Manual abstract: user guide NILFISK DYNAMICS 840
Detailed instructions for use are in the User's Guide.
[. . . ] The operating instructions and the safety precautions contained therein must be observed when using appliances connected to the appliance plug socket of the cleaner. USING FOR THE FIRST TIME Before using the cleaner for the first time, check that it is in a good and safe condition. Plugs and connectors of mains leads must be at least splash water-proof. Inspect the mains lead at regular intervals for damage or signs of ageing. [. . . ] If the vacuum cleaner is not required for a longer period of time, pull the mains plug out of the electrical outlet.
2. 5
Operating vacuum cleaner 2. 5. 1 Before switching on (Fig. 4) Before switching the vacuum cleaner on, check whether the exhaust air outlet (1) is free and the cooling air inlet (2) of the motor is not covered or blocked and clear if necessary.
2. 2
Connecting suction hose
2. 5. 2 Switching vacuum cleaner on/off Operate unit switch: Switch position "I": Vacuum cleaner runs with one turbine. Switch position "II": Vacuum cleaner runs with two turbines. First run vacuum cleaner in position "I", then switch to position "II". Switch position "A": Vacuum cleaner in automatic mode.
(Fig. 3) Pull locking pin to connect or remove the suction hose.
2. 3
Electrical connection
The operating voltage indicated on the rating plate must correspond to the mains voltage. l Insert plug of power cable into a properly installed CEE outlet (clockwise phase sequence, connected load 3 x 16 A) . Make sure vacuum cleaner is switched off.
11
Use/Operation
Dynamics 840
3 Care/Maintenance
3. 1
Important safety precautions
Only carry out maintenance work described in these operating instructions and use only genuine WAP spare parts. Changes of this type could endanger your safety.
Please contact Wap Customer Service or an authorised workshop for further maintenance and repair work.
CAUTION!Always pull out the mains plug before performing cleaning or maintenance work on the vacuum cleaner. 3. 2 Maintenance schedule
Activity 3. 3 Emptying tank
As required Monthly l l l
3. 4. 1 Blowing off filter 3. 4. 2 Replacing filter element
Care/Maintenance
3. 3
Emptying tank
3. 4 Filter element 3. 4. 1 Blowing off filter (Fig. 8) With vacuum cleaner switched on: l Connect compressed-air hose to connection with quick coupling and leave connected for approx. Compressed air: Maximum 8 bar.
(1) of cover (2) by turning 90° and pull off. 6) l Switch off vacuum cleaner by setting main switch to "0" position. l Swing bar (1) of tank lock downward; tank is raised and locked.
3. 4. 2 Changing filter element (Fig. l Unlock four quick-lock screws
12
Dynamics 840
l Pull off filter element (6) upward. l Dispose of used filter element in accordance with legal regulations. 10) l Fit cover (4), making sure that notches in cover are located over supports (9) of filter carrier ring. l Guide power cable (10) through opening of cover (2) and under handle (11). If overcurrent protection or temperature monitoring unit triggers repeatedly, inform Wap Customer Service · Check contact loop(s) or contact points
Motor does not run
> Circuit breaker of connection outlet has been tripped > Circuit breaker tripped due to wrong rotating field > Overcurrent protection or temperature monitoring unit has been triggered
> Automatic mode only: - No vacuum power is required - Contact loop of automatic system not closed
Reduced suction power
> Suction nozzle blocked > Suction hose blocked > Filter cartridge dirty
· Clean suction nozzle · Clean suction hose · Clean filter cartridge (see Section 3. 4. 1) or replace (see Section 3. 4. 2) · See Section 3. 6
> Exhaust-air flap of stopped turbine jammed
4. 1
Warranty
4. 2
Company address
Our General Conditions of Sale and Delivery apply for the warranty and warranty period.
Wap Reinigungssysteme GmbH & Co Guido-Oberdorfer-Str. 2-8 89287 Bellenberg Germany
15
Wap Service
4 Wap Service
EG - Konformitätserklärung
Wap Reinigungssysteme GmbH & Co. Guido-Oberdorfer-Straße 2-8 D-89287 Bellenberg Erzeugnis: Typ: Schmutzsauger Dynamics 840 Type: Beschreibung: 400 V 3~, 4000 W Description:
Déclaration de conformité CE
Wap Reinigungssysteme GmbH & Co. [. . . ] China Tel. : (+86) 755 8359 7937 Fax: (+86) 755 8359 1063 POLAND Nilfisk-ALTO Division of Nilfisk-Advance A/S 05-800 Pruszków ul. 3-go MAJA 8 Poland Tel. : (+48) 22 738 37 50 Fax: (+48) 22 738 37 51 info@nilfisk-alto. pl www. nilfisk-alto. pl NORWAY ALTO Norge AS Bjørnerudveien 24
1266 Oslo Norway Tel. : (+47) 22 75 17 70 Fax: (+47) 22 75 17 71 E-mail: info@nilfisk-alto. no www. nilfisk-alto. no PORTUGAL Nilfisk-ALTO Division of Nilfisk-Advance Lda. Sintra Business Park Zona Industrial Da Abrunheira o Edificio 1, 1 A P-2710-089 Sintra Tel. : (+35) 808 200 537 Fax: (+35) 121 911 2679 E-mail: mkt@nilfisk-advance. es www. nilfisk-alto. com SINGAPORE Nilfisk-Advance Pte. Nilfisk-ALTO Division 40 Loyang Drive Singapore 508961 sales@nilfisk-advance. com. sg Tel. : (+65) 6 759 9100 Fax: (+65) 6 759 9133 SPAIN Nilfisk-ALTO Division of Nilfisk-Advance S. A. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE NILFISK DYNAMICS 840
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NILFISK DYNAMICS 840 will begin.