User manual NAVMAN NAVBUS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAVMAN NAVBUS. We hope that this NAVMAN NAVBUS user guide will be useful to you.


NAVMAN NAVBUS : Download the complete user guide (202 Ko)

You may also download the following manuals related to this product:

   NAVMAN NAVBUS (214 ko)
   NAVMAN NAVBUS (213 ko)
   NAVMAN NAVBUS (214 ko)
   NAVMAN NAVBUS (213 ko)
   NAVMAN NAVBUS (213 ko)
   NAVMAN NAVBUS (209 ko)
   NAVMAN NAVBUS (213 ko)
   NAVMAN NAVBUS (212 ko)

Manual abstract: user guide NAVMAN NAVBUS

Detailed instructions for use are in the User's Guide.

[. . . ] 5 4-1 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4-2 NavBus junction box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4-3 Fitting the cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4-4 Junction box power, NavBus data wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The positive line should be protected by a circuit breaker, 10 A recommended. In addition, each cluster of instruments requires a fuse in the positive power supply. NAVMAN junction boxes have the required fuses built in, otherwise fit 1 A fuses. Part numbers: Description NavBus Kit NavBus junction box (without cables) 10 m (33 ft) data cable for use with junction box 10 m (33 ft) power cable for use with junction box Rest of world Europe AA002616 43035 AA002617 40647 CB000059 43036 CB000061 43037 NavBus junction box NavBus kit 4 Installation Warnings The NavBus junction box has a drip-proof cover. The warranty does not cover damage caused by moisture or water entering the junction box. Ensure that any holes that you cut will not weaken the boat's structure. If in doubt, consult a qualified boat builder. 4-1 Position When fitting the NavBus junction box ensure that there is sufficient space under the overhang to allow for removal of cover. Important: Minimum clearance under overhang edge 67 mm (2 5/8") Always orient the NavBus junction box so the lugs are pointing down. 5 NAVMAN NavBus Installation and Operation Manual 4-2 NavBus junction box The NavBus junction box simplifies wiring systems of instruments. The box has one four-way terminal block for attaching power and data cables and four seven-way terminal blocks for attaching power/data cables from colour coded NAVMAN instruments. When fitting a NavBus junction box: Orient the box so that the cable tie lugs point down. Match the wire colours to the colours of the terminal block terminals. Note: Minimum clearance under overhang edge 67 mm (2 5/8") NavBus junction box Fuse, 1 A typical Mounting screw Jumper Schematic Fuse, 1 A typical Jumper Red Black Orange Blue Green Yellow White Note: refer to Appendix A for colour coding Lugs to hold cable ties 4-3 Fitting the cover The NavBus junction box cover slides from the top into place. NAVMAN NavBus Installation and Operation Manual 6 4-4 Junction box power and NavBus data wiring Power wiring can be simplified by wiring power to the junction box, each instrument is powered from the NavBus junction box(es). System with one junction box No external NavBus data cable is required. Junction box Red Black Orange Blue Green Yellow White Power cable Boat's instrument power switch Red 12 V DC power Black System with more than one junction box The power and NavBus data cables can be connected together in a star, daisy-chain or any combination of the two. The maximum total length of NavBus data cable in a system is 100 m (330 ft). Junction box Red Black Orange Blue Green Yellow White Junction box Red Black Orange Blue Green Yellow White Boat's instrument power switch Power cable Red 12 V DC power Black Power cable NavBus data cable Power cable NavBus data cable Cables to more junction boxes Note: the 10 m (33 ft) NAVMAN power and NavBus data cables can be cut if required. 7 NAVMAN NavBus Installation and Operation Manual 4-5 External beeper (alarm) wiring An alarm activates the external alarm on all instruments that are able to display that specific alarm. It is only necessary to connect the external beepers or lights to a green terminal in one junction box. Red External beepers or lights Here, two sets of external beepers or lights are connected. Green DEPTH 3100 DEPTH 3100 Red External beepers or lights Green DEPTH 3100 Red External beepers or lights Green DEPTH 3100 Important: Ensure wires are stripped and tinned. 4-6 Junction box instrument wiring SPEED 3100, DEPTH 3100, MULTI 3100 or WIND 3100 Wire the instrument's power/data cable to one of the seven-way terminal blocks in the junction box. Wire any REPEAT 3100s to the end terminal block (see next page), otherwise ensure the jumper is fitted in the junction box. (See section 4-2) Wire any NMEA inputs or outputs required for the instrument to the yellow or white terminals. For example, in the diagram below right, there is a DEPTH 3100 and a MULTI 3100, which both have depth transducer inputs. In some circumstances no transducer is required, refer to each instrument's Installation and Operation manual. [. . . ] Paarden Eiland, 7405 Postal Address: PO Box 527, Paarden Eiland 7420 Cape Town, South Africa. Ph: +27 21 511 5055 Fax: +27 21 511 5022 e-mail: info@kfa. co. za SOUTH AMERICA Argentina HERBY Marina S. A. Ph: +54 11 4312 4545 Fax: +54 11 4312 5258 e-mail: herbymarina@ciudad. com. ar Brazil REALMARINE Estrada do Joa 3862, CEP2611-020, Barra da Tijuca, Rio de Janeiro, Brasil. Ph: +55 21 2483 9700 Fax: +55 21 2495 6823 e-mail: vendas@marinedepot. com. br Equinautic Com Imp Exp de Equip Nauticos Ltda. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAVMAN NAVBUS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAVMAN NAVBUS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.