Detailed instructions for use are in the User's Guide.
[. . . ] Operating Instructions <Basics>
Remote Camera Controller
Model No.
AW-RP50N
Before operating this product, please read the instructions carefully and save this manual for future use.
For instructions on how to operate this Remote Camera Controller and how to establish its settings, refer to the "Operations and Settings" manual (PDF file) which can be found on the CD-ROM supplied with the camera.
3TR006515BAA
Safety precautions
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE, USE THE RECOMMENDED ACCESSORIES ONLY. FCC Note: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. [. . . ] While the lens iris is being adjusted, a level meter is displayed on the LCD panel. (What is displayed by the level meter is an approximate value. ) IRIS -- ---+------
2 3 4
Note
When performing adjustments for one remote camera from a multiple number of AW-RP50 remote camera controllers, the level meter may not show the correct displays.
Select the remote cameras.
Select the remote cameras to be controlled using the CAMERA STATUS/SELECTION buttons.
Adjust the direction in which the remote cameras are to be pointed.
Use the PAN/TILT lever to adjust the direction in which the remote cameras are to be pointed.
6
Adjust the focus.
Turn the FOCUS/PUSH OTAF dial, and adjust the lens focus. When the dial is pressed during manual focusing, the auto focus mode is established temporarily, and the subject is brought into focus automatically. The OTAF (one-touch auto focus) takes effect for remote cameras which are equipped with the OTAF function.
Adjust the zoom.
Use the ZOOM button to adjust the lens zoom. When the TELE side is pressed, the zoom is set to the telephoto mode; when the WIDE side is pressed, it is set to the wide-angle mode.
7
Turn off the unit's power.
Set the POWER switch to the OFF position. The unit's power is turned off, and the POWER indicator goes off. Even when the unit's power is turned off, the power of the connected remote cameras does not go off.
1, 7
F1 F2
POWER
ALARM
F1
CAMERA OSD
1
MENU PAGE
GAIN/PED
2
R/B GAIN
3
R/B PED
4
AWB/ABB
5
SHUTTER
F2
EXIT
6
STORE DELETE
DETAIL
7
8
9
10
SYSTEM
SETUP SCENE/MODE CAMERA PRESET MEMORY / MENU
USER1
USER2
5
IRIS AUTO
1
2
3
4
5
PT ACTIVE
CAMERA STATUS / SELECTION
4
TELE ZOOM WIDE
AUTO
3
FOCUS/PUSH OTAF
LOW HI PTZ/FOCUS SPEED
PAN/TILT
6
2
For detailed operations, refer to the Operating Instructions -- <Operations and Settings>.
16
Basic operations for the menus
1 2
Set the MENU button to ON.
Press the MENU button and light its indicator. Press the EXIT button to return the menu to its previous hierarchical level. When the down arrow "" is displayed for a setting item, it means that the value shown will be entered and the setting reflected when the F1 dial or F2 dial is pressed. 1. GROUP SELECT 1 When the down arrow "" is not displayed for a setting item, it means that the value shown will be entered and the setting reflected when the F1 dial or F2 dial is turned. RGAIN BGAIN : : ±0 ±0
F1 dial F2 dial
Select the target menu.
Press the corresponding PRESET MEMORY/ MENU button, and light its indicator. For details on the menus assigned to these buttons, refer to "Table of menu items" (<Operations and Settings> Operating Instructions). The selected menu is displayed on the LCD panel.
3
Change the settings using the F1 dial and F2 dial.
Use the F1 dial and F2 dial to select the menus and change the settings. Use the F1 dial for operations involving the items displayed on the top line of the LCD panel. Use the F2 dial for operations involving the items displayed on the bottom line of the LCD panel.
F1 F2
POWER
ALARM
F1
CAMERA OSD
3
1
MENU PAGE STORE DELETE
1
GAIN/PED
2
R/B GAIN
3
R/B PED
4
AWB/ABB
5
SHUTTER
F2
EXIT
6
DETAIL
7
8
9
10
SYSTEM
SETUP SCENE/MODE CAMERA PRESET MEMORY / MENU
USER1
USER2
1
IRIS AUTO
2
3
4
5
PT ACTIVE
CAMERA STATUS / SELECTION
AUTO TELE ZOOM WIDE
FOCUS/PUSH OTAF
LOW HI PTZ/FOCUS SPEED
PAN/TILT
2
For detailed operations, refer to the Operating Instructions -- <Operations and Settings>.
17
Network settings
This section describes how the unit's network are set.
5
Turn the F1 dial, and display the target setting item.
1. IP ADDRESS 192 168. 000. 009
Note
Correct operation is not possible if the same IP address already exists in the same network. Set the IP addresses in such a way that they do not duplicate any existing IP addresses.
Setting the unit
The unit's settings are established using the [SYSTEM] menu. First, the basic menu operations will be described.
2. SUBNETMASK 255 255. 255. 000
3. GATEWAY 192 168. 000. 001
1 2
Set the MENU button to ON.
Press the MENU button, and light its indicator.
4. MAC ADDRESS
Set the PRESET MEMORY/MENU 10 button (SYSTEM) to ON.
When the button is pressed and its indicator is lighted, the [SYSTEM] menu is displayed on the LCD panel.
6
Turn the F2 dial, and select the setting.
2. SUBNETMASK 255 255. 255. 000
[1]CAMERA CTL
7
Press the F2 dial, and change the setting.
2. SUBNETMASK 255. 255 255. 000
Input all the settings except for the MAC address in four blocks of numerals. When input advances to the last block and the F2 dial is pressed, the IP address is entered. 2. SUBNETMASK 255. 255. 255. 000 The MAC address is merely displayed -- it cannot be changed.
3
Turn the F1 dial, and display the [NETWORK] menu.
[6]NETWORK
4
Press the F1 dial.
1. IP ADDRESS 192 168. 000. 009
Note
In order for the settings to take effect, the unit must be restarted. Turn off the unit's power, and then turn it back on again.
18
Network settings
Setting the IP address On the [SYSTEM] menu, select the [NETWORK] menu, and display [IP ADDRESS]. Select a setting which will not duplicate the IP setting of another device. Setting the subnet mask On the [SYSTEM] menu, select the [NETWORK] menu, and display [SUBNETMASK]. [. . . ] The IP addresses of the remote cameras are not changed.
Memo
If the unit's IP address has been changed using the [IP ADDRESS] item of [NETWORK] on the [SYSTEM] menu, the IP addresses of the camera numbers which were set to "NoAsign" for the [CAM1] to [CAM100] item of [CAMERA CTL] on the [SYSTEM] menu and which are higher than the unit's IP address, will be automatically re-set in the sequence of the camera numbers set to "NoAsign" starting with the lowest number.
33
Connections
Changing the camera numbers
The camera numbers which have been set by "Auto IP setting" can be changed. They are changed by replacing the IP addresses of the current camera numbers with the IP addresses of the camera numbers to be changed.
Changing the IP address of the switcher
The IP address of the switcher which was set by "Auto IP setting" can be changed.
1
1 2
On the [SYSTEM] menu, select [CAMASSIGN], and display [CAM1] to [CAM100]. Select the IP address of the remote camera for the selected camera number.
The tally indicator of the remote camera corresponding to the selected IP address lights. Operate the PAN/TILT lever, and check whether the camera whose camera number is to be changed is being moved. [. . . ]