[. . . ] Digital Storage Oscilloscopes
TDS2000C Series Data Sheet
Ease-of-Use Features
16 Automated Measurements, and FFT Analysis for Simplified Waveform Analysis Built-in Waveform Limit Testing Automated, Extended Data Logging Feature Autoset and Signal Auto-ranging Built-in Context-sensitive Help Probe Check Wizard Multiple-language User Interface 5. 7 in. (144 mm) Active TFT Color Display Small Footprint and Lightweight Only 4. 9 in. [. . . ] Limit Test The oscilloscope can automatically monitor source signals and output Pass or Fail results by judging whether the input waveform is within predefined
boundaries. Specific actions can be triggered on violation including stopping waveform acquisition, stopping Limit Test functions, saving the failed waveform data or screen image to a USB memory device, or any combination of the above. This is an ideal solution for manufacturing or service applications where you need to make decisions quickly.
Flexible Data Transfer The USB host port on the front panel enables you to save your instrument settings, screenshots, and waveform data in a flash. The built-in data logging feature means you can set up your oscilloscope to save user-specified triggered waveforms to a USB memory device for up to 8 hours.
www. tektronix. com
3
Data Sheet
and waveform data into the stand-alone desktop application or directly into Microsoft Word and Excel. Alternatively, if you prefer not to use your PC, you can simply print your image directly to any PictBridge-compatible printer.
Connect Your Bench for Intelligent Debug
Every TDS2000C Series oscilloscope ships with an included copy of the Limited Tektronix Edition of National Instrument's LabVIEW SignalExpress for basic instrument control, data logging, and analysis. SignalExpress supports the range of Tektronix bench instruments*2 enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design.
Easily capture, save, and analyze measurement results with included National Instrument's LabVIEW SignalExpress, Limited Tektronix Edition software.
Performance You Can Count On
In addition to industry-leading service and support, every TDS2000C Series oscilloscope comes backed with a Lifetime Warranty*1 as standard.
*1 Limitations apply. *2 For a complete listing of Tektronix instruments supported by NI LabVIEW Signal Express, visit www. tektronix. com/signalexpress.
Easy PC Connectivity Easily capture, save, and analyze measurements results by connecting to your PC with the rear-panel USB device port and the included copy of OpenChoice PC Communications Software. Simply pull screen images
4
www. tektronix. com
Digital Storage Oscilloscopes -- TDS2000C Series
Characteristics
TDS2000C Series Digital Storage Oscilloscopes
TDS2001C TDS2002C TDS2004C TDS2012C TDS2014C TDS2022C TDS2024C
Display (QVGA LCD) Bandwidth*3 Channels External Trigger Input Sample Rate on Each Channel Record Length Vertical Resolution Vertical Sensitivity DC Vertical Accuracy Vertical Zoom Maximum Input Voltage Position Range Bandwidth Limit Input Coupling Input Impedance Time Base Range Time Base Accuracy Horizontal Zoom
I/O Interfaces
TFT 50 MHz 2
TFT 70 MHz 2
TFT 70 MHz 4
TFT 100 MHz 2 Included on all models 2. 0 GS/s
TFT 100 MHz 4
TFT 200 MHz 2
TFT 200 MHz 4
500 MS/s
1. 0 GS/s
1. 0 GS/s
2. 0 GS/s
2. 0 GS/s
2. 0 GS/s
2. 5k points at all time bases on all models 8 bits 2 mV to 5 V/div on all models with calibrated fine adjustment ±3% on all models Vertically expand or compress a live or stopped waveform 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz 2 mV to 200 mV/div +2 V >200 mV to 5 V/div +50 V 20 MHz for all models AC, DC, GND on all models 1 M in parallel with 20 pF 5 ns to 50 s/div 2. 5 ns to 50 s/div 2. 5 ns to 50 s/div 50 ppm Horizontally expand or compress a live or stopped waveform USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all PictBridge-compatible printers Optional (2) 2. 5k point reference waveforms (2) 2. 5k point (2) 2. 5k point (4) 2. 5k point (2) 2. 5k point 64 GB 96 or more reference waveforms per 8 MB 10 front-panel setups 4000 or more front-panel setups per 8 MB 128 or more screen images per 8 MB (the number of images depends on file format selected) 12 or more Save All operations per 8 MB A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform) (4) 2. 5k point (2) 2. 5k point (4) 2. 5k point
5 ns to 50 s/div
5 ns to 50 s/div
2. 5 ns to 50 s/div
2. 5 ns to 50 s/div
USB Ports GPIB
Nonvolatile Storage
Reference Waveform Display Waveform Storage without USB Flash Drive Maximum USB Flash Drive Size Waveform Storage with USB Flash Drive Setups without USB Flash Drive Setups with USB Flash Drive Screen Images with USB Flash Drive Save All with USB Flash Drive
*3 Bandwidth is 20 MHz at 2 mV/div, all models.
