[. . . ] AY-XP09DR-N
OPERATION MANUAL
· Uses ozone layer friendly refrigerant R410A.
INDOOR UNIT
OUTDOOR UNIT
AY-XP09DR-N AE-X09DR-N
ENGLISH
SPLIT TYPE ROOM AIR CONDITIONER
ENGLISH
CONTENTS
· PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 · SETTING DEODORANT DUST COLLECTING FILTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5 · USING THE REMOTE CONTROL . . . . . . . . . . . E-12 · TIPS ABOUT PLASMACLUSTER OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-20
PRECAUTIONS
WARNINGS FOR USE
1 2 3 4 5 6 7 8
Do not pull or deform the power supply cord. [. . . ] · In the COOL and HEAT modes, the temperature can be set within the range of 18 to 32°C
(Example: 1°C higher)
1
MODE
1h
C
(Example: 2°C lower)
CLEAN FAN SWING SET/C
4
C
4
Press the FAN button to set the desired fan speed.
AUTO SOFT LOW HIGH
· In the DRY mode, the fan speed is preset to AUTO and cannot be changed.
5
To turn off the unit, press the ON/OFF button again.
· The red OPERATION lamp ( will turn off. ) on the unit
E-8
TIPS ABOUT AUTO MODE
In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature and outdoor temperature when the unit is turned on.
Modes and Temperature Settings
0 29 21 (¡C) 10 18 Cool (24¡C) Heat Heat (24¡C) (23¡C) Dry ( Room Temp. ) -2¡C Heat (22¡C)
the figures in ( ) are temperature settings
28
34 temp. (¡C)
outdoor
Cool Cool (25¡C) (26¡C)
indoor temp.
During operation, if the outdoor temperature changes, the temperature settings will automatically slide as shown in the chart.
TIPS ABOUT INDICATOR PANEL
The indicator panel will change each time you press the DISPLAY button in the following manner.
DISPLAY
temperature Indiactor
Room Temp. The outdoor temperature is displayed.
temperature Indiactor
Outdoor Temp. Lamp
No display.
NOTES:
· The displayed temperatures are rough estimates and may vary from the actual temperatures. · Temperature display ranges Room temperature: 0°C ~ 40°C ( is displayed when less than 0°C and when higher than 40°C) Outdoor temperature: -9°C ~ 45°C ( is displayed when less than -9°C and when higher than 45°C) · is displayed during the first 60 seconds of operation while the temperatures are being detected. · The temperature display will go off.
AM
TO CANCEL
Press the FULL POWER button again.
· FULL POWER operation will also be cancelled when the operation mode is changed, or when the unit is turned off.
DISPLAY
1
NOTE:
· You can not set the temperature and fan speed during the FULL POWER operation.
E-11
ONE-HOUR OFF TIMER
When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour.
1 Press the ONE-HOUR OFF TIMER button.
· The remote control displays " ". · The unit will stop operating after one hour.
TO CANCEL
Press the TIMER CANCEL (SET/C) button.
MODE
1h
1
· The orange TIMER lamp (
) on the unit will turn off.
Or, turn the unit off by pressing the ON/OFF button.
· The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off.
CLEAN FAN
NOTES:
· The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations. · When the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour with the formerly set condition. · If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER activates, press the ONE-HOUR OFF TIMER button again during operation. · If TIMER ON and/or TIMER OFF are set, TIMER CANCEL button cancels every setting.
TIPS ABOUT PLASMACLUSTER OPERATION
The Plasmacluster Ion generator inside the air conditioner will release Plasmacluster ions, which are collective mass of positive and negative ions, into the room. The Plasmacluster ions reduce airborne mold fungus.
AIR CLEAN OPERATION
Plasmacluster ions released into the air will reduce airborne mold fungus.
ION BALANCE OPERATION
Plasmacluster Ion generator Plasmacluster ions
It is said that plenty of negative ions exist in places such as waterfalls or waterside in natural environment. In this operation mode, negative ions will be released in an increased rate, in order to bring the room air close to this condition.
SELF CLEAN OPERATION
Plasmacluster Operation will be performed with FAN or HEAT mode, in order to reduce the growth of mold fungus, and dry inside of the air conditioner unit. Mold fungus already grown can not be eliminated by this operation.
E-12
PLASMACLUSTER OPERATION
You can choose AIR CLEAN OPERATION or ION BALANCE OPERATION
1 During operation, press the PLASMACLUSTER button to select the mode.
AIR CLEAN REMOTE CONTROL DISPLAY PLASMACLUSTER lamp on the unit ION BALANCE CANCEL BLUE lamp light up GREEN lamp light up Lamp goes off
1
DISPLAY
· In the AIR CLEAN operation, the blue PLASMACLUSTER lamp on the unit will light up. · In the ION BALANCE operation, the green PLASMACLUSTER lamp on the unit will light up.
TO CANCEL
Press the PLASMACLUSTER button until PLASMACLUSTER symbol on the remote control display goes off.
NOTES:
· The PLASMACLUSTER lamp on the unit will turn off.
· Setting of the PLASMACLUSTER operation will be memorized and will operate in the same mode, the next time you turn on the air conditioner. · To turn off the PLASMACLUSTER lamp, press the DISPLAY button. · When the PLASMACLUSTER button is pressed while the unit is not operating, the PLASMACLUSTER operation will be performed without accompanying air conditioning mode (eg, HEATING or COOLING). The mode symbol of the remote control will go off and the fan speed can not be set AUTO.
SELF CLEAN OPERATION
1 Press the SELF CLEAN button when the unit is not operating.
· The remote control displays " ". · The red OPERATION lamp ( ) and the blue PLASMACLUSTER lamp on the unit will light up. · The remaining operation time will be indicated on the TEMPERATURE INDICATOR of the indoor unit in minute decrements.
MODE
1h
TO CANCEL
CLEAN FAN
1
Press the SELF CLEAN button. Or, turn the unit off by pressing the ON/OFF button.
· The red OPERATION lamp ( ) and the blue PLASMACLUSTER lamp on the unit will turn off.
NOTE:
· You cannot set the temperature, fan speed, air flow direction or timer setting during the SELF CLEAN operation.
E-13
ENGLISH
TIMER OPERATION
NOTE:
Before setting the timer, make sure the clock is properly set with the current time.
TIMER OFF
) button. 1 Press the TIMER OFF ( 2 The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. [. . . ] 2 Put the shaft at the left of the louvre in the shaft receiver of the unit. Make sure the shaft at the center of the louvre is placed in the center shaft receiver of the air outlet. 3 Close the left cover until it clicks.
Hole
1
Shaft Shaft Receiver
2
2
5 Connect the poweroncord to the wall outlet or turn the circuit
breaker.
3
Cover
E-18
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
INDOOR TEMP. · The built-in protective device may prevent the unit from operating when used out of this range. [. . . ]