User manual POLTI LECOLOGICO AS805
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual POLTI LECOLOGICO AS805. We hope that this POLTI LECOLOGICO AS805 user guide will be useful to you.
You may also download the following manuals related to this product:
POLTI LECOLOGICO AS805 (1011 ko)
POLTI LECOLOGICO AS805 (1397 ko)
Manual abstract: user guide POLTI LECOLOGICO AS805
Detailed instructions for use are in the User's Guide.
[. . . ] It is the flow of water contained in the special filter and its bubble that imprison dirt, preventing all contact with dust, and avoiding dispersal of dust back into the air. Lecologico has a special extra powerful washable HEPA filter, previously used only in professional applications requiring the utmost hygiene. This filter stops even the finest dust, pollens, dust mites and other micro-organisms and is easily rinsed clean when dirty. Main switch Cable winder switch Carry handle Container handle Rear wheels "EcoActive-Filter" water container MAX level (fig. 4) Air outlet grid Cover on filter housing (fig. 16) Lever for opening filter cover (fig. 16) Hepa filter (fig. 18) Hepa filter retainer (fig. 17) "Dual filter" assembly (fig. 17) Tool holder housing Casters Power cable plug Indicator lights Connection "Eco Active Filter" water filter Filter cage cover Filter body with fine mesh Sponge filter Filter nozzle On/off and increased suction switch Decreased suction switch ACCESSORIES A. [. . . ] To restore the appliance to the pause position, hold down button (18) for more than one second, then release it.
CORRECT USE OF THE PRODUCT
This appliance is intended for vacuuming liquids and solids in accordance with the descriptions and instructions provided in this manual. Please read
D RY L I Q U I D S U C T I O N
The appliance is used in the same way to vacuum up dust or limited amount of liquids. If the water is very dirty, replace it as described in the section on
ENGLISH
LECOLOGICO AS 805
"Emptying and cleaning the water container". When the dirt collected in the water container (6) reaches the maximum permitted level, the safety float (W) will automatically stop the suction. After 10 seconds the appliance will automatically pause and the four indicator lights (14) will start flashing. To resume cleaning, perform the operations described in the section on emptying and cleaning the container, then top up the water level in the container.
The tube is about 60 cm long when closed, 1 m when extended to its greatest length. To increase or decrease length, press the catch positioned as shown in fig. Jointed tube (M) The handy jointed tube is particularly adaptable as it can be folded and adjusted to suit the task in hand. It is handy for cleaning spots that are hard to reach with traditional tools, such as high shelves, the tops of wardrobes, underneath furniture, etc. Using the joker brush (B) The Joker brush may be used to vacuum up solids or a limited amount of liquids on any kind of surface. Using the hardwood floor tool (B1) and the hardwood floor wheel cover (P) Position the Joker brush (B) on the hardwood floor tool (B1) as shown in figure 13. Apply the tool to the brush, following the direction of the arrow so that it is aligned properly and they connect together. To release the hardwood floor tool from the Joker brush, pull the two levers on the sides of the frame outward and lift the brush (fig. You should also use wheel covers (P) to prevent damage to your hardwood floor. To assemble wheel covers, simply fit together the two joints (P1) in the housings on the bottom of the appliance (fig. 14). To release the tool, simply press the two joints (P1) inward and lift off the wheel cover. Using the universal brush (C) Connect the brush to the telescopic tube. If you move the selector on the brush (C1) and press with a foot, you can change the suctioning surface without bending down. The position with bristles extended is recommended for all non-carpeted floors. Multipurpose nozzle (E) The multipurpose nozzle is recommended for cleaning upholstery surfaces such as the joints of sofas, armchairs, mattresses, car upholstery, etc. Lance for cleaning corners/skirting boards (F) radiator brush (L) The lance (F) is recommended for thorough vacuum cleaning of hard-to-reach spots such as skirting boards and folds in sofas, armchairs, upholstered furniture and car upholstery. Apply the radiator
BIOECOLOGICO
For sanitisation we recommend use of Bioecologico, an anti-bacterial agent scented with natural antiallergenic substances. [. . . ] · Leakage of water when suctioning up liquids: The float may be blocked up. Clean the filter assembly and make sure that the water level in the container is correct.
· Brown: Live The wire which is coloured BLUE must be connected to the Terminal which is marked with the letter "N" or coloured BLACK. The wire which is coloured BROWN must be connected to the Terminal which is marked with the letter "L" or coloured RED. It is important that the outer sheath is clamped correctly into the 3-pin plug. [. . . ]