User manual PENTAX MZ-10

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PENTAX MZ-10. We hope that this PENTAX MZ-10 user guide will be useful to you.


PENTAX MZ-10 : Download the complete user guide (3075 Ko)

You may also download the following manuals related to this product:

   PENTAX MZ-10 (94 ko)
   PENTAX MZ-10 (3317 ko)
   PENTAX MZ-10 (12205 ko)
   PENTAX MZ-10 BROCHURE (167 ko)
   PENTAX MZ-10 BROCHURE (12206 ko)
   PENTAX MZ-10 BROCHURE (3317 ko)

Manual abstract: user guide PENTAX MZ-10

Detailed instructions for use are in the User's Guide.

[. . . ] If water should happen to splash on the instrument or the battery, wipe it off immediately and allow it to dry in a dry location. 7 1. Basic Operation 1. 1 Removing the Battery (1) Rotate the knob above the battery pack counter-clockwise. 1. 2 Attaching the Battery (1) Place the channel on the bottom of the battery pack, onto the protrusion of the instrument and push the battery pack down into place. (2) Turn the knob clockwise. 8 1. 3 Turning the Power On and Off To set power on : To shut down: To turn the power supply off, press the I/O key for more than 1 second and then release it. [. . . ] / V. dst. " Switches the screen between MODE A and MODE B. [TARGET] [0 SET] [DISP] [MODE] 10 MODE B [S. FUNC] [ANG SET] PowerTopoExpress Special Functions Brings up the angle setting screen for setting angle-related parameters. (H. ANGLE / %GRADE, H. ANGLE INPUT and R/L REVERSE) Pressing this key twice retains (holds) the horizontal angle shown on the display. Brings up the screen for changing the target constant, temperature, Pressure setting. Switches the screen between MODE A and MODE B. [HOLD] [CORR] [MODE] 11 1. 5 Angle Measurement 1. 5. 1 Horizontal Angle Set the screen MODE A : MODE A screen Control keys for measuring horizontal angle: To set the angle to 0 : To hold the angle : To release HOLD : To input an angle : input value by using : To read clockwise angle : x2 1. 5. 2 Vertical angle To display vertical angle : To read the slope % : 12 1. 6 Distance Measurement Set the screen MODE A : MODE A screen (MZ-10N models only) 1. 6. 1 Select your target Select target type (measurement mode): (Prism) (Reflector-less) NOTE: The selected target is maintained until next time you change 1. 6. 2 Distance measurement For a single shot measurement : For tracking measurement : NOTE: The number of shots can be defined. The default is "one time". The measuring modes activated by the above operations can be also changed. 1. 6. 3 Changing Target constants The default constants are: Prism : -30mm Reflector-less : always 0mm (MZ-10N models only) Before changing the constants, set Target Constant in the Initial Setting to "INPUT"mode: x2 To change Prism constant: input value by using: 13 1. 6. 4 Input Temperature and Atmospheric pressure To Input temperature : x2 input value by using: To Input atmospheric pressure: X3 input value by using: 1. 6. 5 Adjusting LCD contrast + 1. 6. 6 Adjusting Illumination brightness for LCD or + for Reticle or + or 14 2. Changing Instrument settings 2. 1 Help menu While the screen is in MODE A or MODE B, Select a desired item by or Change the setting NOTE: Some items have sub-menus where the selecting procedure by using direction keys is again repeated. 2. 2 Instrument setting items HELP menu list PRISM CONST ATM CORR SHOT COUNT CRV/ REF CORR ATM CORR DISP MIN UNIT ANG. UNIT PRESS UNIT BAUD RATE DATA LENGTH PARITY BITS STOP BITS SIGNAL CONTROL XON/ XOFF THROUGH COMMAND (-30mm), 0mm, INPUT (ATM INPUT), ppm INPUT, NIL (1 time), 3 times, 5 times, INPUT (01 times), input (0. 14), 0. 2, NIL (OFF), ON (FINE), COARSE (Z. 0, COMPASS (OFF), ON (10 MIN), 20 MIN, 30 MIN, NIL (3 MIN), 5 MIN, 10 MIN, NIL (ON), OFF (Centigrade), Fahrenheit (hPa), mmHg, inchHg (m), ft, ft+ inch (DEG), DEC, GRD, MIL (1200), 2400, 4800, 9600 (8), 7 (NIL), EVEN, ODD (1), 2 (ON), OFF (ON), OFF (NIL), a, b, c, d, e, f 15 3. Warning and Error Messages Warning Message Out of tilt range Meaning What to do Re-level the instrument. Operation, maintenance or adjustment other than those specified in this instruction manual may result in hazardous radiation exposure. If the inputted PN already exists in the memory, then the corresponding point information (coordinate & point code) is displayed in the screen. The result of Free Station, prior to stakeout, is automatically set in the each field of Station Setup. 8. 2 Orientation (Station Point H. Angle Setup) To input a given angle: input value by using MEASUREMENT SCREEN Or to set the angle 0°: MEASUREMENT SCREEN Or to calculate by the Back Sight Point: input value or select from the list aim Back Sight Point MEASUREMENT SCREEN 27 8. 3 Measurement To select the Target type: (MZ-10N models only) x2 Repeat Until the desired target type is selected NOTE: You can check the selected target type at the left side of the Battery mark in the top line of the screen. To measure: Or to start tracking: x2 NOTE: Shot count can be changed by using To input the point information: select by input value by using RETURN TO THE MASUREMENT SCREEN input PC SAVE x2 or To save the point information: ( next measurement ) 28 Or to measure and save: ( next measurement ) NOTE: The Point number is automatically incremented or decremented to make rapid continuous measurements possible. 8. 4 Offset Measurement For Radial Offset (the horizontal distance offset along the line of measurement): MEASUREMENT SCREEN input value by using RETURN TO THE MASUREMENT SCREEN For Tangential Offset: MEASUREMENT SCREEN input value by using RETURN TO THE MASUREMENT SCREEN X3 For Distance Offset (slope distance): MEASUREMENT SCREEN input value by using RETURN TO THE MASUREMENT SCREEN X2 29 NOTE: The Offset values are cleared once the measurement is saved. 