User manual OREGON SCIENTIFIC BAR338PA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC BAR338PA. We hope that this OREGON SCIENTIFIC BAR338PA user guide will be useful to you.


OREGON SCIENTIFIC BAR338PA : Download the complete user guide (195 Ko)

Manual abstract: user guide OREGON SCIENTIFIC BAR338PA

Detailed instructions for use are in the User's Guide.

[. . . ] Batteries are to be inserted with polarities in the direction shown in the diagram on page 3 for the remote sensor unit and page 4 for the main display unit. Replace the battery compartment door. To project the time-temperature onto a flat surface: In a darkened room, press [ SNOOZE / LIGHT ], the projection will activate for approximately 5 seconds. This unit has several features to enhance the clarity of the projected image. 4 Projector Features Feature Adjustable Projector Effect Rotates 180° to cast image onto any wall Instructions Adjust by pivoting forwards or backwards the projector, so that the projection lens is pointed in the appropriate direction FOCUS Knob (A11) [ ] Rotates image on a given surface to maintain an upright position Horizontally flips an image on a given surface to maintain an upright position Flips an image to maintain an upright position Focuses image Rotate knob forwards or backwards until the image clarity is optimized Turns an image to maintain an upright position IMAGE ROTATION knob (A10) 180° ROTATION button (A12) 1. [. . . ] Note that the appropriate time zone needs to be selected each time if the BAR338PA is moved from one time zone to another. Press [ZONE] button to select among the 4 US time-zones: Pacific, Mountains, Central or Eastern. 4. Press [ALARM]. ] or [ ] buttons. HOW TO MANUALLY SET THE CALENDAR CLOCK When travelling outside of the US Atomic Clock signal reception range, the BAR338PA can be manually set to operate as a quartz clock. Note that setting the clock manually will disable the signal reception and synchronization function. Follow the same procedure to set the year, month, day and display language. ] or [ ] buttons. The alarm is automatically activated after the setting procedure. To ] indicator when deactivate it, press [ALARM] to turn off the [ the alarm time is displayed. ALARM AND SNOOZE FUNCTION When the alarm is activated, it will go off at the set time. will light up for five seconds and the [ The crescendo function allows the alarm to start off gently and with its intensity in four steps. If the [SNOOZE/LIGHT] button is pressed, the SNOOZE function will be triggered. The alarm will stop for eight minutes before going off again. INDOOR AND OUTDOOR TEMPERATURES Press [IN/OUT] to toggle between indoor temperature and outdoor temperature. Press [°C/°F] to display the temperature in Centigrade °C or Fahrenheit °F. HOW TO SET THE ALARM 1. 7 ] or [ ] buttons. GB GB MAXIMUM AND MINIMUM TEMPERATURES Press [IN/OUT] to select indoor or outdoor temperature display. Then press [MEMORY] repeatedly to scroll through current maximum and minimum temperatures recorded. Then press and hold [MEMORY] for two seconds to clear the memory for the selected display. WEATHER FORECAST The unit is capable of detecting barometric pressure changes, and basing on the data collected, can provide a general weather forecast for the next 12 to 24 hours. The effective range is 30 to 50 km (18. 6 - 31 miles). INTERRUPTED SIGNALS sunny If without obvious reasons the display for the outdoor temperature becomes blank, press and hold [IN/OUT] for two seconds to enforce an immediate signal search. Make sure the transmission is within range and path is clear of obstacles and interference. The maximum transmission range between the remote sensor and the main display unit is 90 feet (28 meters). The accuracy of a general pressure-based weather forecast is about 70 to 75%, and therefore, cannot be held responsible for any inconveniences so caused by an inaccurate forecast. The "Sunny" icon, when appears at nighttime, implies clear weather. When temperature goes equal or below 3OC (+37. 4 OF), the snow icon will display instead of the rainy icon. partly cloudy cloudy rainy snow TRANSMISSION COLLISION Signals from household devices, such as doorbells, home security systems and entry controls, may interfere with those of this product and cause temporarily reception failure. This is normal and does not affect the general performance of the product. [. . . ] FCC : NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC BAR338PA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC BAR338PA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.