www. tektronix. com
5
Data Sheet
Acquisition Modes
Mode Description
Waveform Math
Characteristic Description
Peak Detect Sample Average Single Sequence Roll
High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 s/div to 50 s/div Sample data only Waveform averaged, selectable: 4, 16, 64, 128 Use the Single Sequence button to capture a single triggered acquisition sequence At acquisition time base settings of >100 ms/div
Operators FFT
Add, Subtract, Multiply, FFT Windows: Hanning, Flat Top, Rectangular 2048 sample points
Sources 2-channel models CH1 CH2, CH2 CH1, CH1 + CH2, CH1 × CH2 4-channel models CH1 CH2, CH2 CH1, CH3 CH4, CH4 CH3, CH1 + CH2, CH3 + CH4, CH1 × CH2, CH3 × CH4
Autoset Menu Trigger System
Characteristic Description
Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset.
Signal Type Autoset Menu Choices
Trigger Modes
Auto, Normal, Single Sequence
Trigger Types
Trigger Description
Edge (Rising/Falling) Video Pulse Width (or glitch)
Conventional level-driven trigger. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM) Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s
Square Wave Sine Wave Video (NTSC, PAL, SECAM)
Single Cycle, Multicycle, Rising or Falling Edge Single Cycle, Multicycle, FFT Spectrum Field: All, Odd, or Even Line: All or Selectable Line Number
Autorange
Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal exhibits large changes.
Display Characteristics
Characteristic Description
Trigger Source
Characteristic Description
2-channel Models 4-channel Models
CH1, CH2, Ext, Ext/5, AC Line CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line
Display Interpolation Display Types Persistence Format
QVGA Active Color TFT Sin(x)/x Dots, vectors Off, 1 s, 2 s, 5 s, infinite YT and XY
Trigger View
Displays trigger signal while Trigger View button is depressed.
Multiple-language User Interface and Context-sensitive Help
Characteristic Description
Trigger Signal Frequency Readout
Provides a frequency readout of the trigger source.
Languages Available
English, French, German, Italian, Japanese, Korean, Portuguese, Russian*4, Simplified Chinese, Spanish, Traditional Chinese
*4 Requires Russian firmware, indicated by "RUS" suffix.
Cursors
Characteristic Description
Environmental and Safety
Characteristic Description
Types Measurements
Amplitude, Time T, 1/T, V
Automatic Waveform Measurements
Period, Frequency, +Width, Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, RMS, Cycle RMS, Cursor RMS, Duty Cycle, Phase, Delay
Temperature Operating Nonoperating Humidity Operating and nonoperating Altitude Operating and nonoperating Electromagnetic Compatibility Safety
0 to +50 °C 40 to +71 °C Up to 80% RH at or below +40 °C Up to 45% RH up to +50 °C Up to 3, 000 m Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Australian EMC Framework UL61010-1:2004, CSA22. 2 No. *6 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. [. . . ] Information in this publication supersedes that in all previously published material. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. [. . . ]