User manual SMEG SGR20S
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SMEG SGR20S. We hope that this SMEG SGR20S user guide will be useful to you.
You may also download the following manuals related to this product:
SMEG SGR20S (551 ko)
SMEG SGR20S (561 ko)
Manual abstract: user guide SMEG SGR20S
Detailed instructions for use are in the User's Guide.
[. . . ] According to the intended use , the CE symbol was affixed on the basis of the EU Directives named below: 89/336/EEC, 98/37/EEC and 73/23EEC amended by 93/68EEC. The 93/42EEC Directive is not applicable to bonding and sealing devices. [. . . ] Heavy dust, vapour, dripping or spraying water have a negative effect on the machine functions. Always ensure that the operating power corresponds to the specifications on the machine rating plate.
F
Please choose a socket where the line power is stable.
Œ Leave a gap of 200 mm between the device and the wall. •
Please do not transport device on the peel edge setting!
200 mm
•
Œ
GB 5
9. 696. 037
ENGLISH
SGR20S
Before Starting
3
Start-Up
l Plug power cable into power socket on machine l Insert plug into wall socket l Switch on machine with power switch
Power switch
Switch conection
FUNCTION Machine switched on Self-test runs for approx. 5 seconds: V2. 8 = Program version 956579 = Machine number Display of date, time Actual temperature. Setemperature After 5 minutes is the set temperature reached Machine is ready for operation
Control 800 956579 17-02-00 14:30 Nominal temp 17-02-00 14:35
V2. 8
025°C 140°C 140°C
GB 6
9. 696. 037
ENGLISH
SGR20S
Basic Functions
4
DISPLAY
Programming Aids
FUNCTION INPUT AIDS Cursor control Press - cursor right - key once KEYS Cursor left Cursor right
100°C
5 Cursor flashes at 1 st digit
10 0°C
1x
INPUT AIDS Changing numbers and letters Press key - position +1 - once INPUT AIDS Return to previous menu point without activating entry INPUT AIDS Activate input INPUT AIDS Space at selected point Set piece counter to 0 Position +1Position -1
5 Cursor flashes at 2 nd digit
100°C
51 st digit is number 1
200°C
1x
5 1 st digit is number 2
9. 696. 037
GB 7
ENGLISH
SGR20S
Basic Functions
KEYS DISPLAY
4
Configuration
FUNCTION CONTRAST SETTING è Contrast é Contrast ê DATA INPUT Selection: Language, symbols, temperature unit Language: DE, GB, FR, ES, IT, FI, SE, PL Symbols: yes/no yes / no Temperature unit: C / F Celsius / Fahrenheit
display - contrast
è
Language selection
set language GB pictogramm temperature unit C NO
Printer Set-Up
FUNCTION PRINTER SET UP è Yes / No Input Input Start printing KEYS DISPLAY
printer set up YES
Start printing 0 - 99 mm
distance 00
0-99mm
Character width 0-5 Input Character width
character width 0
0-5
GB 8
9. 696. 037
ENGLISH
SGR20S
Basic Functions
4
DISPLAY
Data Input
FUNCTION TEMPERATURE Nominal temperature input 80 - 220 °C / 176 - 428 ° F DATA INPUT Date and time Input of 6 different date formats 1 dd-mm-yyyy 2 mm-dd-yyyy 3 yyyy-mm 4 mm-yyyy 5 yyyy 6 yyyy-mm-dd DATA INPUT Expiration date Enter 3 differnt expiration dates,
ex works: 1= Date + 1 Month 2= Date + 3 Month 3= Date + 6 Month
KEYS Input Temperature
nominal temp. 175°C format date & time DD-MM-YYYY DD-MM-YY hh:mm 17-02-2000 08:57
è
ê
1, 2, 3, 4, 5, 6
Input date, time
ê Input Expiration date Input Charge number Input Personnel number Input Piece Counter Input Text
DD-MM-YYYY 17-03-2000
1
1, 2, 3
DATA INPUT Charge number 10-digit, alphanumerical DATA INPUT Personnel number 20-digit, alphanumerical DATA INPUT Piece counter 7-digit, numerical DATA INPUT Text 20-digit, alphanumerical
1234567890 0987654321 piece counter 1234567 text input SMEG
9. 696. 037
GB 9
ENGLISH
SGR20S
Basic Functions
4
Data Activation / Deactivation
FUNCTION Print: Sterlization date, Expiry date, Personnel number The print sequence is predefined, this means the individual information like Sterlization date Expiry date Charge number Personnel number Piece counter Text get always print in the same sequence
17-02-2000
17-03-2000
Miller
Print: Sterlization date, Personnel number
17-02-2000
Miller
FUNCTION PRINT Sterilization date
KEYS Print Do not print
DISPLAY
17-02-2000
PRINT Expiration date Selection of 3 different expiration dates Print Do not print
ê
17-03-2000
1
1, 2, 3
PRINT Charge number Print Do not print
1234567890
PRINT Personnel number Print Do not print
0987654321
PRINT Piece counter Print Do not print
piece counter 12345
Print Do not print
PRINT Text
text input SMEG
GB 10
9. 696. 037
ENGLISH
SGR20S
Basic Functions
4
DISPLAY
Special functions
FUNCTION PRINT Printer OFF/ON DISPLAYS Absolute part counter è DISPLAYS Operating time counter è KEYS
17-02-2000 14:30 printer off absolute p. counter 1234567 operating time 000053 h 25 min
180°C
9. 696. 037
GB 11
ENGLISH
SGR20S
Basic Functions
4
Operation
Sealing Operation l Adjust peeling edge width After loosening the arrest the peeling edge can be adjusted infinitely between 5 mm and 30 mm by moving the plate. l Insert sterilization package The drive is switched on automatically. l Removed sealed sterilization package and allow to cool briefly.
