[. . . ] 845 Larch Avenue Elmhurst, Illinois 60126-1196 www. liftmaster. com
Radio Receiver Included
Mega ARM Tower
Models:
MADCBB, MATDCBB, MASDCBB & MASTDCBB
(MEGA ARM, MEGA ARM TOWER, MEGA SPRINT & MEGA SPRINT TOWER)
1/2 HP COMMERCIAL DUTY PARKING GATE OPERATOR
INSTALLATION AND SERVICE MANUAL
IMPORTANT: Read and understand Warranty Page first. Use (2) LiftMaster 12Vdc 7AH (Part # MBAT).
TA B L E O F C O N T E N T S
INTRODUCTION
Safety Symbol and Signal Word Review . . 16 SEQUENCE ACCESS MANAGEMENT SYSTEM (SAMS)
SAMS With Other Operators . . 12
2
INTRODUCTION
WARNING
Mechanical
IMPORTANT NOTE
CAUTION WARNING WARNING
Electrical
· BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. [. . . ] Now run the gate open and close with the S3 manual switch making sure that the mechanism travels in the proper 90 degrees desired. Once you are totally sure you have the correct operation, you can install the arm INSTALLATION NOTE: ARMS LONGER THAN 12' MUST USE THE PROPER COUNTER WEIGHT. FIGURE 1
S1
ON
12345678
S1, #7 to be turned ON before power up to enable reverse of arm.
FIGURE 2
Acc+ AccBlack
Battery Red Xfmr Motor
Yellow
Orange Blue
FIGURE 3
Arm shown in reversed direction.
Cam Arm
Output Shaft of Gear Box
9
TIMERS AND MODE SELECTIONS S1 & S2
MODE SELECTIONS - SWITCH PACK S1 (5-8)
SWITCH 5: ON -Will allow J5 input #4 to operate as a pulse open/pulse close function. SWITCH 6: ON -Will fire relay if gate is pushed UP from closed limit, used with clutch option. Also ANTI TAIL-GATE ALARM, if tailgating is detected by close loop, K1 relay will fire. When using clutch option, turning on S1-6 & S2-7, gate will close by timer whenever forced up. SWITCH 7: Used to enable arm to work in reverse direction, see page 9. SWITCH 8: Off will make K1 relay activate during open cycle (use with buzzers, counters, etc. ). On will pulse K1 relay when OPEN LIMIT (OLS) is reached (activates a swing or slide gate its lane). See also page 18, RELAY OUTPUT-K1
Shows Default Settings
1/8ths Seconds
1 - - - - 2 - - - - 4 - -- - -8
S1
ON
OFF OFF OFF OFF OFF OFF OFF OFF
Switch in OFF position
12345678
Fast Run Timer 1-4
FAST RUN TIMER - SWITCH PACK S1 (1-4)
C18 C15
The fast run timer sets the time that the operator runs at full speed. The slow stop ramp time is fixed but can be overrun by the fast run time if not adjusted properly. When adjusting make sure the slow stop ramp completes before the close limit. Changing settings will adjust fast run timer by 1/8 second increments. #2 and #4 on equals 1. 25 seconds, etc. )
1
1
J2
D8 S1 R1
MANUAL M/S
1
2
3
4
5
6
7
8
9
1Ø 11 12
AUX LIMITS
D1Ø
1 2 3 4 5 6 7 8
J3
6 7 8
Q2 OPEN R14 R18 R17 S3
J5
U18 T2 T1 D15 D16 D17 T4 T3 D18 D19 T6 T5 D22 T8 T7 D23 D24 R61
R53
S2 R12
1
2
3
4
5
R16 C3 C19 U4
CLOSE R21
OPEN 1 OPEN 2 OPEN 3
AUX 4 SAFETY 5 CLOSE 6 BACK 7SHADOW 8
C16
R24
R3Ø
R35
R36
R41
R42
R46 U13
R47
R5Ø U14
U8
U9
U11
U15
F5 C2
C1
U1
C2
R23 OLS D7 OPEN D6 BRAKE D5 CLOSE D4 R7 CLS D3 R6 IRD D2 R5 U2 R19 + C5 + R2 K1 R11 HBEAT D11 U19 Aux Relay BAT LO AC POWER D14 R13 BAT MOV D12 B1 R2Ø R15 R4 R3 Q1 D9 U3 C4 CPU R1Ø R9 R8 U5 U7 X2 X1 U6 R22 R26
R34 R33
R4Ø R39
R45 R44 R43 D21
R49 R48 R43
R6Ø C22 R59
IRD1
C7 C6
R63
R58 D27 DX3
R25 C12 U12 U1Ø
U16
Q6 Q5
DX4 R57 C13 R56 R38 R37 D2Ø R51 DX2
D29
JP2
Q4 D28
CLOSE TIMER - SWITCH PACK S2 (1-5)
NOTE: Default setting is off. On the MEGA ARM the switches 1-5 on S2 are for the closing time delay to select the period of time that the gate stays open after the obstruction sensor has reversed and re-opened the arm or if the S2-7 timer to close is turned on. The default will keep the gate up for 4 seconds to allow the vehicle to be moved from the gate arm path. Changing settings 1 - 5 will increase or decrease this hold open time. The default of 3 ON and 1, 2, 4, 5 OFF will provide a 4 second close time delay.
F2 1A DC F1 F4 F3
C8 C2Ø +
R55
D1
WARNING FOR R62 CONTINUOUS PROTECTION AGAINST FIRE DX1 REPLACE ONLY WITH THE SAME TYPE AND RATING OF FUSE
D25 D26
J4
1
MOTOR
TR
J1
1
C NC NO DC
B2 +
PWR
ACC+
ACC
BAT
BAT+
24VAC XFMR
MOTOR
Seconds
1--
2--
4--
8--
16
Shows Default Settings
MODE SELECTIONS - SWITCH PACK S2 (6-8)
SWITCH 6 - INPUT MEMORY: Activates multiple vehicle memory at auxiliary input terminal #4 on J5. (WARNING: Special care should be used to avoid arm from closing on cars. Use safety loops, stop loops, photo beams and a long enough time delay. ) NOTE: Can be used with multiple vehicle memory buffer to allow gate to close and reset count memory to zero. When using clutch option, turning on S1-6 & S2-7, gate will close by timer whenever forced up. SWITCH 8 - AUTO OPEN ON POWER FAILURE: When switch number 8 is in the ON position, the operator will automatically open the gate approximately 15 seconds after the loss of power. [. . . ] Aluminum Arm: 12' x 3" diameter with reflective yellow/black stripes. Round Padded Arm: 12' x 4" diameter, yellow (requires MA031). Round Padded Arm: 14' x 4" diameter, yellow (requires MA031). Aluminum Gate Arm: 15' x 3" with yellow/black stripes (requires MA117). [. . . ]