User manual LG TDC70140E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG TDC70140E. We hope that this LG TDC70140E user guide will be useful to you.


LG TDC70140E : Download the complete user guide (2963 Ko)

Manual abstract: user guide LG TDC70140E

Detailed instructions for use are in the User's Guide.

[. . . ] PART IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4. PROGRAM CYCLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 5. INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6. MAINTENANCE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7. [. . . ] Water is directly pumped out of the dryer. Installed Stacking kitside view 600 850 Installed Stacking kit rear view 595 11 6 MAINTENANCE INSTRUCTIONS Front Ventilation Grille Vacuum the front ventilation grill 3~4 time a year to make sure there must be no build-up of lints or dirts which cause improper intake air flow. Moisture Sensor? This device functions to sense the moisture remaining contents of the laundry during operation which means it must be cleaned all the time. The main reason of cleaning this part is to remove the build-up of lime scale on the surface of sensor. Wipe the sensors inside drum (Shown in the picture). Condensed water Drain-out Normally, condensed water is pumped up to water container where water is collected until emptied. Not only using water container, but water can be drained out directly to drain hose especially when dryer is stacked on top of washing machine. With connecting kit for drain hose, you can simply change water path and water reroute to the drainage facility. Thermistor (Low temp. ) Measure resistance of Terminal to terminal Resistance value : 10K Ω±5% (at 25°C) Cover, Front 3. Heater, Thermistor Measure resistance of Terminal to terminal Resistance value : Yellow/White : 28. 96 ±1 Ω Blue/White : 56. 29 ±2 Ω Resistance value : 200K Ω±5% (at 25°C) Resistance value : White/Blue : 24. 8 ±2. 5 Ω Blue/Red : 21. 5 ±2. 0 Ω Heater Thermistor Measure resistance of Therminal to terminal Measure resistance of Terminal to terminal 4. Capacitor Measure capacitance of Terminal to terminal Capacitance value : 10 ±0. 2 µF 6. Pump Measure resistance of Terminal to terminal Resistance value : 205 ±10 Ω 15 7 COMPONENT TESTING TIPS Test procedure Measure resistance of the Following terminal 1) Door switch knob :open Terminal : “COM ”-“NC ” (1-3) Terminal : “COM ”-“NO ” (1-2) 2) Door switch push :Push Terminal : “COM ”-“NC ” (1-3) Terminal :“COM ”-“NO ” (1-2) Measure resistance of terminal to terminal Component 7. Door S/W Check result Remark The state that knob is Pressed is opposite to open condition Resistance value <1 Ω Resistance value ÷ Resistance value ÷ Resistance value <1 Ω COM NO NC 8. Lamp holder Resistance value : 80 Ω~100 Ω AC 230V, 15W 16 8 CONTROL LAY-OUT PWB ASSEMBLY DISPLAY LAY-OUT PWB ASSEMBLY LAY-OUT 17 9 WIRING DIAGRAM With ELB model ELECTRIC DRYER WIRING DIAGRAM BROWN BROWN BLACK BLACK BROWN ELB ELECTRONIC CONTROL 4 2 3 1 BLACK WHITE L1 BLUE N 1 2 3 TRANS 1 3 TR1 TR2 RLY2 RLY3 NA4 RLY4 YELLOW BLACK BLUE RED RD4 RED WHT3 WHT1 EARTH SKY BLUE BL3 2 1 ORANGE CW 4 2 INLET THERMISTOR BLUE 3 1 BROWN BROWN YL3 3 2 WHITE 1 1 2 BROWN OUTLET THERMISTOR 3 4 BROWN WHITE WHITE RLY1 BLUE CCW BLACK 1 2 WIRE COIL COM WHITE WHITH NO CLOSE GRAY LAMP 1 2 3 PINK 1 2 3 NC OPEN 1 2 3 2 1 1 2 3 BROWN SKY-BLUE 4 2 1 CAPACITOR DOOR SWITCH THERMAL PROTECT THERMAL FUSE WHITE WHITE OUTER COIL 2 1 INNER COIL MOTOR HEATER TH2 THERMOSTAT PUMP PUMP SENSOR MOTOR TH1 ELECTRODE SENSOR P/No. :3854EL4007B 18 10 TROUBLESHOOTING 1. Activating the Heater manually with Door open may trp the Thermostat attached to the Heater, therefore do not activate it manually, (Do not press the door switch to operate the heater while the door is open) Activating the diagnostic test mode 1. Press “POWER”while pressing “Iron-dry Buzzer”and “Anti-crease” simultaneously . Pressing the “START/PAUSE”button CHECKING ACTION DISPLAY CHECKING POINTS Check all LEDs for operation. None Electric control REMARK Once Motor Motor run counterclockwise. 70~245 Displays Moisture Sensor Operation:If Measured moisture sensor is contacted with damp Moisture Value cloth. 70~245 Displays Moisture Sensor Operation:If Measured moisture sensor is contacted with damp Moisture Value cloth. Current temperature Heater run(Display the temperature of low temperature themirstor located under door. ) Motor run clockwise. Heater run(Display the temperature of high temperature thermistor located in heater assembly. ) Pump run Twice Motor 3 times Motor + Heater 1 4 times Motor+Heater 1 +Heater 2 Motor off + Pump on Current temperature Water level in sump 5 times 6 times Motor 7 times 8 times Motor & Heater off Buzzer On Control Off Motor runs 70~237 Displays Moisture Sensor Operation:If Measured moisture sensor is contacted with damp Moisture Value cloth. The display number is below 180, in normal condition. ELB Sensor If ELB Sensor is in normal condition, ELE “ELE” is displayed. - Press the “Quick” and “Anti-Crease” button as follows. No. of Button pressing 1 time 2 times 3 times 4 times Display Moisture data Temperature sensed by low temperature thermistor (located under door) Temperature sensed by High temperature thermistor (located in heater assembly) Remaining water data by water level sensor 19 10 TROUBLESHOOTING : LED displays “ ” in case of the door open. The door must be closed and start Button must be pressed for re-operation. Power-On - Repair or replace the Controller. Power button press Error Mode LED-SEG ON NO YES Check Red 4P Housing Check Test Mode Check Thermistor resistence Replace PCB Power button Lock:No buzzer Circuit breaker trip Low temperature Door Open? [. . . ] Disassemble Nut by grasping the edge of left motor shaft at the same time. 33 12 DISASSEMBLY INSTRUCTIONS 1. Disassemble Capacitor by unscrewing Nut. CAPACITOR HOUSING 3. Disassemble Heater Housing by detaching inner Connector harness and unscrewing. 4. Disassemble Heater by unscrewing 2 screws. HEATER 34 12 DISASSEMBLY INSTRUCTIONS 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG TDC70140E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG TDC70140E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.