Detailed instructions for use are in the User's Guide.
[. . . ] FM2402R
INTRODUCTION
To the owner or user: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain, and service this ice system. It features: front service for the freezer, gearmotor, control box, water reservoir, and bin control; an electronic circuit for monitoring ice and water level; a thermostatic expansion valve; and R-22 as the refrigerant.
TABLE OF CONTENTS
For the Installer Specifications . 35
Parts Lists and Wiring Diagrams are located in the center of this manual, printed on yellow paper.
December, 1992 Page 1
FM2402R
FOR THE INSTALLER
The FM2402R is designed to fit the following Scotsman storage bins: · B90 and extentions, with bin top KBT18. When installing a new system, check to be sure that you have everything you need before beginning: · Correct Bin · Correct Ice Machine · Correct Bin Top · All kits, legs, and information required for the specific job.
TOP VIEW Allow 6" of space behind the machine for utility connections.
18. 28" Ice Chute 6. 7" x 6. 2"
13. 84" 34. 84" BACK VIEW Liquid Line Connection (right system) 21" 3. 1" Discharge Line Connection (left system) Allow 6" above machine for service.
There are two separate ice making and refrigeration systems in this model. [. . . ] Check the breaker bearing by: · removing the ice chute cover · unscrewing the ice sweep · removing the water shed · unscrewing the breaker cover (left hand thread) · unscrewing the auger stud
BREAKER COVER
December, 1992 Page 22
FM2402R
MAINTENANCE AND CLEANING
In some areas the water supply to the icemaker will have a great deal of minerals in it, and that will result in an evaporator and auger becoming coated with these minerals, requiring a more frequent removal than twice per year. If in doubt about the condition of the evaporator and auger, the auger can be removed so the parts can be inspected. Note: Water filters can filter out suspended solids, but not dissolved solids. Check with a water treatment specialist regarding water treatment
For more information on removal and replacement of these parts, see REMOVAL AND REPLACEMENT. Remove 3 hex studs holding ice chute cover to ice chute, and remove cover. Loosen band clamp under ice chute, and remove ice chute from evaporator. After the auger has been removed, allow the auger to dry; if the auger is not bright and shiny, it must be cleaned. Reverse to reassemble.
ALLEN SCREWS
BREAKER & BEARING & AUGER ASSEMBLY
December, 1992 Page 23
FM2402R
SERVICE DIAGNOSIS: Condition - No Ice Being Produced
STATUS: NOTHING OPERATES
A. Check: The 2 reset switches (spout and high pressure): depress and release each switch. If the unit still does not start, check the spout switch, or high side pressure. Check the high pressure cut out switch, if closed, go to E; if open:
1. Check the high side pressure, reset the switch and observe that the fan is forcing air through the condenser. If the pressures rise above the trip out point, and the unit shuts down: a. If the air flow is poor because of the installation, advise the user that the unit should be moved, or the air around it kept cooler. Check that the fan blades are clean, and the fan secure to the fan motor shaft. Check the head pressure control valve, it should be maintaining a head pressure above 220 psig. If the unit has the correct charge, and the condenser is clean, and the refrigerant lines are not kinked or twisted, and the condenser is not overheated by external heat loads, the head pressure should be under the trip out point of the head pressure control switch. If all of the above are found to be good, and the machine trips out on high head pressure, replace the head pressure control valve.
E. This switch will open if the bin control (ice level sensor) does not shut the machine off when the ice storage bin is full of ice: ice backs up in the ice chute, and internal pressure opens the switch, stopping the machine. After the ice melts, the switch will reset but the machine will not restart until the reset switch in the control box is pressed. If there is not enough water in the reservoir, the water level sensor will keep the machine from starting.
a. If the machine does not start, see the next page.
December, 1992 Page 24
FM2402R
SERVICE DIAGNOSIS: Condition - No Ice Being Produced
STATUS: NOTHING OPERATES
G. [. . . ] There are various mechanical devices that may be used to recycle refrigerant at the field level, however, Scotsman requires that any refrigerant placed into a Scotsman ice machine meet ARI spec 700-88. Use conservation minded service procedures: · Refrain from checking refrigeration pressures without reason. There are many ways to determine the proper operation of a Scotsman ice machine without using refrigerant gauges. Visual inspection of the water system, observation of the ice formation, amp draw, voltage, and other techniques will lead to proper diagnosis. [. . . ]