F
Check strength by tearing open seal. If the paper discolors or the foil peels off the temperature is too high.
Determine suitable sealing temperature with sealing tests.
GB 12
9. 696. 037
ENGLISH
SGR20S
Troubleshooting and Maintenance
5
Troubleshooting Chart
Malfunction Possible cause Power connection
Power cable not plugged in
Remedy
Check power connection, if necessary connect to different socket. Replace control board Replace display board Increase nominal temperature Reset temperature limiter by pressing in pin !If temperature limiter trips again always have machine checked Replace temperature sensor Check heating cartridges, replace if necessary Replace control board Replace light barrier
Machine cannot be switched on No data on display
Power cable defective
Power fuse
Control board Display board Nominal temperature too low Temperature limitation active
Machine does not heat up Temperature sensor Heating cartridge Control board Motor sensor Front flap not closed
No transport
Close front flap
Front flap - sensor Transport belt Damaged No transport Motor Control board
Replace front flap sensor Replace transport belt Check belt tension
Replace motor
Replace control board
9. 696. 037
GB 13
ENGLISH
SGR20S
Troubleshooting and Maintenance
5
Troubleshooting Chart
Malfunction Possible cause Transport belt guide Remedy
Replace PTFE belt on guide die
Material feed not uniform or Transport belt loud running noise Damaged No transport Motor Temperature
too low
Replace transport belt Check belt tension
Replace motor
Increase temperature Readjust pressure of sealing roller or replace sealing roller
Seal does not hold
Pressure too low
Sealing seam distorted Paper side of package discolored or side fold shrunk No imprint or imprint incomplete
Pressure too high Temperature too high Programming
Start of print not correctly adjusted
Loosen upper guide die and readjust downward Reduce temperature
Reprogram start of print
Ink ribbon Printer head Control board Imprint too weak Ink ribbon Print head Paper hold-down Keyboard does not work Keyboard
Ink ribbon not correctly installed Replace ink ribbon Replace print head Replace control board
Replace ink ribbon. Readjust print head.
Replace pressure spring for paper hold-down Check keyboard connector for good contact. Replace control board
Display board Control board
GB 14
9. 696. 037
ENGLISH
SGR20S
Troubleshooting and Maintenance
5
Maintenance Chart
As all technical equipment your equipment is also subject to technical wear. [. . . ] 30 s Select language Language: German, English, French, Spanish, Italian SYSTEM CALIBRATION
+
+
Please wait
Language selection
Set language GB system calibration next key
Time 1 Temperature 1
Temperature TEMPERATURE
Printer
After reaching T=120 °C / 248 °F: Enter measured temperature 1 after waiting 120 sec.
Input temperature 1
120 reading :
Time 2
120°C °C
Temperature 2
Measure temperature between printing dies
After reaching T=200 °C / 392 °F: Enter measured temperature 2 after waiting 120 sec.
Input temperature 2
120 reading :
200°C °C
PRINTER 1. Measure distance 1 and 2 Bottom of specimen
Confirm test printout
printer calibration test print printer calibration distance 1 printer calibration distance 2 mm mm
Input distance 1
Distance 1
Distance 2
Input distance 2
Switch off machine
9. 696. 037
GB 23
ENGLISH
SGR20S
Technical Data
6
Stand by function
Switch off machine All 3 keys together
+
Switch on machine Self-test runs for approx. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG SGR20S
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG SGR20S will begin.