User manual PANASONIC H98

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC H98. We hope that this PANASONIC H98 user guide will be useful to you.


PANASONIC H98 : Download the complete user guide (2201 Ko)

Manual abstract: user guide PANASONIC H98

Detailed instructions for use are in the User's Guide.

[. . . ] 0kg) Output power:IEC705-88 Test Procedure Specifications subject to change without notice. 0kg) Output power:IEC705-88 Test Procedure Specifications subject to change without notice. ® > WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. it does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. [. . . ] When installing new membrane key board, make sure that the surface of escutcheon base is cleaned sufficiently so that any problems (shorted contacts or uneven surface) can be avoided. Alignment position of membrane key board is as follows; Membrane key board: Right and upper edges Escutcheon sheet: Right and upper edges 3. Low voltage transformer and/or power relays (RY1, RY2) NOTE: Be sure to ground any static electric charge built up on your body before handling the DPC. (A) Using solder wick or a desoldering tool and 30W soldering iron, carefully remove all solder from the terminal pins of the low voltage transformer and/or power relays. NOTE: Do not use a soldering iron or desoldering tool of more than 30 watts on DPC contacts. (B) With all the terminal pins cleaned and separated from DPC contacts, remove the defective transformer/power relays and install new transformer/relays making sure all terminal pins are inserted completely. (C) Remove orifice assembly/Inverter power supply (U) from oven assembly. (Refer page 15) (D) Remove fan blade from the fan motor shaft by pulling it straight out. (F) Separate the fan motor from the orifice assembly by freeing 2 catch hooks on the orifice assembly. Door assembly (A) Remove door C from door E by carefully pulling outward starting from upper right hand corner using a flat blade screwdriver. (C) Open Door E at the opening angle of approximately 10° (Note: The door cannot be removed if the opening angle is greater than 10°). (D) Remove the door from its hinges by pushing the door’s lower hinge pin upward and out. (G) When reassembling door hold door E at the opening angle of approximately 10°. (H) Place the door’s lower hinge pin into the bottom hinge hole. (I) Use your left index finger to support the door’s lower hinge pin while guiding the door’s upper hinge pin into the top hinge hole. After replacement of the defective component parts of the door, reassemble, install, and perform microwave leakage test. Turntable motor (A) Remove the motor cover by breaking off at the 8 spots indicated by arrows with a cutter or the like. (See Figure) NOTE: After breaking off the motor cover, make sure that cut-off portions are properly trimmed off or bend to inside so that no sharp edge will expose to outside. NOTE: After reinstalling the new turntable motor and reconnecting the two lead wires, reinstall the motor cover by rotating it around 180 , tucking the tabs under the base into the 2 provided slots, then screw the single tab to the base using a 4mm X 6mm screw (not provided). NOTE: When installing the steam sensor, make sure that the direction of steam sensor is as shown in figure. Make sure to securely tighten grounding screw from the bottom of chasis (base). Take special care not to touch any lead wire to the aluminum heat sink because it is hot. [. . . ] H97, H98, H99 appears in display window a short time after start key is pressed and there is no microwave oscillation. H97, H98, or H99 appears in display window Check magnetron filament continuity OK refer to componenet test procedures Open Magnetron* Check Inverter input AC voltages at CN702 AC 120V unplug CN702 and measure at lead wire harness side OV DPC board Loose relay wiring Check inverter control signal at CN701, pin 1 and 2 AC3V unplug CN701 and measure at lead wire harness side OV DPC board NOTE: DO NOT try to repair this Inverter Power Supply (U) and also DO NOT RE-ADJUST PRESET VOLUME on the board. It is very dangerous to repair or adjust without sufficient test equipment because this circuit handles very high voltage and very large current. Operating a misaligned Inverter circuit is dangerous due to the very high voltage and current that is produced by this board. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC H98




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC H98 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.