User manual WHIRLPOOL HBN G720 W INSTRUCTION FOR USE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL HBN G720 W. We hope that this WHIRLPOOL HBN G720 W user guide will be useful to you.


WHIRLPOOL HBN G720 W INSTRUCTION FOR USE: Download the complete user guide (1925 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL HBN G720 W KURZANLEITUNG (756 ko)
   WHIRLPOOL HBN G720 W PROGRAM CHART (752 ko)

Manual abstract: user guide WHIRLPOOL HBN G720 WINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] NUTID HGA3K GB DE DE AT DE ENGLISH AT DEUTSCH 4 17 Language, Sprache Country, Land ENGLISH 4 Safety information Product description Daily use Helpful hints and tips Maintenance and cleaning What to do if Table of contents Your safety and the safety of others are very important. This manual and the appliance itself provide important safety messages, to be read and observed at all times. This is the safety alert symbol, pertaining to safety, which alerts users to potential hazards to themselves and others. All safety messages will follow the safety alert symbol and either the terms: DANGER Indicates a hazardous situation which, if not avoided, will cause serious injury. [. . . ] In the unlikely event that an operation or repair is carried out by an unauthorised technician, always request certification of the work carried out and insist on the use of original spare parts. Failure to comply with these instructions may compromise the safety and quality of the product. ENGLISH 9 Injector table Category II2H3B/P (AT) II2ELL3B/P (DE) Type of gas used Type of burner Injector Nominal Nominal marking heating consumcapacity ption kW 140 97 74 B 3, 50 1, 65 1, 00 333 l/h 157 l/h 95 l/h Reduced Gas pressure heat (mbar) capacity kW min. 1, 55 0, 35 0, 30 NATURAL GAS (Methane) G20 wok semi-rapid auxiliary 17 20 25 *NATURAL GAS (Methane) G25 LIQUEFIED PETROLEUM GAS (Butane) G30 (Propane) G31 wok semi-rapid auxiliary 149 105 A 82 B 3, 50 1, 65 1, 00 388 l/h 183 l/h 1 1 l/h 1 1, 55 0, 35 0, 30 18 20 25 wok semi-rapid auxiliary 85 60 B 45 3, 50 1, 65 1, 00 254 g/h 120 g/h 73 g/h 1, 90 0, 45 0, 35 42, 5 50 57, 5 Type of gas used Model configuration Nominal heating Total nominal capacity kW consumption Air necessary (m3) for combustion 1 m3 of gas 9, 52 8, 187 30, 94 G20 20 mbar *G25 20 mbar G30/G31 50 mbar 3 gas 3 gas 3 gas 6, 15 6, 15 6, 15 585 l/h 682 l/h 447 g/h Electric Power: 230 V ~ 50 Hz *Not foreseen for Austria ENGLISH 10 Technical data Dimensions Width (mm) Height (mm) Length (mm) Voltage (V) The technical information are situated in the rating plate on the bottom side of the appliance and in the energy label. 770 47 350 230 After unpacking the hob, make sure that it has not been damaged during transport. In the event of problems, contact the dealer or your nearest After-sales Service. Technical information for the installer -- This product can be embedded in a worktop 20 to 60 mm thick. -- If there is no oven beneath the hob, insert a separator panel that has a surface at least equal to the opening in the work surface. This panel must be positioned at a maximum distance of 150 mm below the upper surface of the work surface but, in no case less than 20 mm from the bottom of the hob. -- Before installation, make sure that: -- the local gas delivery conditions (nature and pressure) are compatible with the settings of the hob (see the rating plate and injector table); -- the outer surfaces of the furniture or appliances adjacent to the hob are heat Installation resistant according to local regulations; -- This appliance is not connected to a fume exhaust device. It shall be installed in accordance with current installation regulations. Particular attention shall be given to the relevant requirement regarding ventilation. -- Combustion products are discharged outdoors through specific hoods or wall and/or window mounted electrical fans. gas connection This operation must be performed by a qualified technician. The gas supply system must comply with local regulations to the relavant gas standard. -- You can find specific local regulations for some countries in the paragraph -- “Reference to Local Regulations”. If no information concerning your Country is given, please ask details to a qualified technician. Use pressure regulators suitable for the gas pressure indicated in the Instruction. -- The gas nozzles must be changed by After Sales Service or a qualified technician. -- Nozzles not supplied with the appliance must be ordered from After Sales Service. NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go. IMPORTANT: should you experience difficulty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner tap if found to be faulty. [. . . ] € Damage to the following parts: ceramic glass, accessories, crockery and cutlery baskets, feed and drainage pipes, seals, lamps and lamp covers, screens, knobs, casings and parts of casings. Unless such damages can be proved to have been caused by production faults. € Cases where no fault could be found during a technician’s visit. € Repairs not carried out by our appointed service providers and/or an authorized service contractual partner or where nonoriginal parts have been used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL HBN G720 W




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL HBN G720 W will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.