8. 5 Remote measurement To enter the Remote mode: MEASUREMENT SCREEN X2 RETURN TO THE MEASUREMENT VALUES ARE UPDATED BY TURNING THE TELESCOPE X2 select by input value by using or ( next measurement ) input PC or MEASUREMENT SCREEN X2 REMOTE MODE MEASUREMENT VALUES ARE UPDATED BY TURNING THE TELESCOPE select by input value by using or ( next measurement ) input PC 30 NOTE: Remote values are calculated based on the assumption of the reference plane. Three types of the reference plane are available in PowerTopoExpress; Cylindrical surface, Fixed plane (default) and Rotated plane. To change the reference plane type: PowerTopoExpress MAIN MENU X4 or Select by To quit the Remote mode: MEASUREMENT SCREEN X2 9. Polar Coordinate Measurement PowerTopoExpress MAIN MENU POLAR CORRD. 9. 1 Station Point Setup To input the point information: input a Point Name by using H. ANGLE SETUP repeat to input value or confirm "ppm" 31 NOTE: Input items are PN (point name), IH (instrument height), PC (point code), TEMP (temperature), PRESS (atmospheric pressure) and ppm. "TEMP" and "PRESS" can be input only when "Atmospheric Correction" is set to "ATM INPUT". "ppm" can be input only when "Atmospheric Correction" is set to "ppm INPUT". The input item (cursor position) may be selected by 9. 2 Orientation (Station Point H. Angle Setup) Only when the orientation of the horizontal angle is required, proceed according to the following procedure. Otherwise, just pass this step by To input a given angle: input value by using MEASUREMENT SCREEN Or to set the angle 0°: MEASUREMENT SCREEN Or to calculate by the Back Sight Point: select Start Point from the list select End Point from the list MEASUREMENT SCREEN X2 32 9. 3 Measurement To select the Target type: (MZ-10N models only) x2 Repeat Until the desired target type is selected NOTE: You can check the selected target type at the left side of the Battery mark in the top line of the screen. To measure: Or to start tracking: x2 NOTE: Shot count can be changed by using To input the point information: input a Point Name by using x2 input value by using RETURN TO THE MASUREMENT SCREEN input PC To save the point information: ( next measurement ) 33 Or to measure and save: ( next measurement ) NOTE: The point number is automatically incremented or decrimented for rapid continuous measurements. 9. 4 Offset measurement For Radial Offset (the horizontal distance offset along the line of measurement): MEASUREMENT SCREEN input value by using RETURN TO THE MASUREMENT SCREEN For Distance Offset (slope distance): MEASUREMENT SCREEN input value by using RETURN TO THE MASUREMENT SCREEN NOTE: The Offset values are cleared once the measurement is saved. 34 10. Free Stationing PowerTopoExpress MAIN MENU input Inst. Height (IH) by using KNOWN POINT SETUP X3 10. 1 Known Point Setup To select from the memory: select the point by using , MEASUREMENT SCREEN Or input PN which is already stored in memory to call and display the known coordinate 10. 2 Measurement Select the target type and measure: Repeat Until the desired target type is selected (MZ-10N models only) NOTE: You can check the selected target type at the left side of the Battery mark in the top line of the screen. [. . . ] Stake Out (Point to Line) "Point to Line" gives the distances between SOP and Int. P, A and Int. P, B and Int. P. PowerTopoExpress MAIN MENU STATION POINT SETUP X4 12. 1 Station Point Setup Select the point from the stored data: select the point by using , H. ANGLE SETUP NOTE: The result of Free Station, prior to stakeout, is automatically set in the each field of Station Setup. 12. 2 Orientation (Station Point H. Angle Setup) To input a given angle: input value by using POINT A SETUP Or to set the angle 0°: POINT A SETUP 39 Or to calculate by the Back Sight Point: input value or select from the list aim Back Sight Point POINT A SETUP 12. 3 Point A Setup To input values: input a Point Name by using X-Z, PC(point code) SAVE or POINT B SETUP repeat to input value input PC SAVE Or to select from the memory: select the point by using , POINT B SETUP 12. 4 Point B Setup To input values: input a Point Name by using 40 X-Z, PC(point code) SAVE or MEASUREMENT repeat to input value input PC SAVE Or to select from the memory: select the point by using , MEASUREMENT 12. 5 Point To Line Measurement To select the Target type: Repeat Until the desired target type is selected (MZ-10N models only) To measure in Tracking mode: (move the target to the desired position) x2 To quit measurement (position the target accurately) To confirm the position of the stake: Input PN, PH and PC RETURN TO STAKEOUT MASUREMENT SCREEN x2 41 13. INVERS PowerTopoExpress MAIN MENU X3 To input SP (Station point): input a Point Name by using X-Z, PC(point code) SAVE or Input End point repeat to input value input PC RESULT SCREEN 14. Area Calculation To start area calculation: PowerTopoExpress MAIN MENU X3 select points of the polygon by repeating select RESULT SCREEN To return to the calculation menu screen: RESULT SCREEN CALCULATION MENU SCREEN x2 42 NOTE: This function calculates the length of 2D contour of a p o l yg o n , a n d t h e 2 D s u r f a c e ( a r e a ) o f t h e p o l yg o n . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PENTAX MZ-10




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PENTAX MZ-10 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.