User manual CANDY PVC400X
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CANDY PVC400X. We hope that this CANDY PVC400X user guide will be useful to you.
Manual abstract: user guide CANDY PVC400X
Detailed instructions for use are in the User's Guide.
[. . . ] The size of these openings must be at least 300 cm2 and placed as shown in fig. ONLY)
Warning - this appliance must be earthed This appliance is designed for domestic use only. Connection to the mains supply must be made by a competant electrician, ensuring that all current regulations concerning such installations are observed. The appliance must only be connected to a suitably rated spur point, a 3 pin 13 amp plug/socket is not suitable. [. . . ] This appliance must be installed in accordance with applicable regulations and should only be used in well-ventilated locations. Suitable location A gas-powered cooking appliance produces heat and humidity in the area in which it is installed. For this reason you should ensure good ventilation either by keeping all natural air passages open or by installing an extractor hood with an exhaust flue. Intensive and prolonged use of the appliance may require extra ventilation, such the opening of a window or an increase in speed of the electric fan, if you have one. If a hood cannot be installed, an electric fan should be fitted to an outside wall or window as long there are air vents in the area. The electric fan should be able to carry out a complete change of air in the kitchen 3-5 times every hour. The installer should follow the relavant national standards.
GAS CONNECTION (FOR U. K. ONLY)
The labels on the Hob indicate the types of gas that can be used. It is possible to use other types of gas after carrying out simple modifications. Warning: If gas can be smelt in the vicinity of this appliance turn off the gas supply to the appliance and call the engineer directly. Do not search for a leak with a naked flame.
GB IE
33
34
GB IE
ELECTRICAL CONNECTION
Check the data on the rating plate, located on the outside of the unit, to ensure that the supply and input voltage are suitable. 6
35
36
IE GB
Table of gas consumption
G20/G25 G30 G31 G20 20mbar G30 29mbar G31 37mbar
1W = 0, 860 kcal/h
G25
Quota «X» depending on type of gas
G20 G30 G25 G31
When you have carried out the new gas regulation, replace the old gas rating plate on your appliance with one (supplied with hob) suitable for the type of gas for which it has been regulated.
Working burner large medium double ring maxi
Ø injector Ø injector 1/100 mm 1/100 mm 120 80 93 61 2x94 2x65 2x94 2x65
Qn kW 2, 65 1, 5 3, 3 3, 3
l/h G20 252 143 314 314
g/h G30 193 109 238 238
g/h G31 189 107 236 236
Qn kW 2, 5 1, 45 3, 1 3, 1
l/h G25 277 161 343 343
Qmin. 5 mm 7 mm 15 mm 15 mm
USE OF HOB
USER INSTRUCTIONS
This appliance must only be used for the purpose for which it is intended, domestic cooking, and any other use will be considered improper and could therefore be dangerous. The Manufacturer will not be responisble for any damage or loss resulting from improper use.
SETTING OF THE GAS BURNERS
When the jets have been changed it is necessary to set the correct air gap by keeping to the setting "X" as shown in the table " gas consumption" fig 7. Warning the value of ` X ` setting varies in relation to the size of gas burner and type of gas chosen. A good flame must be of medium length (fig. 8B), excessive air will cause the flame to be short and with sharp colour (fig. 8C): in this case it is necessary to extend out the tube for the air setting from the burner body, if there is insufficient air the flame will appear weak and long (fig. 8A): in this case push the tube of the air setting back into the burner body. 7).
For dimensions «X» see table of gas consumption
BURNER FIXING SCREW SMALL MEDIUM LARGE
USING THE GAS BURNER
To ignite the burners, place a lighted taper close to the burner, press in and turn the control knob anti-clockwise. If the burners have not been used for a couple of days, wait for a few seconds before lighting the burner, this will allow any air present in the pipes to escape. For appliances fitted with electronic ignition carry out the following: · push in and turn the knob anticlockwise to the 5 symbol. For hobs fitted with automatic ignition simply push in and turn the knob to the 5 symbol. The ignition system will continue to generate sparks as long as the gas tap is being pressed. [. . . ] Turning the screw clockwise reduces the gas flow, whilst turning it anticlockwise increases the flow Use this adjustment to obtain a flame of approximately 3 to 4 mm in length and then replace the control knob. When the gas supply available is LPG (Bottle gas)- the screw to set the idle flame must be turned (clockwise) to the end stop. 9
GB IE
37
38
IE GB
If over the years the gas taps become stiff to turn it is necessary to lubricate them. Such operation must be carried out only by qualified Service Engineers. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY PVC400X
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY PVC400X will begin.