User manual LG STARVERT IG5 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG STARVERT IG5. We hope that this LG STARVERT IG5 user guide will be useful to you.


LG STARVERT IG5 BROCHURE: Download the complete user guide (536 Ko)

Manual abstract: user guide LG STARVERT IG5BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] The iG5 has the small inverter features and standard medium drive features together. The "DriveviewTM" software offers Window® based computer monitoring tool through RS485 interface with graphic capture, keypad emulator, parameter edit and text monitor. [. . . ] output frequency Operation Operation function Drive trip Protective function Display Keypad Inverter alarm Momentary power loss Operation information Trip information Ambient temperature Storage temperature Environment Ambient humidity Altitude . Vibration Application site Overvoltage, undervoltage, overcurrent, drive overheating, motor over heating, input/output phase loss, input/output mis-wiring, overload protection, communication error, loss of speed command, hardware fault. Stall prevention, overload alarm Less than 15 msec : continuous operation, more than 15 msec : auto restart possible Output frequency, output current, output voltage, frequency value setting, operating speed, DC voltage Indicates the fault when the protection function activates, memorizes up to 5 faults -10 °C ~ 40 °C -20 °C ~ 65 °C 90 % RH max. (Non condensing) Below 1, 000 m below 5. 9m/sec2(=0. 6g) No corrosive gas, combustible gas, oil mist, or dust 05 Specifications & Wiring Wiring DB Resistor*2 MCCB 1ø 230V or 3ø 230/460V 50/60Hz R S T G 24 Forward Run/Stop Reverse Run/Stop Drive gate block Fault Reset Jog Multi-function Input 1 Multi-function Input 2 Multi-function Input 3 Common Terminal B1 B2 U V W MOTOR + FM FM Output Frequency Meter (0 ~ 12V : pulse output) FX RX BX RST JOG P1 P2 P3 CM Factory Setting `Speed-L` `Speed-M` `Speed-H` A C B CM Fault output relay Iess than AC250V, 1A Iess than DC30V, 1A Potentiometer (1kohm, 1/2W) Shield MO Power supply for VR speed signal: +12V, 100mA V1 Speed signal input: 0 ~10V I Speed signal input: 4 ~ 20mA(250ohm) CM Common for VR, V1, I S+ SModBus-RTU RS-485 Communication port MG Multi-function output Iess than DC24V, 50mA Factory setting:`RUN` Speed signal Input*1 Note) " " display main circuit terminals, " " display control circuit terminals. DB resistor is optional. 06 Starvert iG5 Power terminal configuration Symbol R S T U V W B1 B2 G Function AC Line input (1 phase 200~230 Vac for "-1" units 3 phase, 200~230 Vac for "-2" units and 380~460 Vac for "-4" units) 3 phase output terminals to motor External additional dynamic braking resistor connection terminals. Chassis ground (The gound terminal("G") may be located on heat sink instead of terminal strip depend on the model name) Control terminal configuration Type Symbol P1, P2, P3 FX RX JOG BX Name Multi function input 1, 2, 3 Forward run command Reverse run command Jog frequency reference Drive gate block Descripton Used for multi function input. Starting Contact When the BX signal is ON, the output of the drive is cut off. When the motor uses an mechanical brake to stop, Function Slection BX is used to cut off the output signal. When the BX signal, which does not cut off by latching, is OFF and the FX signal (or the RX signal) is ON, the motor keeps running, so be cautious. RST Used to release the protective status when the protective circuit is active. Fault reset CM Used for the common terminal for contact input terminals. Frequency setting power(+12V) Analog Frequency V1 Used for frequency reference and uses 0-10V for input. Input resistance is 20 k Frequency reference (Voltage) Setting I Used for frequency reference and uses DC 4-20mA for input. [. . . ] `Risk of Electric Shock`-more than one disconnect switch is required to de energize the equipment before servicing. 4. 5 W2 W1 4. 5 4 H2 Inverter SV004iG5-1 SV004iG5-2 SV008iG5-1 SV008iG5-2 SV015iG5-1 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 HP 0. 5 0. 5 1 1 2 2 3 5 5. 4 0. 5 1 2 3 5 5. 4 W1 100(3. 94) 100(3. 94) 130(5. 12) 100(3. 94) 150(5. 90) 130(5. 12) 150(5. 90) 150(5. 90) 150(5. 90) 130(5. 12) 130(5. 12) 130(5. 12) 150(5. 90) 150(5. 90) 150(5. 90) W2 88(3. 46) 88(3. 46) 118(4. 65) 88(3. 46) 138(5. 43) 118(4. 65) 138(5. 43) 138(5. 43) 138(5. 43) 118(4. 65) 118(4. 65) 118(4. 65) 138(5. 43) 138(5. 43) 138(5. 43) H1 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) 128(5. 04) H2 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) 117. 5(4. 63) D1 130. 9(5. 15) 130. 9(5. 15) 150. 9(5. 94) 130. 9(5. 15) 155(6. 10) 150. 9(5. 94) 155(6. 10) 155(6. 10) 155(6. 10) 150. 9(5. 94) 150. 9(5. 94) 150. 9(5. 94) 155(6. 10) 155(6. 10) 155(6. 10) D1 12 Starvert iG5 Dynamic Braking(DB) Resistors 1. Standard application Drive SV004iG5-1 SV008iG5-1 SV015iG5-1 SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 Resistor capacity [W] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Resistor value[ ] 400 200 100 400 200 100 60 40 40 1800 900 450 300 200 200 Average braking torque[%] 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Enable duty[%] 5 5 3 5 5 3 2 2 2 5 5 3 2 2 2 Continuous braking time[sec] 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG STARVERT IG5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG STARVERT IG5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.