User manual RESPIRONICS SLEEP EASY

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RESPIRONICS SLEEP EASY. We hope that this RESPIRONICS SLEEP EASY user guide will be useful to you.


RESPIRONICS SLEEP EASY : Download the complete user guide (1983 Ko)

Manual abstract: user guide RESPIRONICS SLEEP EASY

Detailed instructions for use are in the User's Guide.

[. . . ] SleepEasy ® User Manual Would you like a free travel bag for your SleepEasy?If so, go to http://sleepeasy. respironics. com/register to register your product and receive your SleepEasy travel bag. A nominal charge for shipping and handling will be applied. This SleepEasy device is covered by one or more of the following patents: U. S. All rights reserved. Table of ConTenTs Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] ThenextscreentoappearistheStandbyscreen, showninFigure4­2. SeeSection4. 5for instructions on how to navigate the display screens. fIgUre 4­2 sTandby sCreen Press the button to turn on the airflow. 3. fIgUre 4­3 operaTe sCreen TheOperatescreenshowsthecurrentCPAPsetting. User ManUal 17 5. Makesurethatnoairisleakingfromyourmaskintoyoureyes. Ifitis, adjustthemaskand headgear until the air leak stops. Asmallamountofmaskleakisnormalandacceptable. Correctlargemaskleaksoreye irritation from an air leak as soon as possible. If you are using the device in bed, try placing the tubing from the device over your headboard. If you are having trouble with your mask, refer to the instructions supplied with the mask. You must remove the mask and patient circuit before you get out of bed. NOTE: NOTE: 4. 2 UsIng The raMp feaTUre button to activate the Ramp feature, if your provider has enabled YoucanpresstheRAMP this feature. 4. 2. 1 raMp feaTUre The device is equipped with an optional ramp feature that your home care provider can enable or disable. This feature reduces the air pressure when you are trying to fall asleep and then gradually increases (ramps) the pressure until your prescription setting is reached, allowing you to fall asleep more comfortably. Iframpisenabledonyourdevice, afteryouturnontheairflow, presstheRAMPbuttononthe topofthedevice. YoucanusetheRAMPbuttonasoftenasyouwishduringthenight. NOTE: Iftherampfeatureisdisabled, nothingwillhappenwhenyoupresstheRAMPbutton. 4. 2. 2 seTTIng raMp ThisscreenisenteredbypressingandholdingtheRAMP button for 3 seconds. The Ramp StartingPressureScreenwillappear, Figure4-4. Itcanbeenteredfromeitherthestandbyor operate screen. fIgUre 4-4 raMp sTarTIng pressUre sCreen Youcanincreaseordecreasetherampstartingpressurein0. 5cmH2O increments by pressing the + or ­buttons. Thedefaultsettingis4cmH2O. Youcanadjustthesettingfrom4cmH2OtotheCPAP pressure setting. NOTE: This screen will not display if your provider has not enabled Ramp on your device. button to return to the Standby After you have finished modifying this screen, press the screen. 18 User ManUal 4. 3 UsIng The heaTed hUMIdIfIer feaTUres 4. 3. 1 heaTed hUMIdIfIer feaTUre TheIntegratedHeatedHumidifierisafeaturethatmayreducenasaldrynessandirritationby adding moisture and heat to the airflow. This feature can be enabled or disabled by your home care provider. 4. 3. 2 seTTIng heaTed hUMIdIfIer Iftheheatedhumidifierisenabledonyourdevice, presstheHEAT button on the top of the device. TheHeatSettingscreenwillappear, Figure4-5. Youcanenterthisscreenfromeitherthe standby or operate screen. NOTE: If the heated humidifier feature is disabled by the home care provider, nothing will happenwhenyoupresstheHEATbutton. fIgUre 4-5 heaT seTTIng sCreen Youcanincreaseordecreasethehumidifierheatsettingsbypressingthe+or­buttons. Thepossible settingsarefrom0(off)to5whichisthehighestsetting. NOTE: This screen will not display if your provider has not enabled the humidifier on your device. button to return to the Standby After you have finished modifying this screen, press the screen. 4. 4 alTITUde seTTIng ToaccesstheAltitudeSettingscreen, youpressandholdboththeRAMP button and the HEAT button simultaneously for 3 seconds. NOTE: You can only enter this screen from the standby screen. fIgUre 4-6 alTITUde seTTIng sCreen User ManUal 19 Thisscreenallowsyoutomodifythealtitudeadjustmentsetting. Pressthe+or­buttonstoincreaseor decreasethesettingbyincrementsof1: · 1=lessthan<2500ft. WARNING: If you incorrectly set the manual altitude setting, the pressure may be too high or too low, depending on your location. 4. 5 dIsplay sCreens YoucanviewthesetpressureontheActiveDisplayscreen(Operatescreen), aswellasthe followinginformationonthePatientDatascreens: · Therapyusagehours(standbyscreen) · Blowerhours · Numberofsessionsgreaterthan4hours · Compliancechecksum · Currentaltitudesetting 4. 5. 1 NOTE: navIgaTIng The dIsplay sCreens You can only enter these screens from the standby screen. Usethe+and-buttonstonavigatethedisplayscreens. 4. 5. 2 vIeWIng daTa on The paTIenT daTa sCreens 1. Therapy Usage Hours (Standby Screen) This screen displays the amount of time that the device provided therapy (with the blower on and the patient connected). The decimal digit is displayedifuserhoursarelessthan10000soitcanbedisplayedwith0. 1 hourresolution. Otherwise, thevaluesbetween10000and99999hours can be displayed. Your home care provider may periodically ask you for this information. ThefollowingdescribesthePatientDatascreens. 20 User ManUal 2. Blower Hours Screen This screen displays the amount of time that the blower has been active over the life of the device. [. . . ] The user of this device should make sure it is used in such an environment. IMMUnITy TesT IeC 60601 TesT level CoMplIanCe level eleCTroMagneTIC envIronMenT -gUIdanCe Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 150 kHz to 80 MHz 3 V/m 80 MHz to 2. 5 GHz 3 Vrms Recommended separation distance d = 1. 2 d = 1. 2 d = 2. 3 80 MHz to 800 MHz 800 MHz to 2. 5 GHz 3 V/m where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site surveya, should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RESPIRONICS SLEEP EASY




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RESPIRONICS SLEEP EASY will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.