User manual NAVMAN FUEL 2100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAVMAN FUEL 2100. We hope that this NAVMAN FUEL 2100 user guide will be useful to you.


NAVMAN FUEL 2100 : Download the complete user guide (305 Ko)

You may also download the following manuals related to this product:

   NAVMAN FUEL 2100 (297 ko)
   NAVMAN FUEL 2100 (330 ko)
   NAVMAN FUEL 2100 (309 ko)
   NAVMAN FUEL 2100 (299 ko)
   NAVMAN FUEL 2100 (300 ko)
   NAVMAN FUEL 2100 (288 ko)

Manual abstract: user guide NAVMAN FUEL 2100

Detailed instructions for use are in the User's Guide.

[. . . ] 4 Changing the fuel remaining value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Setting the low fuel alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Alarm activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Resetting the TRIP LOG or the TOTAL LOG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] If no alarm value has been entered the LCD will indicate 0FF. FLOW Alarm activation If the fuel remaining value drops below the fuel alarm value, the alarm will sound and the alarm arrow will flash. ^ V TOTAL ALr 012 0FF Press and hold both keys for three seconds and the displayed value will begin to flash. The alarm arrow will continue to flash as long as the alarm condition remains. 12 # Resetting the TRIP LOG or the TOTAL LOG To reset a log, press the key until the display indicates the name of the log to be reset. Display will show trP or tOt for 2 seconds before resetting to zero. Press and hold for 3 seconds 812 Use the and keys to select the desired alarm value. Press and hold both keys for one second to save this new value to memory and to exit this function. The display will indicate ALr and then the new value. trP tOt 000 The trip log value may be reset without changing the total log value. If the total log is reset to zero, then the trip log will automatically reset to zero. Note : If the total log exceeds 999 then both it and the trip log will be reset to zero. The arrow pointing at the alarm bell will be activated. ALr 814 # NAVMAN FUEL 2100 Installation and Operation Manual 5 2 Instrument Setup Selecting units of measure The FUEL 2100 will indicate fuel values in Litres, Imperial gallons or US gallons. Power up the unit while holding down the key. FLOW Calibration The fuel transducer supplied with the fuel flow meter will provide readings at better than 5% accuracy. Individual calibration will increase this level of accuracy to better than 2% over a fuel flow range of 10. 0 to 120 litres per hour. Take note of the actual volume of fuel used and the fuel used indicated by the total log. If these two totals are different the instrument may require calibration. Press and hold the key while applying power ^ V TOTAL Hold down during power up 2. To select the display unit desired, use the and keys to change the value. To exit this mode, press and hold both the and keys simultaneously for one second. Imperial Gallons ^ US Gallons 5. Use the or keys to make the display indicate the actual volume of fuel used. Press and hold for 1 second The fuel flow meter is now calibrated. Press and hold to exit Information will now be indicated in the selected display unit. 6 NAVMAN FUEL 2100 Installation and Operation Manual 3 Installation WARNING IT IS VERY IMPORTANT TO INSTALL A FUEL FILTER BETWEEN THE FUEL FLOW TRANSDUCER AND THE FUEL TANK. THIS FILTER WILL CATCH LARGER PARTICLES OF DIRT FROM THE FUEL TANK AND PREVENT THE FINE GAUZE FILTER IN THE FUEL FLOW TRANSDUCER FROM BECOMING BLOCKED AS THIS MAY DAMAGE THE ENGINE. Location The FUEL 2100 is designed for above or below deck installation. Select a position that is: · · · · · · On a flat surface At least 300mm (12") from a compass At least 500mm (20") from any radio Easy to read by the helmsman and crew Protected from physical damage Accessible to electrical cable connections Mounting The instrument panel must be 3mm to 19mm (1/8" to 3/4") in thickness. · · · Drill a 51mm (2") hole in the instrument panel. Remove brackets and insert the instrument so the back is flush with the instrument panel. Slide the bracket over the instrument and tighten the mounting nut until secure. Instrument Panel 51mm (2") Hole Mounting Nut Mounting Bracket Instrument Sealing Gasket NAVMAN FUEL 2100 Installation and Operation Manual 7 Wiring Connection · Keep electrical and transducer cables away from alternator or other noise generating electrical cables. Avoid connecting the instrument to power circuits that share loads with ignition, alternators, inverters and radio transmitters. [. . . ] Diario de Noticias 1997 CEP Thong Electronics (Thailand) 90810-080, Bairro Cristal, Porto Company Ltd. Mahachai, Ph: +55 51 3242 9972 Muang, Samutsakhon 74000, e-mail: equinautic@equinautic. com. br Thailand. Ph: +66 34 411 919 MIDDLE EAST Lebanon and Syria Letro, Balco Stores, Moutran Street, Tripoli VIA Beirut. Ph: +961 6 624512 e-mail: balco@cyberia. net. lb United Arab Emirates Kuwait, Oman, Iran & Saudi Arabia Abdullah Moh'd Ibrahim Trading, opp Creak Rd. Ph: +971 4 229 1195 e-mail: mksq99@email. com AFRICA South Africa Pertec (Pty) Ltd Coastal, Division No. 16 Paarden Eiland Rd. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAVMAN FUEL 2100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAVMAN FUEL 2100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.