User manual SCOTSMAN FM2400RL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SCOTSMAN FM2400RL. We hope that this SCOTSMAN FM2400RL user guide will be useful to you.


SCOTSMAN FM2400RL : Download the complete user guide (726 Ko)

Manual abstract: user guide SCOTSMAN FM2400RL

Detailed instructions for use are in the User's Guide.

[. . . ] Double System RL TO THE OWNER OR USER: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain and service this ice system. It is designed to be connected to the condensing section of a refrigeration system, specifically a supermarket system. Table of Contents FOR THE INSTALLER: Specifications FOR THE INSTALLER . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FOR THE ELECTRICIAN . FOR THE INSTALLER: Final Check List INITIAL START UP . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Drain the reservoir and thoroughly wash the interior of the reservoir and cover with sanitizer solution. Continue ice making for at least 15 minutes, to flush out any cleaning solution. Add warm water to the ice storage bin and thoroughly wash and rinse all surfaces within the bin. Sanitize the bin interior by washing the interior of the bin with the balance of the sanitizer solution. Slowly pour the cleaning solution into the water reservoir until it is full. As the ice maker begins to use water from the reservoir, continue to add more cleaning solution to maintain a full reservoir. After all of the cleaning solution has been added to the reservoir, and the reservoir is nearly empty, switch the master switch to OFF. After draining the reservoir, as in step 6, wash and rinse the water reservoir. March 1997 Page 14 Double System RL MAINTENANCE SLIDE ICE LEVEL CONTROLS OUT OF CHUTE Electrical Shock Hazard Electrical shock can cause personal injury. The bin control uses devices that sense light, therefore they must be kept clean enough so that they can "see". At least twice a year, remove the bin control sensors from the base of the ice chute, and wipe the inside clean, as illustrated. The ice machine senses water level by a probe located in the water reservoir. At least twice a year, the probe should be removed from the reservoir, and the tip wiped clean of mineral build-up. CLEAN THE ICE LEVEL CONTROL SENSORS Inspect the assembly, looking for wear. Check and tighten all bolts and screws. RESERVOIR ICE SWEEP CLEAN THE WATER LEVEL SENSOR ///////////////////////////// CAUTION: THE TIMP IS MADE OF GLASS /////////////////////////////// BREAKER COVER 3. The bearing in the breaker should also be checked at least two times per year. Check the bearing by: ·pushing the bail clamp back and removing the ice chute cover ·unscrewing the ice sweep ·unscrewing the breaker cover ·unscrewing the auger stud March 1997 Page 15 Double System RL CLEANING In some installations the water supply to the ice maker will be so concentrated with dissolved minerals, (such as calcium carbonate) that as ice is made, the evaporator and auger become coated with the minerals, requiring a more frequent cleaning than twice per year. If in doubt about the condition of the evaporator and auger, the auger can be removed so the parts can be inspected. Note: Water filters can filter out suspended solids, but not dissolved solids. Check with a water treatment specialist regarding water treatment. DIVIDER, AUGER AND SLOTTED COLLAR ALLEN HEAD SCREWS Switch off electrical power, and shut off the water supply. For more information on removal of these parts, see REMOVAL AND REPLACEMENT. If top panel cannot be removed, or if there is less than 6" clearance over the top of the machine, the gearmotor/evaporator may be slid out for service access. Loosen band clamp under ice chute, and remove ice chute from evaporator. Allow the auger to dry, the stainless steel of the auger and evaporator must be clean and bright. [. . . ] Install auger, breaker, breaker bearing assembly, and ice discharge chute in reverse order DRIP PAN of disassembly. See "To Reassemble Evaporator and Auger" DIVIDER/BREAKER March 1997 Page 22 Double System RL REMOVAL AND REPLACEMENT: Gearmotor To Remove and Repair the Gearmotor Assembly: (Assuming that the procedures through removal of the water seal have been performed. ) 1. Unscrew the 4 cap screws holding the gearmotor to the gearmotor plate. A) Remove the cap screws holding the gearmotor case halves together and pry the two cases apart. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCOTSMAN FM2400RL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SCOTSMAN FM2400RL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.