User manual LIFT-MASTER CPS-04-01

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER CPS-04-01. We hope that this LIFT-MASTER CPS-04-01 user guide will be useful to you.


LIFT-MASTER CPS-04-01 : Download the complete user guide (800 Ko)

Manual abstract: user guide LIFT-MASTER CPS-04-01

Detailed instructions for use are in the User's Guide.

[. . . ] CPS-LN4: Direct connect photo eyes suitable with Logic 2 and Logic 3 operators. CPS-N4: Suitable for use with Logic 2 and Logic 3 operators when more than (1) set of photo eyes are required. Example: Fire station, use (1) set of direct connect CPS-LN4 and CPS-N4. Install the Protector System ® IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR Be sure power to the operator is disconnected. [. . . ] Floor or Wall Mount Installation (Figure 1) If necessary, see Figure 2 for various assembly options to fit your application. NOTE: Putting track bolts in slots will prevent brackets from pivoting. Track Installation (Figure 3) To mount to door track use only one bracket per side. To vertically attach to 2" x 4" wall stud it may become necessary to rotate bracket to prevent wood from splitting. Figure 1 Hex Mounting Nut for Sensor Lock Washer for Sensor Floor or Wall Mounting 1/4"-20 x 5/8" Track Bolts 1/4"-20 x 5/8" Track Bolts 1/4" Flat Washer 1/4" Lock Washer 1/4"-20 Hex Nut 1/4" x 1-1/2" Lag Screws Door Track Mounting Figure 3 1/4" Flat Washer 1/4" Lock Washer 1/4"-20 Hex Nut Figure 2 Assemble to either side Flip one bracket and assemble to either side 1/4" Lock Washer 1/4"-20 Hex Nut Door 1/4" Drill Holes 1/2" Hole Spacing 2" Hole Spacing 1/4"-20 x 5/8" Track Bolts Assembly Variations CONDUIT CONNECTIONS Use a liquid tight fitting (1/2" trade size) with sealing washer to connect to sensors. We recommend the use of a liquid tight junction box near each sensor to make the connection to the sensor leads (Figure 4). Use rigid or flexible liquid tight conduit (depending on local codes) from junction boxes to operator. WIRING CONNECTIONS: CPS-N4 - See page 3 CPS3-N4 - See page 4 CPS-LN4 - See page 5 Figure 4 Liquid Tight Conduit Liquid Tight Junction Box See Wiring Connections Sensor Beam 6" (15 cm) max. above floor Liquid Tight Junction Box Invisible Light Beam Protection Area Sensor Beam 6" (15 cm) max. above floor 2 W I R I N G F O R L I F T M A S T E R C O M M E R C I A L O P E R AT O R S CPS3-N4 Wiring Connections for use with Logic Operators (L2 or L3) Insert Logic Board into any available slot CPS3 Option Logic Board Logic 3 Board Shown Commercial Door Opener Protector System® Only 270K Resistor A B C D E F G H I J Brown Blue Commercial Door Opener Protector System® and 2-Wire Fail Safe Door Edge 2-Wire Edge JU1 R16 A B C D E F G H I J Brown Blue CPS3 protector and 2-wire fail-safe door edge connections For a 2-wire safety edge with an embedded resistor; 1. Add the resistor to 2 of the 4 wires at the safety edge, connect the coil cord to the other 2 safety edge wires (Figure 1). NOTE: If the LiftMaster® photo eyes are not being connected you must remove the JU1 and R16 resistors from the CPS3CARD. Figure 1 Terminal A Terminal B 2-Wire s. e. Adding the Resistor 270K Resistor 3 Commercial Door Opener Protector System® and 4-Wire Fail Safe Door Edge 270K Resistor Brown Blue JU1 R16 A B C D E F G H I J Door Edge Contacts 4-Wire Edge NOTE: When using a 4-wire door edge only (without the LiftMaster® photo eyes), you must remove the JU1 and R16 resistors from the CPS3 card. The maximum door edge resistance should be less than 1000 ohms as measured between any 4 conductors. This measurement should be taken when the door edge is in the closed contact state. Connection at CPS CPS-N4 Interface Box Operator/Auxiliary Point Connections Emitter Wire Receiver Wire Mechanical Terminal Logic 2 Terminal Logic 3 Terminal at CPS CPS-N4 at CPS CPS-N4 at Operator at Operator at Operator 3* 12 13 Wire Nut* 13 14 24V Common Sensor Black Sensor White Sensing Edge Sensing Edge or Brown or Blue Input (1/2) Input (2/2) Emitter Black Emitter White or Brown or Blue Receiver Black Receiver or Brown White or Blue 3* 8 8 10* 11 11 7 5 5 Diagram Reference Page OmniControl Surge HCT Terminal Suppressor Terminals OmniBoard Terminals Elite Gate OmniControl Application 1 Surge Suppressor Terminals Elite Gate Application 2 OmniControl Surge Suppressor Terminals 13 11 3 4 7 Sensor (1/2) Sensor (1/2) 7 13 11 13 11 3 TB3 1/3 See page 5 for inside vs outside photoeye 4 TB3 2/3 See page 5 for inside vs outside photoeye GL Board Terminal 9 or 10 See page 6 for inside vs outside photoeye 7 Estate Series with X3 or B3 Control Board at Operator TB7 1/2 Available TB7 2/2 Available 5 Operators with GL Control Board at Operator External Radio Terminal Strip R1 External Radio Terminal Strip R2 GL Board Terminal 5 6 *NOTES: Typical connections shown. [. . . ] The operator will not close if the indicator light in either sensor is not glowing steadily, alerting you to the fact that the sensor is misaligned or obstructed. NOTE: For non-solid state operators, if the door is stopped in a mid position, activation of the sensors will cause the door to open. If the sending eye and receiving eye indicator lights do not glow steadily after installation, check for: · Electric power to the opener. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER CPS-04-01




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER CPS-04-01 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.