User manual LG ASNW12GB1U0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG ASNW12GB1U0. We hope that this LG ASNW12GB1U0 user guide will be useful to you.


LG ASNW12GB1U0 : Download the complete user guide (3278 Ko)

You may also download the following manuals related to this product:

   LG ASNW12GB1U0 (5273 ko)
   LG ASNW12GB1U0 (3598 ko)
   LG ASNW12GB1U0 (3939 ko)
   LG ASNW12GB1U0 (3909 ko)
   LG ASNW12GB1U0 (5186 ko)
   LG ASNW12GB1U0 (3285 ko)
   LG ASNW12GB1U0 (3298 ko)
   LG ASNW12GB1U0 (3628 ko)
   LG ASNW12GB1U0 (4335 ko)

Manual abstract: user guide LG ASNW12GB1U0

Detailed instructions for use are in the User's Guide.

[. . . ] ENGLISH http://www. lgservice. com ITALIANO LG LG Air Conditioner OWNER'S MANUAL Type : Wall Mounted ESPAOL FRANAIS DEUTSCH PORTUGUS NEDERLANDS POLSKI IMPORTANT Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. Please retain this owner's manual for future reference after reading it thoroughly. MAGYAR Air Conditioner Owner's Manual TABLE OF CONTENTS A. Electrical Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Temporary Use of an Adapter . . . . . . . . . . . . . . . 6 Temporary Use of an Extension Cord . . . 6 Symbols used in this Manual. . . . . . . . . . . . . . . . . 6 C. Product Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Indoor Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Operation Indication Lamps . . . . . . . . . . . . . . . . . . 7 Outdoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. [. . . ] PLASMA BUTTON(Optional) Used to start or stop the plasma-purification. LED LUMINOSITY BUTTON(Optional) Used to adjust LED luminosity. Owner's Manual 9 Operating Instructions The controls will look like the following. Signal transmitter Premium type : - Optional1 ECO EYE BUTTON Used to set and to cancel the timer operation. - Optional2 JET COOL / MOISTURE COOLING BUTTON Used to start or stop the speed cooling and Moisture Cooling. - Optional3 (Optional1) SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation. (Optional2) (Optional3) Rational type : - Optional1 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation. - Optional2 Operation Mode Cooling Operation Auto Operation or Auto Changeover JET COOL BUTTON Used to start or stop the speed cooling. The Jet Cool operates fan in super high speed in cooling mode. Healthy Dehumidification Operation Heating Operation (Only heat pump) Air Circulation 10 Air Conditioner Operating Instructions Operation Mode 1 Press the ON/OFF BUTTON to turn the unit on. The unit will respond with a beep. ON/OFF ENGLISH 2 Open the cover of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. MODE Cooling Auto Healthy Heating Changeover Dehumidification (Heat pump model only) Air Circulation Auto Operation (Optional) Auto Changeover (Optional) 3 For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS. For cooling the temperature can be set within 18C~30C and for heating the temperature range is 16C~30C. TEMP 4 Set the fan speed with the remote controller. You can select the fan speed in six steps : low, medium-low, medium, medium-high, high and natural wind by pressing the INDOOR FAN SPEED SELECTION BUTTON. Each time the button is pressed, the fan speed mode is shifted in the direction of the arrow. FAN SPEED Step1(Low) Natural Wind Step2(Medium-low) Step3(Medium) Step4(Medium-high) Step5(High) Natural wind For fresher feeling, press the INDOOR FAN SPEED SELECTION BUTTON and set to Natural wind mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed. Owner's Manual 11 Operating Instructions Auto Changeover Operation (Optional) This operation is basically heating or cooling function of the air conditioner. But during this operation the controller changes the operation mode automatically to keep the temperature within 2C with respect to the setting temperature. MODE Auto Operation(Optional) <For Cooling Model> The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you feel hot or cold, press TEMPERATURE SETTING buttons for more cooling or heating effect. Please select the code as per your requirement. Code Feel 2 Cold 1 Slightly cool 0 Neutral -1 Slightly warm -2 Warm TEMP <For Heating Model> You can set desired temperature and indoor fan speed. Range : 18~30C. NOTE : You can not set the actual setting temperature and the fan speed in this operation mode , But you can use the Auto swing in this operation. If the system is not operating as desired, switch manually to another mode Healthy Dehumidification Operation During Healthy Dehumidification Operation If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON, the product starts to run the dehumidification function. It automatically sets the room temperature and airflow volume to the best condition for dehumidification, based on the sensed current room temperature. In this case, however, the setting temperature is not displayed on the remote controller and you are not able to control the room temperature either. During the healthy dehumidification function, the fan speed is automatically set according to the optimization algorithm responding to the current room temperature status, so that the room condition is kept healthy and comfortable even in the very humid season. MODE 12 Air Conditioner Operating Instructions Air Circulation Operation This operation circulates the air without cooling or heating. Once the air circulation is activated you can select the fan speed by pressing the INDOOR FAN SPEED SELECTION BUTTON. MODE ENGLISH NOTE Auto Clean Operation : During this opertion , 'Cooling' lamp lights up. During Auto Clean Operation, moistures left in indoor units after cooling operation or healthy dehumidification operation can be removed. Now whenever the unit is turned off, the indoor fan is still running for about 30 minutes internally without cooling or dehumidification operation. [. . . ] Premium type Rational type ON/OFF button ON/OFF button 20 Air Conditioner Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. ENGLISH Indoor Unit Clean the unit with a soft dry cloth. They may damage the surface of the air conditioner. Air Filters The air filters behind the front panel / grill should be checked and cleaned once in every 2 weeks or more often if necessary. To remove the filters see the self explanatory diagrams for each model type. If dirt is not easily removed, wash with a solution of detergent in luke warm water. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG ASNW12GB1U0




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG ASNW12GB1U0 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.