User manual HILTI X-FCM
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HILTI X-FCM. We hope that this HILTI X-FCM user guide will be useful to you.
Manual abstract: user guide HILTI X-FCM
Detailed instructions for use are in the User's Guide.
[. . . ] Direct Fastening Systems
X-FCM & X-FCP Grating & Checkerplate 3. 6 3. 6. 4 Installation Instructions
Threaded stud placing X-CRM8-15-12 h ET = 12 ± 2 mm hNVS = 18 ± 2 mm t II 6 mm Tightening torque Tmax = 4. 5 ft-lb (6. 1 N-m) for X-CRM8 and EM8 studs. [. . . ] grating height = L + 7
hhNVS NVS
hET hnom
th II
Governing requirement: · Minimum 2 mm clearance between X-FCM and surface of base steel to allow for deflections Governing requirement: · Minimum 5 mm thread engagement at the minimum allowable standoff, hNVS. The maximum grating height for an X-FCM type can be extended if hNVS is tightly controlled, e. g. at 18 mm instead of 16 mm.
EM8-15-14 hnom = 14 ± 2 mm hNVS = 18 ± 2 mm t II 6 mm
2
Example: X-FCM 25/30 Min. = 23 + 7 = 30mm
hhET nom
Note: ·
hhNVS NVS
Grating height of 32 can be accommodated if hNVS 18 mm
X-BT M8-15-6 SNR12 hNVS = 15. 7 - 16. 8 mm t II 8 mm
th II
Installation procedure for bar grating 1. Tighten the disk, without exceeding maximum tightening torque
t II
hNVS
30
hNVS NVS
1 Reference Section 3. 5. 4 for more details on proper installaton of X-BT fasteners.
Hilti, Inc. (US) 1-800-879-8000 | www. us. hilti. com I en español 1-800-879-5000 I Hilti (Canada) Corp. [. . . ] 1-800-363-4458 I www. ca. hilti. com I Product Technical Guide 2006 47
L
DX 750
1234
R [. . . ]