been set "OFF", the snooze function will not be activated. ° F TEMPERATURE DISPLAY SETTING C/° Flashing The default temperature reading is set to ° (degre e Celsius). The "° will be flashing, use the IN key to tog gle between "° and "° C" C" F". Once the desired temperature unit has been chosen, confirm with the SET key and enter the "Weather Forecast Icon Sensitivity setting" or exit the setting mode by pressing the CH or SNZ key. 48 WEATHER FORECASTING ICON SENSITIVITY SETTING For locations with rapid changes of weather conditions, the threshold can be set to a different level for faster display of weather conditions. There are 3 levels of setting: 1, 2 and 3; level 1 is the most sensitive setting, level 3 is the least sensitive setting (default setting is "2"). Confirm with the SET key and exit the Manual settings. ALARM SETTING: Alarm time Alarm time icon 1. 6. Press and hold down the AL1 key for about 3 seconds until the alarm time display flashes. Pressing these keys continuously moves the hours consecutively by 1 and the minutes consecutively by 5. Either press the AL1 key once more to confirm and return to the normal display or do not touch any buttons for around 15 seconds to confirm the set time. To activate the alarm function, press the AL1 button once for Alarm 1. You should now see the ((1)) alarm symbol to represent the Alarm 1 being ON. The steps for setting, activating and de-activating Alarm 2 are the same, but using the AL2 button instead of AL1. 49 SNOOZE SETTING AND STOPPING THE ALARM: 1. When the alarm is sounding, press the SNZ to activate the snooze function. [. . . ] Before wall mounting, please check that the outdoor temperature and humidity values can be received from the desired locations. Fix a screw (not supplied) into the desired wall, leaving the head extended out the by about 5mm. Remove the stand from the Weather Station by pulling it way from the base and hang it onto the screw. Remember to ensure that it locks into place before releasing. 55 POSITIONING THE THERMO-HYGRO OUTDOOR TRANSMITTER The Transmitter is supplied with a holder that may be attached to a wall with the two screws supplied. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS7018




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS7018 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.