User manual LIEBHERR WKES 653 GRAND CRU

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIEBHERR WKES 653 GRAND CRU. We hope that this LIEBHERR WKES 653 GRAND CRU user guide will be useful to you.


LIEBHERR WKES 653 GRAND CRU : Download the complete user guide (867 Ko)

You may also download the following manuals related to this product:

   LIEBHERR WKES 653 GRAND CRU (873 ko)
   LIEBHERR WKES 653 GRAND CRU (875 ko)
   LIEBHERR WKES 653 GRAND CRU (873 ko)
   LIEBHERR WKES 653 GRAND CRU (870 ko)
   LIEBHERR WKES 653 GRAND CRU (870 ko)
   LIEBHERR WKES 653 GRAND CRU (871 ko)

Manual abstract: user guide LIEBHERR WKES 653 GRAND CRU

Detailed instructions for use are in the User's Guide.

[. . . ] 20 Audible warning signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Interior light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Storage diagrams for 750 ml Bordeaux bottles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 29 Description of appliance and equipment Operating and control elements Interior light Bottle grid Activated carbon filter Type plate Adjustable- height feet 17 Setting up · Avoid locating it in direct sunlight or near heat sources such as an oven or a radiator. You can compensate for an uneven floor by adjusting the adjustable feet. · Standard EN 378 specifies that the room in which you install your appliance must have a volume of 1 m3 per 8 g of R 600a refrigerant used in the appliance, so as to avoid the formation of inflammable gas/air mixtures in the room where the appliance is located in the event of a leak in the refrigerant circuit. The quantity of refrigerant used in your appliance is indicated on the type plate on the inside of the appliance. · The appliance is set to operate within specific ambient temperature limits according to its climate rating. The correct climate rating for your appliance is indicated on the type plate. SN - ST = +10°C to +38°C SN - T = +8°C to +43°C Dimensions WK 2977: height: 1264 mm, width: 660 mm, depth: 671 mm WK 4177: height: 1658 mm, width: 660 mm, depth: 671 mm WK 4677: height: 1855 mm, width: 660 mm, depth: 671 mm Electrical requirement Power supply (AC) and voltage at the operating point must comply with the details on the type plate. The type plate is located on the top left-hand side on the inside of the appliance. The socket must be fused with a 10 A fuse or higher, it must be away from the rear of the appliance and must be easily accessible. Operating and control elements Temperature display Temperature setting buttons Audible warning on/off button Interior light on/off button Child-proof lock On/off button Fan switch 18 Switching the appliance on and off GB You are recommended to clean the appliance before switching it on for the first time (see "Cleaning"). · To switch the appliance off: Keep the "ON / OFF" button pressed for 3 sec. · To switch the appliance on: Press the "ON / OFF" button until the Display lights up. Setting the temperature To reduce the temperature: Press the DOWN button; To increase the temperature: Press the UP button. An activated carbon filter has been fitted in the lower area of the rear wall of the appliance to ensure that the air throughput remains at an optimum quality. Turn it 90° to the left or right until it clicks into place. 22 Storage diagrams for 750 ml Bordeaux bottles GB The loading pattern illustrated is only an example: the appliance can be loaded with different quantities depending on how the shelves are arranged. WK 4677 187 bottles WK 4177 162 bottles WK 2977 108 bottles 210 mm 210 mm 210 mm 150 mm 210 mm 210 mm 230 mm 270 mm 270 mm 230 mm 210 mm 210 mm 270 mm 270 mm 230 mm 23 Defrosting The appliance defrosts automatically. The water that forms on the rear wall drains into a reservoir at the back of the appliance and evaporates automatically through the compressor heat. Cleaning Before cleaning always switch off the appliance. · Do not use abrasive sponges or scourers, do not use concentrated cleaning agents and never use cleaning agents containing sand, chloride or acid or chemical solvents, as these would damage the surfaces and could cause corrosion. · Use a glass cleaner to clean the glass surfaces and a commercially available stainlesssteel cleaning agent for the stainless-steel surfaces. · Clean the inside and equipment with lukewarm water and a little detergent, with the exception of the wooden trims on the grid shelves. · Ensure that no cleaning water penetrates into the electrical components. · Do not remove the type plate from the inside of the appliance; it is important for after-sales servicing. 24 Malfunctions GB Your appliance is designed and manufactured for a lengthy, reliable operating life with no malfunctions. If a malfunction nonetheless occurs during operation, check whether it is due to an operating error. Please note that even during the warranty period the resultant servicing costs in this case will have to be borne by the owner. [. . . ] The type plate is located on the left-hand inside wall. Shutting your appliance down If your appliance is to be shut down for any length of time, switch it off and disconnect the plug or remove the fuse. Clean the appliance and leave the door open in order to prevent unpleasant smells. 25 Changing over door hinges 1 2 3 Remove screw from lower hinge bracket. Lift door 1, tilt to the right 2 and remove 3. Transfer pin to the opposite side of the door. 4 5 6 Transfer upper hinge components to the opposite side. Transfer lower hinge bracket to the opposite side. Transfer handle to the opposite side. 7 8 9 Locate door on upper pin. Tilt door inwards from the left 1. In the event of damage, make sure that there are no ignition sources nearby and keep the room well ventilated. General information The refrigerant circuit has been tested for leaks. The appliance is radio-suppressed to EN 55014 and thus complies with EC Directive 87/308/EEC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIEBHERR WKES 653 GRAND CRU




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIEBHERR WKES 653 GRAND CRU will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.